Shangheng STF JC3.5FE Oil Differential Pressure Control with 60-Second Delay

Sale price $22.00

Go kalles this summer with this vintage navy and white striped v-neck t-shirt from the Nike. Perfect for pairing with denim and white kicks for a stylish kalles vibe.

Model: JC3.5FE
Add to Wishlist
Add to Compare

Shangheng STF JC3.5FE Oil Differential Pressure Control with 60-Second Delay

Shangheng STF JC3.5FE Oil Differential Pressure Control with 60-Second Delay

PRODUCT DESCRIPTION

The Shangheng STF JC3.5FE is a mechanical oil differential pressure control designed to protect refrigeration compressors equipped with forced-lubrication oil pumps.

It monitors the effective oil pressure difference between the oil-pump outlet and the compressor crankcase. If sufficient differential oil pressure is not established or remains below the set value for 60 seconds, the control initiates a protective shutdown to help prevent compressor damage caused by insufficient lubrication.

The control features an adjustable differential pressure range and manual reset. It is suitable for compatible commercial and industrial refrigeration compressors, condensing units and cold-storage systems.

KEY FEATURES

• Mechanical oil differential pressure monitoring
• Adjustable differential pressure range from 0.5 to 3.5 bar
• Factory setting of approximately 1.0 bar
• Fixed 60-second safety delay
• Manual reset following a protective trip
• Maximum working pressure of 16 bar
• Compatible with AC 220 V and AC 380 V control circuits
• Designed for compressors with forced-lubrication oil pumps
• High- and low-pressure connections for direct oil-pressure monitoring

TECHNICAL SPECIFICATIONS

Parameter Specification
Listed Model JC3.5FE
Published Product Family JC3.5
Product Type Mechanical Oil Differential Pressure Control
Differential Pressure Adjustment Range 0.5–3.5 bar
Factory Set Point 1.0 bar / 0.1 MPa
Maximum Working Pressure 16 bar
Safety Delay Time 60 seconds
Rated Control Voltage AC 220 V / AC 380 V
Contact Capacity 300 VA
Reset Method Manual reset
High-Pressure Connection Lubricating oil-pump outlet
Low-Pressure Connection Compressor crankcase or low-pressure reference
Main Application Compressor lubrication protection
Brand Shangheng / STF Controls
Manufacturer Shanghai Thermostat Factory Co., Ltd.

OPERATING PRINCIPLE

The controller measures the difference between:

Oil-pump outlet pressure − compressor crankcase pressure

This value represents the effective lubricating oil pressure available to the compressor.

If the pressure difference remains below the selected set point for 60 seconds after compressor start-up or during operation, the control activates the protective shutdown circuit. The cause of insufficient oil pressure must be identified and corrected before restarting the compressor.

INSTALLATION NOTES

• Install the controller in a location with minimal vibration.
• Connect the high-pressure port to the lubricating oil-pump outlet.
• Connect the low-pressure port to the compressor crankcase or specified low-pressure reference.
• Complete electrical wiring according to the terminal diagram and selected supply voltage.
• Installation and commissioning must be performed by a qualified refrigeration technician.
• After a protective trip, investigate the lubrication fault before resetting the controller.
• According to the manufacturer’s instructions, wait at least five minutes before resetting after a system trip.
• Confirm compatibility with the compressor, oil pump and control circuit before ordering.

APPLICATIONS

• Semi-hermetic refrigeration compressors with oil pumps
• Commercial refrigeration condensing units
• Industrial refrigeration systems
• Cold-storage refrigeration systems
• Chillers and other compatible compressor systems