{"title":"Refrigeration Solenoid Valves","description":null,"products":[{"product_id":"magic-control-mgf-series-solenoid-valve","title":"Magic Control MGF Series Refrigeration Solenoid Valve for Cold Room and HVAC Systems","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003eMagic Control MGF Series Refrigeration Solenoid Valve\u003c\/h2\u003e\n\u003cp\u003eMagic Control MGF Series refrigeration solenoid valves are designed for automatic refrigerant flow control in refrigeration and air conditioning systems.\u003c\/p\u003e\n\u003cp\u003eThe valves are widely used in cold rooms, refrigeration units, condensing units and HVAC systems to control refrigerant circulation and improve system operation reliability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAvailable Models\u003c\/h2\u003e\n\u003ch3\u003eMGF20 Series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMGF20-2X\u003c\/li\u003e\n\u003cli\u003eMGF20-2XS\u003c\/li\u003e\n\u003cli\u003eMGF20-3X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMGF64 Series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMGF64-3X\u003c\/li\u003e\n\u003cli\u003eMGF64-3XS\u003c\/li\u003e\n\u003cli\u003eMGF64-4X\u003c\/li\u003e\n\u003cli\u003eMGF64-4XS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMGF70 Series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMGF70-4X\u003c\/li\u003e\n\u003cli\u003eMGF70-4XS\u003c\/li\u003e\n\u003cli\u003eMGF70-5X\u003c\/li\u003e\n\u003cli\u003eMGF70-5XS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMGF98 Series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMGF98-6X\u003c\/li\u003e\n\u003cli\u003eMGF98-6XS\u003c\/li\u003e\n\u003cli\u003eMGF98-7XS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMGF99 Series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMGF99-9XS\u003c\/li\u003e\n\u003cli\u003eMGF99-10XS\u003c\/li\u003e\n\u003cli\u003eMGF99-6N\u003c\/li\u003e\n\u003cli\u003eMGF99-7N\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003cbr\u003eRefrigeration Solenoid Valve\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003cbr\u003eMagic Control\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003cbr\u003eMGF Series\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCold Room Refrigeration\u003c\/li\u003e\n\u003cli\u003eCommercial Refrigeration\u003c\/li\u003e\n\u003cli\u003eIndustrial Refrigeration\u003c\/li\u003e\n\u003cli\u003eAir Conditioning Systems\u003c\/li\u003e\n\u003cli\u003eRefrigeration Equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003cbr\u003eElectromagnetic control of refrigerant flow in refrigeration circuits.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eProduct Features\u003c\/h1\u003e\n\u003cp\u003e✔ Reliable refrigerant flow control\u003cbr\u003e✔ Suitable for refrigeration and HVAC applications\u003cbr\u003e✔ Wide model range for different system requirements\u003cbr\u003e✔ Compact design and easy installation\u003cbr\u003e✔ Suitable for professional refrigeration systems\u003c\/p\u003e","brand":"Magic Control","offers":[{"title":"MGF20-2X","offer_id":43921029398587,"sku":null,"price":12.0,"currency_code":"USD","in_stock":true},{"title":"MGF20-2XS","offer_id":43921029431355,"sku":null,"price":12.0,"currency_code":"USD","in_stock":true},{"title":"MGF20-3X","offer_id":43921029464123,"sku":null,"price":12.0,"currency_code":"USD","in_stock":true},{"title":"MGF64-3X","offer_id":43921029496891,"sku":null,"price":16.0,"currency_code":"USD","in_stock":true},{"title":"MGF64-3XS","offer_id":43921029529659,"sku":null,"price":16.0,"currency_code":"USD","in_stock":true},{"title":"MGF64-4X","offer_id":43921029562427,"sku":null,"price":16.0,"currency_code":"USD","in_stock":true},{"title":"MGF64-4XS","offer_id":43921029595195,"sku":null,"price":16.0,"currency_code":"USD","in_stock":true},{"title":"MGF70-4X","offer_id":43921029627963,"sku":null,"price":17.0,"currency_code":"USD","in_stock":true},{"title":"MGF70-4XS","offer_id":43921029660731,"sku":null,"price":17.0,"currency_code":"USD","in_stock":true},{"title":"MGF70-5X","offer_id":43921029693499,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"MGF70-5XS","offer_id":43921029726267,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"MGF98-6X","offer_id":43921029759035,"sku":null,"price":29.0,"currency_code":"USD","in_stock":true},{"title":"MGF98-6XS","offer_id":43921029791803,"sku":null,"price":29.0,"currency_code":"USD","in_stock":true},{"title":"MGF98-7XS","offer_id":43921029824571,"sku":null,"price":30.0,"currency_code":"USD","in_stock":true},{"title":"MGF99-9XS","offer_id":43921029857339,"sku":null,"price":52.0,"currency_code":"USD","in_stock":true},{"title":"MGF99-10XS","offer_id":43921029890107,"sku":null,"price":53.0,"currency_code":"USD","in_stock":true},{"title":"MGF99-6N","offer_id":43921029922875,"sku":null,"price":39.0,"currency_code":"USD","in_stock":true},{"title":"MGF99-7N","offer_id":43921029955643,"sku":null,"price":42.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-10_132932_570.png?v=1786340583"},{"product_id":"stf-fdf-series-refrigeration-solenoid-valve","title":"STF FDF-MG High-Pressure ODF Refrigeration Solenoid Valves","description":"\u003ch3\u003e\u003cspan\u003ePRODUCT DESCRIPTION\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSTF FDF-MG series solenoid valves are high-pressure, servo pilot-operated refrigeration valves developed for R410A systems and other compatible HFC and HCFC refrigerants.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe series uses ODF solder connections and is designed for automatic control of refrigerant flow in liquid, suction and hot-gas lines. Its 45-bar maximum working pressure makes it suitable for higher-pressure refrigeration and air-conditioning applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKEY FEATURES\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e• Developed for R410A and other compatible HFC and HCFC refrigerants\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Servo pilot-operated construction\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• ODF solder connections\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Suitable for liquid, suction and hot-gas applications\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Maximum working pressure of 45 bar\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Liquid-line test pressure of at least 68 bar\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Medium temperature from −40°C to +105°C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Maximum medium temperature of +130°C during defrosting\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Ambient temperature from −40°C to +55°C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• AC and DC coil options\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• UL and cUL versions available by order\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eGENERAL TECHNICAL DATA\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eValve Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eServo pilot-operated solenoid valve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eODF solder\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Working Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLiquid-Line Test Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥68 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMedium Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−40°C to +105°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Defrost Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+130°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−40°C to +55°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatible Refrigerant Families\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eR410A and compatible HFC\/HCFC refrigerants\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eValve Body Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBrass\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShanghai Thermostat Factory Co., Ltd.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShangheng \/ STF Controls\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eVERIFIED MODELS\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel and Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKv Value\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFDF6MG – 3\/8 in ODF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e127 × 32 × 80 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFDF8MG – 1\/2 in ODF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e137 × 38 × 88 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFDF10MG – 5\/8 in ODF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.8 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e166 × 45 × 88 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFDF15MG – 3\/4 in ODF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e174 × 52 × 96 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFDF15MG – 7\/8 in ODF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e174 × 52 × 96 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFDF25MG – 1 1\/8 in ODF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.8 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e236 × 72 × 119 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFDF32MG – 1 1\/8 in ODF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e281 × 86 × 133 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFDF32MG – 1 3\/8 in ODF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e281 × 86 × 133 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eAPPLICATIONS\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e• R410A air-conditioning systems\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Commercial refrigeration systems\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• High-pressure liquid lines\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Suction lines\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Approved hot-gas and defrost lines\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Heat-pump systems\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Condensing units\u003c\/span\u003e\u003c\/p\u003e","brand":"STF","offers":[{"title":"FDF6MG-3\/8","offer_id":43921787584571,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"FDF8MG-1\/2","offer_id":43921787617339,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"FDF10MG-5\/8","offer_id":43921787650107,"sku":null,"price":27.0,"currency_code":"USD","in_stock":true},{"title":"FDF15MG-3\/4","offer_id":43921787682875,"sku":null,"price":33.0,"currency_code":"USD","in_stock":true},{"title":"FDF15MG-7\/8","offer_id":43921787715643,"sku":null,"price":34.0,"currency_code":"USD","in_stock":true},{"title":"FDF19M1-9\/8","offer_id":43921787748411,"sku":null,"price":54.0,"currency_code":"USD","in_stock":true},{"title":"FDF19M4-9\/8","offer_id":43921787781179,"sku":null,"price":71.0,"currency_code":"USD","in_stock":true},{"title":"FDF25MG-11\/8","offer_id":43921787813947,"sku":null,"price":92.0,"currency_code":"USD","in_stock":true},{"title":"FDF32MG-11\/8","offer_id":43921787846715,"sku":null,"price":119.0,"currency_code":"USD","in_stock":true},{"title":"FDF32MG-13\/8","offer_id":43921787879483,"sku":null,"price":119.0,"currency_code":"USD","in_stock":true},{"title":"FDF40H-17\/8","offer_id":43921787912251,"sku":null,"price":207.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-09-07_170509_259.png?v=1788771967"},{"product_id":"stf-fdf-mbj-series-refrigeration-solenoid-valve","title":"STF FDF-MB and FDF-MBJ SAE Threaded Refrigeration Solenoid Valves","description":"\u003ch3\u003e\u003cspan\u003ePRODUCT DESCRIPTION\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSTF FDF-MB and FDF-MBJ solenoid valves are pilot-operated diaphragm valves designed for automatic refrigerant flow control in refrigeration, freezing and air-conditioning systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese compact brass valves use threaded SAE connections and are suitable for installation in liquid, suction and hot-gas lines, subject to the selected refrigerant, coil and operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNormally closed versions are commonly supplied. Normally open configurations are available for selected models. AC and DC coil options are available and must be confirmed when ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKEY FEATURES\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e• Pilot-operated diaphragm construction\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• SAE threaded refrigerant connections\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Suitable for liquid, suction and hot-gas lines\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normally closed and selected normally open versions\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Multiple AC and DC coil-voltage options\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Maximum working pressure up to 30 bar\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Medium temperature range from −25°C to +105°C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Compact brass valve construction\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Designed for refrigeration and air-conditioning systems\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eGENERAL TECHNICAL DATA\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eValve Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePilot-operated diaphragm solenoid valve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSAE threaded connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Working Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMedium Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−25°C to +105°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNC Opening Differential – AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.05–21 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNC Opening Differential – DC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.05–17 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNO Opening Differential – AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.05–18 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNO Opening Differential – DC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.05–15 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable AC Coils\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V, 36 V, 110 V, 220 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable DC Coils\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 V, 24 V, 110 V, 220 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eValve Body Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBrass\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShanghai Thermostat Factory Co., Ltd.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShangheng \/ STF Controls\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eVERIFIED MODEL DATA\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Port\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKv Value\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFDF8MB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 × 45 × 85 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFDF10MBJ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.9 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e87 × 45 × 85 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFDF13MBJ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e107 × 52 × 98 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eAPPLICATIONS\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e• Commercial refrigeration systems\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Cold-storage condensing units\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Refrigerated display equipment\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Air-conditioning systems\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Liquid-line control\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Suction-line control\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Hot-gas control where approved\u003c\/span\u003e\u003c\/p\u003e","brand":"STF","offers":[{"title":"FDF8MBJ","offer_id":43921849024571,"sku":null,"price":20.0,"currency_code":"USD","in_stock":true},{"title":"FDF10MBJ","offer_id":43921849057339,"sku":null,"price":23.0,"currency_code":"USD","in_stock":true},{"title":"FDF13MBJ","offer_id":43921849090107,"sku":null,"price":26.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-09-07_170509_259.png?v=1788771967"},{"product_id":"hongsen-hvd-piston-solenoid-valves","title":"HONGSEN HVD Series Piston Solenoid Valves for Refrigeration","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eHONGSEN HVD Series piston-operated solenoid valves are designed for one-way refrigerant flow in commercial and industrial refrigeration systems. They can be installed in liquid, suction-gas and hot-gas lines used in cold rooms, refrigeration equipment and air-conditioning systems.\u003c\/p\u003e\n\u003cp\u003eThe series covers connection sizes from 3\/8 inch to 1-5\/8 inch ODF. Complete valves with coils and replacement valve bodies without coils are available according to the selected model.\u003c\/p\u003e\n\u003cp\u003eThe piston-operated construction is suitable for refrigeration applications requiring reliable shut-off, high working pressure and a wide selection of flow capacities.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePiston-operated refrigeration solenoid valve\u003c\/li\u003e\n\u003cli\u003eNormally closed operation\u003c\/li\u003e\n\u003cli\u003eDesigned for one-way refrigerant flow\u003c\/li\u003e\n\u003cli\u003eODF solder connections\u003c\/li\u003e\n\u003cli\u003eSuitable for liquid, suction-gas and hot-gas lines\u003c\/li\u003e\n\u003cli\u003eValve body and coil can be supplied separately\u003c\/li\u003e\n\u003cli\u003eCompatible with specified HCFC and HFC refrigerants\u003c\/li\u003e\n\u003cli\u003eStandard AC 220V and AC 380V coil options\u003c\/li\u003e\n\u003cli\u003eOther coil configurations available by request\u003c\/li\u003e\n\u003cli\u003eStandard three-wire plug-type coil connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHONGSEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eHVD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve Type\u003c\/td\u003e\n\u003ctd\u003ePiston-operated solenoid valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Position\u003c\/td\u003e\n\u003ctd\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Direction\u003c\/td\u003e\n\u003ctd\u003eOne-way\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eODF solder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Refrigerants\u003c\/td\u003e\n\u003ctd\u003eSpecified HCFC and HFC refrigerants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium Temperature\u003c\/td\u003e\n\u003ctd\u003e−30°C to +105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Coil Voltage\u003c\/td\u003e\n\u003ctd\u003eAC 220V or AC 380V, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom Coil Voltage\u003c\/td\u003e\n\u003ctd\u003eAvailable by request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted Voltage Variation\u003c\/td\u003e\n\u003ctd\u003e+10% \/ −15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Connection\u003c\/td\u003e\n\u003ctd\u003eStandard three-wire plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid MOPD\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eTechnical values are based on the HONGSEN published HVD selection data. \u003c\/p\u003e\n\u003ch3\u003eModel Selection\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eMinimum ΔP\u003c\/th\u003e\n\u003cth\u003eLiquid MOPD\u003c\/th\u003e\n\u003cth\u003eMaximum Working Pressure\u003c\/th\u003e\n\u003cth\u003eKv\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVD8-3T\u003c\/td\u003e\n\u003ctd\u003e3\/8\" ODF\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003ctd\u003e0.8 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVD10-4T\u003c\/td\u003e\n\u003ctd\u003e1\/2\" ODF\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003ctd\u003e1.4 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVD10-5T\u003c\/td\u003e\n\u003ctd\u003e5\/8\" ODF\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003ctd\u003e1.9 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVD15-6T\u003c\/td\u003e\n\u003ctd\u003e3\/4\" ODF\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003ctd\u003e2.6 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVD25-9T\u003c\/td\u003e\n\u003ctd\u003e1-1\/8\" ODF\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003ctd\u003e10 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVD32-11T\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\" ODF\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003ctd\u003e16 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVD40-13T\u003c\/td\u003e\n\u003ctd\u003e1-5\/8\" ODF\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003ctd\u003e25 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAvailable Stock Configurations\u003c\/h3\u003e\n\u003cpre dir=\"ltr\"\u003e\u003ccode\u003eHVD8-3T — 3\/8 ODF — Valve Body Without Coil\nHVD10-4T — 1\/2 ODF — Valve Body Without Coil\nHVD10-5T — 5\/8 ODF — Valve Body Without Coil\nHVD15-6T — 3\/4 ODF — Valve Body Without Coil\nHVD25-9T — 1-1\/8 ODF — AC220V Complete Valve\nHVD32-11T — 1-3\/8 ODF — AC220V Complete Valve\nHVD40-13T — 1-5\/8 ODF — AC220V Complete Valve\u003c\/code\u003e\u003c\/pre\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCold-room refrigeration systems\u003c\/li\u003e\n\u003cli\u003eRefrigeration condensing units\u003c\/li\u003e\n\u003cli\u003eLiquid refrigerant lines\u003c\/li\u003e\n\u003cli\u003eCompressor suction lines\u003c\/li\u003e\n\u003cli\u003eHot-gas defrost lines\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial refrigeration equipment\u003c\/li\u003e\n\u003cli\u003eAir-conditioning systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003ePlease confirm the following before ordering:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete model\u003c\/li\u003e\n\u003cli\u003eODF connection size\u003c\/li\u003e\n\u003cli\u003eRequired coil voltage\u003c\/li\u003e\n\u003cli\u003eComplete valve or valve body only\u003c\/li\u003e\n\u003cli\u003eRefrigerant\u003c\/li\u003e\n\u003cli\u003ePipeline application\u003c\/li\u003e\n\u003cli\u003eOperating pressure and temperature\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HONGSEN","offers":[{"title":"HVD8-3T","offer_id":44034516975675,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"HVD10-4T","offer_id":44034517008443,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"HVD10-5T","offer_id":44034517041211,"sku":null,"price":21.0,"currency_code":"USD","in_stock":true},{"title":"HVD15-6T","offer_id":44034517073979,"sku":null,"price":30.0,"currency_code":"USD","in_stock":true},{"title":"HVD25-9T","offer_id":44034517106747,"sku":null,"price":67.0,"currency_code":"USD","in_stock":true},{"title":"HVD32-11T","offer_id":44034517139515,"sku":null,"price":93.0,"currency_code":"USD","in_stock":true},{"title":"HVD40-13T","offer_id":44034517172283,"sku":null,"price":117.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-25_135923_668.png?v=1787637712"},{"product_id":"hongsen-hvp-large-piston-solenoid-valves","title":"HONGSEN HVP Series Large Piston Solenoid Valves","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eHONGSEN HVP Series piston solenoid valves are designed for large refrigeration pipelines requiring reliable on-off control and high refrigerant flow capacity.\u003c\/p\u003e\n\u003cp\u003eThe series is suitable for one-way flow in liquid, suction-gas and hot-gas lines used in commercial refrigeration, industrial cold-storage systems and air-conditioning equipment. Available ODF connections range from 1-1\/8 inch to 2-1\/8 inch.\u003c\/p\u003e\n\u003cp\u003eThe valve body and solenoid coil may be supplied as a complete assembly or as separate components.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge-capacity piston-operated design\u003c\/li\u003e\n\u003cli\u003eNormally closed operation\u003c\/li\u003e\n\u003cli\u003eOne-way refrigerant flow\u003c\/li\u003e\n\u003cli\u003eODF solder connections\u003c\/li\u003e\n\u003cli\u003eSuitable for liquid, suction and hot-gas lines\u003c\/li\u003e\n\u003cli\u003eMaximum working pressure up to 45 bar\u003c\/li\u003e\n\u003cli\u003eValve and coil can be supplied separately\u003c\/li\u003e\n\u003cli\u003eStandard three-wire coil connector\u003c\/li\u003e\n\u003cli\u003eSuitable for commercial and industrial refrigeration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHONGSEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eHVP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve Type\u003c\/td\u003e\n\u003ctd\u003eLarge piston-operated solenoid valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Position\u003c\/td\u003e\n\u003ctd\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Direction\u003c\/td\u003e\n\u003ctd\u003eOne-way\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eODF solder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Refrigerants\u003c\/td\u003e\n\u003ctd\u003eSpecified HCFC and HFC refrigerants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium Temperature\u003c\/td\u003e\n\u003ctd\u003e−30°C to +105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Coil Voltage\u003c\/td\u003e\n\u003ctd\u003eAC 220V or AC 380V, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted Voltage Variation\u003c\/td\u003e\n\u003ctd\u003e+10% \/ −15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Connection\u003c\/td\u003e\n\u003ctd\u003eStandard three-wire plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid MOPD\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePublished Coil Power\u003c\/td\u003e\n\u003ctd\u003e24W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe specifications and model data below are taken from HONGSEN’s official HVP product information.\u003c\/p\u003e\n\u003ch3\u003e\n\u003ca href=\"https:\/\/www.zjhsjx.com\/en\/pd.jsp?id=41\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/a\u003eModel Selection\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eMinimum ΔP\u003c\/th\u003e\n\u003cth\u003eLiquid MOPD\u003c\/th\u003e\n\u003cth\u003eMaximum Working Pressure\u003c\/th\u003e\n\u003cth\u003eKv\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVP25\u003c\/td\u003e\n\u003ctd\u003e1-1\/8\" ODF\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003ctd\u003e10 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVP32\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\" ODF\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003ctd\u003e16 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVP40\u003c\/td\u003e\n\u003ctd\u003e1-5\/8\" ODF\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003ctd\u003e25 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVP54\u003c\/td\u003e\n\u003ctd\u003e2-1\/8\" ODF\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003ctd\u003e28 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAvailable Variants\u003c\/h3\u003e\n\u003cpre dir=\"ltr\"\u003e\u003ccode\u003eHVP25 — 1-1\/8 ODF — AC220V\nHVP32 — 1-3\/8 ODF — AC220V\nHVP40 — 1-5\/8 ODF — AC220V\nHVP54 — 2-1\/8 ODF — AC220V\u003c\/code\u003e\u003c\/pre\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge cold-storage systems\u003c\/li\u003e\n\u003cli\u003eIndustrial refrigeration plants\u003c\/li\u003e\n\u003cli\u003eLarge liquid refrigerant lines\u003c\/li\u003e\n\u003cli\u003eSuction-gas pipelines\u003c\/li\u003e\n\u003cli\u003eHot-gas defrost pipelines\u003c\/li\u003e\n\u003cli\u003eCentral refrigeration systems\u003c\/li\u003e\n\u003cli\u003eCommercial air-conditioning equipment\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HONGSEN","offers":[{"title":"HVP25","offer_id":44034523791419,"sku":null,"price":104.0,"currency_code":"USD","in_stock":true},{"title":"HVP32","offer_id":44034523824187,"sku":null,"price":110.0,"currency_code":"USD","in_stock":true},{"title":"HVP40","offer_id":44034523856955,"sku":null,"price":118.0,"currency_code":"USD","in_stock":true},{"title":"HVP54","offer_id":44034523889723,"sku":null,"price":127.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-25_135947_100.png?v=1787637749"},{"product_id":"hongsen-hvh-compact-piston-solenoid-valves","title":"HONGSEN HVH Series Compact Piston Solenoid Valves","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eHONGSEN HVH Series piston solenoid valves provide electrically operated refrigerant shut-off for smaller refrigeration pipelines.\u003c\/p\u003e\n\u003cp\u003eThe valves are designed for one-way flow and can be installed in liquid, suction-gas and hot-gas lines used in cold rooms, refrigeration equipment and air-conditioning systems.\u003c\/p\u003e\n\u003cp\u003eThe HVH3-2T and HVH8-3T models use compact ODF solder connections and are available with AC220V coils in the listed stock configuration.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact piston-operated construction\u003c\/li\u003e\n\u003cli\u003eNormally closed operation\u003c\/li\u003e\n\u003cli\u003eDesigned for one-way refrigerant flow\u003c\/li\u003e\n\u003cli\u003eODF solder connections\u003c\/li\u003e\n\u003cli\u003eSuitable for liquid, suction-gas and hot-gas lines\u003c\/li\u003e\n\u003cli\u003eValve body and coil can be supplied separately\u003c\/li\u003e\n\u003cli\u003eMaximum working pressure up to 45 bar\u003c\/li\u003e\n\u003cli\u003eStandard plug-type coil connection\u003c\/li\u003e\n\u003cli\u003eSuitable for commercial refrigeration and cold rooms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHONGSEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eHVH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve Type\u003c\/td\u003e\n\u003ctd\u003eCompact piston-operated solenoid valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Position\u003c\/td\u003e\n\u003ctd\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Direction\u003c\/td\u003e\n\u003ctd\u003eOne-way\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eODF solder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Refrigerants\u003c\/td\u003e\n\u003ctd\u003eSpecified HCFC and HFC refrigerants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium Temperature\u003c\/td\u003e\n\u003ctd\u003e−30°C to +140°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Coil Voltage\u003c\/td\u003e\n\u003ctd\u003eAC 220V or AC 380V, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom Coil Voltage\u003c\/td\u003e\n\u003ctd\u003eAvailable by request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted Voltage Variation\u003c\/td\u003e\n\u003ctd\u003e+10% \/ −15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Connection\u003c\/td\u003e\n\u003ctd\u003eStandard three-wire plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid MOPD\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe model values are based on HONGSEN’s official HVH product data.\u003c\/p\u003e\n\u003ch3\u003e\n\u003ca href=\"https:\/\/www.zjhsjx.com\/en\/sys-pd\/38.html\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/a\u003eModel Selection\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eMinimum ΔP\u003c\/th\u003e\n\u003cth\u003eLiquid MOPD\u003c\/th\u003e\n\u003cth\u003eMaximum Working Pressure\u003c\/th\u003e\n\u003cth\u003eKv\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVH3-2T\u003c\/td\u003e\n\u003ctd\u003e1\/4\" ODF\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003ctd\u003e0.27 m³\/h\u003c\/td\u003e\n\u003ctd\u003e0.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVH8-3T\u003c\/td\u003e\n\u003ctd\u003e3\/8\" ODF\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003ctd\u003e0.80 m³\/h\u003c\/td\u003e\n\u003ctd\u003e0.63 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAvailable Variants\u003c\/h3\u003e\n\u003cpre dir=\"ltr\"\u003e\u003ccode\u003eHVH3-2T — 1\/4 ODF — AC220V\nHVH8-3T — 3\/8 ODF — AC220V\u003c\/code\u003e\u003c\/pre\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSmall and medium cold rooms\u003c\/li\u003e\n\u003cli\u003eRefrigeration liquid lines\u003c\/li\u003e\n\u003cli\u003eCompressor suction lines\u003c\/li\u003e\n\u003cli\u003eHot-gas pipelines\u003c\/li\u003e\n\u003cli\u003eRefrigerated display equipment\u003c\/li\u003e\n\u003cli\u003eCondensing units\u003c\/li\u003e\n\u003cli\u003eCommercial air-conditioning systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HONGSEN","offers":[{"title":"HVH3-2T","offer_id":44034530312251,"sku":null,"price":17.0,"currency_code":"USD","in_stock":true},{"title":"HVH8-3T","offer_id":44034530345019,"sku":null,"price":21.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-25_135849_560.png?v=1787637813"},{"product_id":"hongsen-hv-series-refrigeration-solenoid-valves","title":"HONGSEN HV Series Refrigeration Solenoid Valves","description":"\u003ch2\u003ePRODUCT DESCRIPTION\u003c\/h2\u003e\n\u003cp\u003eThe HONGSEN HV Series consists of refrigeration solenoid valves designed for one-way flow control in liquid, suction-gas and hot-gas lines used in refrigeration, cold-storage and air-conditioning systems.\u003c\/p\u003e\n\u003cp\u003eThe series includes direct-operated and servo-operated designs. HV3 models are direct-operated and can open with zero pressure differential, while HV8 and larger models use a servo-operated structure and require the specified minimum pressure differential.\u003c\/p\u003e\n\u003cp\u003eSAE flare and ODF solder connection versions are available. Models ending in \u003cstrong\u003eT\u003c\/strong\u003e identify the ODF solder version. Valve assemblies can be supplied complete with a coil, while valve bodies and compatible coils may also be ordered separately.\u003c\/p\u003e\n\u003cp\u003eOur currently listed valve assemblies are supplied with an AC 220 V coil. Confirm the model, connection size, refrigerant, operating conditions and required coil voltage before ordering.\u003c\/p\u003e\n\u003ch2\u003eKEY FEATURES\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for refrigeration and air-conditioning systems\u003c\/li\u003e\n\u003cli\u003eSuitable for liquid, suction-gas and hot-gas lines\u003c\/li\u003e\n\u003cli\u003eOne-way on\/off flow control\u003c\/li\u003e\n\u003cli\u003eDirect-operated HV3 models\u003c\/li\u003e\n\u003cli\u003eServo-operated HV8, HV10, HV15, HV20, HV25 and HV32 models\u003c\/li\u003e\n\u003cli\u003eSAE flare and ODF solder connection options\u003c\/li\u003e\n\u003cli\u003eMaximum working pressure up to 45 bar\u003c\/li\u003e\n\u003cli\u003eLiquid-line MOPD up to 31 bar\u003c\/li\u003e\n\u003cli\u003eCompatible with HCFC and HFC refrigerants specified by the customer\u003c\/li\u003e\n\u003cli\u003eValve bodies and coils can be supplied separately\u003c\/li\u003e\n\u003cli\u003eDifferent coil voltages available\u003c\/li\u003e\n\u003cli\u003eStandard three-wire insert-type coil connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTECHNICAL SPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eHV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRefrigeration Solenoid Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Direction\u003c\/td\u003e\n\u003ctd\u003eOne-way\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Structure\u003c\/td\u003e\n\u003ctd\u003eDirect-operated or servo-operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Lines\u003c\/td\u003e\n\u003ctd\u003eLiquid, suction-gas and hot-gas lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Refrigerants\u003c\/td\u003e\n\u003ctd\u003eHCFC\/HFC refrigerants specified by the customer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium Temperature\u003c\/td\u003e\n\u003ctd\u003e−30°C to +105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid-Line MOPD\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Power\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Coil Connection\u003c\/td\u003e\n\u003ctd\u003eThree-wire insert connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage Tolerance\u003c\/td\u003e\n\u003ctd\u003e+10% \/ −10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eZhejiang Hongsen Machinery Co., Ltd.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHONGSEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eCONFIRMED MODEL SELECTION\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003cth\u003eMinimum ΔP\u003c\/th\u003e\n\u003cth\u003eKv\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV3-2\u003c\/td\u003e\n\u003ctd\u003e1\/4 in SAE flare\u003c\/td\u003e\n\u003ctd\u003eDirect-operated\u003c\/td\u003e\n\u003ctd\u003e0.00 bar\u003c\/td\u003e\n\u003ctd\u003e0.16 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV8M3\u003c\/td\u003e\n\u003ctd\u003e3\/8 in SAE flare\u003c\/td\u003e\n\u003ctd\u003eServo-operated\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e0.80 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV10M4\u003c\/td\u003e\n\u003ctd\u003e1\/2 in SAE flare\u003c\/td\u003e\n\u003ctd\u003eServo-operated\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e1.90 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV15M5\u003c\/td\u003e\n\u003ctd\u003e5\/8 in SAE flare\u003c\/td\u003e\n\u003ctd\u003eServo-operated\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e2.60 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV15M6\u003c\/td\u003e\n\u003ctd\u003e3\/4 in SAE flare\u003c\/td\u003e\n\u003ctd\u003eServo-operated\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e2.60 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV3-2T\u003c\/td\u003e\n\u003ctd\u003e1\/4 in ODF solder\u003c\/td\u003e\n\u003ctd\u003eDirect-operated\u003c\/td\u003e\n\u003ctd\u003e0.00 bar\u003c\/td\u003e\n\u003ctd\u003e0.16 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV8M3T\u003c\/td\u003e\n\u003ctd\u003e3\/8 in ODF solder\u003c\/td\u003e\n\u003ctd\u003eServo-operated\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e0.80 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV8M4T\u003c\/td\u003e\n\u003ctd\u003e1\/2 in ODF solder\u003c\/td\u003e\n\u003ctd\u003eServo-operated\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e0.80 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV10M4T\u003c\/td\u003e\n\u003ctd\u003e1\/2 in ODF solder\u003c\/td\u003e\n\u003ctd\u003eServo-operated\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e1.90 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV15M5T\u003c\/td\u003e\n\u003ctd\u003e5\/8 in ODF solder\u003c\/td\u003e\n\u003ctd\u003eServo-operated\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e2.60 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV15M6T\u003c\/td\u003e\n\u003ctd\u003e3\/4 in ODF solder\u003c\/td\u003e\n\u003ctd\u003eServo-operated\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e2.60 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV20M7T\u003c\/td\u003e\n\u003ctd\u003e7\/8 in ODF solder\u003c\/td\u003e\n\u003ctd\u003eServo-operated\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e5.00 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV25M9T\u003c\/td\u003e\n\u003ctd\u003e1-1\/8 in ODF solder\u003c\/td\u003e\n\u003ctd\u003eServo-operated\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e10.00 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV32M11T\u003c\/td\u003e\n\u003ctd\u003e1-3\/8 in ODF solder\u003c\/td\u003e\n\u003ctd\u003eServo-operated\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e16.00 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eKv definition:\u003c\/strong\u003e Water flow in m³\/h at a pressure differential of 100 kPa and water density of 1 t\/m³.\u003c\/p\u003e\n\u003ch2\u003eMODEL NOTES\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModels without the \u003cstrong\u003eT\u003c\/strong\u003e suffix use SAE flare connections.\u003c\/li\u003e\n\u003cli\u003eModels ending in \u003cstrong\u003eT\u003c\/strong\u003e use ODF solder connections.\u003c\/li\u003e\n\u003cli\u003eHV3 models are direct-operated.\u003c\/li\u003e\n\u003cli\u003eHV8 and larger models are servo-operated.\u003c\/li\u003e\n\u003cli\u003eThe two 1\/2-inch ODF models are not duplicates:\n\u003cul\u003e\n\u003cli\u003eHV8M4T: Kv 0.80 m³\/h\u003c\/li\u003e\n\u003cli\u003eHV10M4T: Kv 1.90 m³\/h\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eFinal valve sizing must be based on refrigerant, line function, capacity, temperature and pressure conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWalk-in coolers and freezer rooms\u003c\/li\u003e\n\u003cli\u003eCommercial refrigeration systems\u003c\/li\u003e\n\u003cli\u003eCold-storage equipment\u003c\/li\u003e\n\u003cli\u003eRefrigerated warehouses\u003c\/li\u003e\n\u003cli\u003eCondensing units\u003c\/li\u003e\n\u003cli\u003eLiquid refrigerant lines\u003c\/li\u003e\n\u003cli\u003eSuction-gas lines\u003c\/li\u003e\n\u003cli\u003eHot-gas lines\u003c\/li\u003e\n\u003cli\u003eAir-conditioning equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eORDERING INFORMATION\u003c\/h2\u003e\n\u003cp\u003ePlease provide:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRequired model or connection size\u003c\/li\u003e\n\u003cli\u003eSAE flare or ODF solder connection\u003c\/li\u003e\n\u003cli\u003eRefrigerant\u003c\/li\u003e\n\u003cli\u003eLiquid, suction-gas or hot-gas application\u003c\/li\u003e\n\u003cli\u003eRequired coil voltage and frequency\u003c\/li\u003e\n\u003cli\u003eOperating pressure and temperature\u003c\/li\u003e\n\u003cli\u003eRequired quantity\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HONGSEN","offers":[{"title":"HV3-2 – 1\/4 in SAE – AC220V","offer_id":44044333088827,"sku":null,"price":15.0,"currency_code":"USD","in_stock":true},{"title":"HV8M3 – 3\/8 in SAE – AC220V","offer_id":44044333121595,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"HV10M4 – 1\/2 in SAE – AC220V","offer_id":44044333154363,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"HV15M5 – 5\/8 in SAE – AC220V","offer_id":44044333187131,"sku":null,"price":27.0,"currency_code":"USD","in_stock":true},{"title":"HV15M6 – 3\/4 in SAE – AC220V","offer_id":44044333219899,"sku":null,"price":30.0,"currency_code":"USD","in_stock":true},{"title":"HV3-2T – 1\/4 in ODF – AC220V","offer_id":44044333252667,"sku":null,"price":15.0,"currency_code":"USD","in_stock":true},{"title":"HV8M3T – 3\/8 in ODF – AC220V","offer_id":44044333285435,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"HV8M4T – 1\/2 in ODF – AC220V","offer_id":44044333318203,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"HV10M4T – 1\/2 in ODF – AC220V","offer_id":44044333350971,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"HV15M5T – 5\/8 in ODF – AC220V","offer_id":44044333383739,"sku":null,"price":27.0,"currency_code":"USD","in_stock":true},{"title":"HV15M6T – 3\/4 in ODF – AC220V","offer_id":44044333416507,"sku":null,"price":30.0,"currency_code":"USD","in_stock":true},{"title":"HV20M7T – 7\/8 in ODF – AC220V","offer_id":44044333449275,"sku":null,"price":44.0,"currency_code":"USD","in_stock":true},{"title":"HV25M9T – 1-1\/8 in ODF – AC220V","offer_id":44044333482043,"sku":null,"price":53.0,"currency_code":"USD","in_stock":true},{"title":"HV32M11T – 1-3\/8 in ODF – AC220V","offer_id":44044333514811,"sku":null,"price":92.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-25_175601_927.png?v=1787734598"},{"product_id":"hongsen-model-10-refrigeration-solenoid-valves","title":"HONGSEN Model 10 Refrigeration Solenoid Valves","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe HONGSEN Model 10 Series includes direct-operated and servo-operated solenoid valves designed for one-way refrigerant flow.\u003c\/p\u003e\n\u003cp\u003eThese valves are suitable for liquid, suction and hot-gas lines in refrigeration systems, cold-storage equipment and air-conditioning units. Both SAE flare and ODF solder connection options are available to meet different piping requirements.\u003c\/p\u003e\n\u003cp\u003eModel 10 valves can be supplied as complete assemblies or as separate valve bodies and solenoid coils, making maintenance and replacement more convenient.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect-operated or servo-operated construction\u003c\/li\u003e\n\u003cli\u003eDesigned for one-way refrigerant flow\u003c\/li\u003e\n\u003cli\u003eSuitable for liquid, suction and hot-gas lines\u003c\/li\u003e\n\u003cli\u003eSAE flare and ODF solder connections available\u003c\/li\u003e\n\u003cli\u003eCompatible with specified HCFC and HFC refrigerants\u003c\/li\u003e\n\u003cli\u003eValve body and solenoid coil can be supplied separately\u003c\/li\u003e\n\u003cli\u003eMultiple coil voltages available\u003c\/li\u003e\n\u003cli\u003eStandard three-wire plug-in coil connection\u003c\/li\u003e\n\u003cli\u003eSuitable for refrigeration, cold-storage and air-conditioning systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAvailable Models\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eConnection Type\u003c\/th\u003e\n\u003cth\u003eKv\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1020-2\u003c\/td\u003e\n\u003ctd\u003e1\/4 in\u003c\/td\u003e\n\u003ctd\u003eSAE Flare\u003c\/td\u003e\n\u003ctd\u003e0.175 m³\/h\u003c\/td\u003e\n\u003ctd\u003e350 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1028-2\u003c\/td\u003e\n\u003ctd\u003e1\/4 in\u003c\/td\u003e\n\u003ctd\u003eODF Solder\u003c\/td\u003e\n\u003ctd\u003e0.175 m³\/h\u003c\/td\u003e\n\u003ctd\u003e315 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1064-3\u003c\/td\u003e\n\u003ctd\u003e3\/8 in\u003c\/td\u003e\n\u003ctd\u003eSAE Flare\u003c\/td\u003e\n\u003ctd\u003e0.800 m³\/h\u003c\/td\u003e\n\u003ctd\u003e450 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1068-3\u003c\/td\u003e\n\u003ctd\u003e3\/8 in\u003c\/td\u003e\n\u003ctd\u003eODF Solder\u003c\/td\u003e\n\u003ctd\u003e0.800 m³\/h\u003c\/td\u003e\n\u003ctd\u003e390 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1064-4\u003c\/td\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003ctd\u003eSAE Flare\u003c\/td\u003e\n\u003ctd\u003e0.800 m³\/h\u003c\/td\u003e\n\u003ctd\u003e480 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1068-4\u003c\/td\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003ctd\u003eODF Solder\u003c\/td\u003e\n\u003ctd\u003e0.800 m³\/h\u003c\/td\u003e\n\u003ctd\u003e390 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1070-5\u003c\/td\u003e\n\u003ctd\u003e5\/8 in\u003c\/td\u003e\n\u003ctd\u003eSAE Flare\u003c\/td\u003e\n\u003ctd\u003e2.610 m³\/h\u003c\/td\u003e\n\u003ctd\u003e800 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1078-5\u003c\/td\u003e\n\u003ctd\u003e5\/8 in\u003c\/td\u003e\n\u003ctd\u003eODF Solder\u003c\/td\u003e\n\u003ctd\u003e2.610 m³\/h\u003c\/td\u003e\n\u003ctd\u003e655 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1078-6\u003c\/td\u003e\n\u003ctd\u003e3\/4 in\u003c\/td\u003e\n\u003ctd\u003eODF Solder\u003c\/td\u003e\n\u003ctd\u003e4.300 m³\/h\u003c\/td\u003e\n\u003ctd\u003e660 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cblockquote\u003e\n\u003cp\u003eWeight values exclude the flare connection nut where applicable.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003eNominal Liquid Refrigeration Capacity\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Group\u003c\/th\u003e\n\u003cth\u003eR22\u003c\/th\u003e\n\u003cth\u003eHFC-134a\u003c\/th\u003e\n\u003cth\u003eR404A\/R502\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1020-2 \/ 1028-2\u003c\/td\u003e\n\u003ctd\u003e3.15 kW\u003c\/td\u003e\n\u003ctd\u003e2.95 kW\u003c\/td\u003e\n\u003ctd\u003e2.08 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1064-3 \/ 1068-3\u003c\/td\u003e\n\u003ctd\u003e14.50 kW\u003c\/td\u003e\n\u003ctd\u003e13.50 kW\u003c\/td\u003e\n\u003ctd\u003e9.50 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1064-4 \/ 1068-4\u003c\/td\u003e\n\u003ctd\u003e14.50 kW\u003c\/td\u003e\n\u003ctd\u003e13.50 kW\u003c\/td\u003e\n\u003ctd\u003e9.50 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1070-5 \/ 1078-5\u003c\/td\u003e\n\u003ctd\u003e47.00 kW\u003c\/td\u003e\n\u003ctd\u003e44.00 kW\u003c\/td\u003e\n\u003ctd\u003e31.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1078-6\u003c\/td\u003e\n\u003ctd\u003e77.50 kW\u003c\/td\u003e\n\u003ctd\u003e72.05 kW\u003c\/td\u003e\n\u003ctd\u003e51.10 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve Operation\u003c\/td\u003e\n\u003ctd\u003eDirect-operated or servo-operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Direction\u003c\/td\u003e\n\u003ctd\u003eOne way\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Refrigerants\u003c\/td\u003e\n\u003ctd\u003eHCFC or HFC, as specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium Temperature\u003c\/td\u003e\n\u003ctd\u003e−30°C to +105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e3.0 MPa \/ 30 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Opening Differential\u003c\/td\u003e\n\u003ctd\u003eDirect-operated: 0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Opening Differential\u003c\/td\u003e\n\u003ctd\u003eServo-operated: 0.02 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Pressure Differential\u003c\/td\u003e\n\u003ctd\u003e2.5 MPa \/ 25 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Coil Voltage\u003c\/td\u003e\n\u003ctd\u003eAC220V or AC380V, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage Tolerance\u003c\/td\u003e\n\u003ctd\u003e+10% \/ −15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Connection\u003c\/td\u003e\n\u003ctd\u003eStandard three-wire plug-in connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCold-room refrigeration systems\u003c\/li\u003e\n\u003cli\u003eCommercial refrigeration equipment\u003c\/li\u003e\n\u003cli\u003eRefrigerated storage equipment\u003c\/li\u003e\n\u003cli\u003eLiquid refrigerant lines\u003c\/li\u003e\n\u003cli\u003eCompressor suction lines\u003c\/li\u003e\n\u003cli\u003eHot-gas lines\u003c\/li\u003e\n\u003cli\u003eAir-conditioning systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to Select\u003c\/h2\u003e\n\u003cp\u003ePlease confirm the following information before ordering:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRequired model\u003c\/li\u003e\n\u003cli\u003ePipe connection size\u003c\/li\u003e\n\u003cli\u003eSAE flare or ODF solder connection\u003c\/li\u003e\n\u003cli\u003eRefrigerant\u003c\/li\u003e\n\u003cli\u003eCoil voltage and frequency\u003c\/li\u003e\n\u003cli\u003eInstallation line: liquid, suction or hot gas\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HONGSEN","offers":[{"title":"1020-2","offer_id":44048524181563,"sku":null,"price":11.0,"currency_code":"USD","in_stock":true},{"title":"1028-2","offer_id":44048524214331,"sku":null,"price":11.0,"currency_code":"USD","in_stock":true},{"title":"1064-3","offer_id":44048524247099,"sku":null,"price":14.0,"currency_code":"USD","in_stock":true},{"title":"1068-3","offer_id":44048524279867,"sku":null,"price":14.0,"currency_code":"USD","in_stock":true},{"title":"1064-4","offer_id":44048524312635,"sku":null,"price":14.0,"currency_code":"USD","in_stock":true},{"title":"1068-4","offer_id":44048524345403,"sku":null,"price":14.0,"currency_code":"USD","in_stock":true},{"title":"1070-5","offer_id":44048524378171,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"1078-5","offer_id":44048524410939,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"1078-6","offer_id":44048524443707,"sku":null,"price":20.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-27_095917_560.png?v=1787796029"},{"product_id":"hongsen-sv-series-refrigeration-solenoid-valves","title":"HONGSEN SV Series Refrigeration Solenoid Valves","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eHONGSEN SV Series solenoid valves are designed to control one-way refrigerant flow in refrigeration and air-conditioning systems.\u003c\/p\u003e\n\u003cp\u003eThe series includes direct-operated and servo-operated models for use in liquid, suction and hot-gas lines. SAE flare and ODF solder connections are available in sizes ranging from 1\/4 inch to 7\/8 inch.\u003c\/p\u003e\n\u003cp\u003eThe valve body and solenoid coil can be supplied as a complete assembly or separately for replacement and servicing.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect-operated and servo-operated models\u003c\/li\u003e\n\u003cli\u003eDesigned for one-way refrigerant flow\u003c\/li\u003e\n\u003cli\u003eSuitable for liquid, suction and hot-gas lines\u003c\/li\u003e\n\u003cli\u003eSAE flare and ODF solder connections\u003c\/li\u003e\n\u003cli\u003eConnection sizes from 1\/4 to 7\/8 inch\u003c\/li\u003e\n\u003cli\u003eCompatible with specified HCFC and HFC refrigerants\u003c\/li\u003e\n\u003cli\u003eReplaceable solenoid coil\u003c\/li\u003e\n\u003cli\u003eMultiple coil voltage options\u003c\/li\u003e\n\u003cli\u003eSuitable for cold rooms and commercial refrigeration systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAvailable Models\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eMinimum Opening Differential\u003c\/th\u003e\n\u003cth\u003eKv\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV20-2\u003c\/td\u003e\n\u003ctd\u003e1\/4 in\u003c\/td\u003e\n\u003ctd\u003eSAE Flare\u003c\/td\u003e\n\u003ctd\u003e0 bar\u003c\/td\u003e\n\u003ctd\u003e0.16 m³\/h\u003c\/td\u003e\n\u003ctd\u003e395 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV28-2\u003c\/td\u003e\n\u003ctd\u003e1\/4 in\u003c\/td\u003e\n\u003ctd\u003eODF Solder\u003c\/td\u003e\n\u003ctd\u003e0 bar\u003c\/td\u003e\n\u003ctd\u003e0.16 m³\/h\u003c\/td\u003e\n\u003ctd\u003e395 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV64-3\u003c\/td\u003e\n\u003ctd\u003e3\/8 in\u003c\/td\u003e\n\u003ctd\u003eSAE Flare\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e0.80 m³\/h\u003c\/td\u003e\n\u003ctd\u003e496 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV68-3\u003c\/td\u003e\n\u003ctd\u003e3\/8 in\u003c\/td\u003e\n\u003ctd\u003eODF Solder\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e0.80 m³\/h\u003c\/td\u003e\n\u003ctd\u003e496 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV64-4\u003c\/td\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003ctd\u003eSAE Flare\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e0.80 m³\/h\u003c\/td\u003e\n\u003ctd\u003e503 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV68-4\u003c\/td\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003ctd\u003eODF Solder\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e0.80 m³\/h\u003c\/td\u003e\n\u003ctd\u003e458 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV70-5\u003c\/td\u003e\n\u003ctd\u003e5\/8 in\u003c\/td\u003e\n\u003ctd\u003eSAE Flare\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e2.20 m³\/h\u003c\/td\u003e\n\u003ctd\u003e746 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV78-5\u003c\/td\u003e\n\u003ctd\u003e5\/8 in\u003c\/td\u003e\n\u003ctd\u003eODF Solder\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e2.20 m³\/h\u003c\/td\u003e\n\u003ctd\u003e598 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV70-6\u003c\/td\u003e\n\u003ctd\u003e3\/4 in\u003c\/td\u003e\n\u003ctd\u003eSAE Flare\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e2.20 m³\/h\u003c\/td\u003e\n\u003ctd\u003e816 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV78-6\u003c\/td\u003e\n\u003ctd\u003e3\/4 in\u003c\/td\u003e\n\u003ctd\u003eODF Solder\u003c\/td\u003e\n\u003ctd\u003e0.05 bar\u003c\/td\u003e\n\u003ctd\u003e2.20 m³\/h\u003c\/td\u003e\n\u003ctd\u003e616 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV98-7\u003c\/td\u003e\n\u003ctd\u003e7\/8 in\u003c\/td\u003e\n\u003ctd\u003eODF Solder\u003c\/td\u003e\n\u003ctd\u003e0.20 bar\u003c\/td\u003e\n\u003ctd\u003e2.60 m³\/h\u003c\/td\u003e\n\u003ctd\u003e1,020 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eNominal Refrigeration Capacity\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eValve Group\u003c\/th\u003e\n\u003cth\u003eR22\/R407C Liquid\u003c\/th\u003e\n\u003cth\u003eR134a Liquid\u003c\/th\u003e\n\u003cth\u003eR404A\/R507 Liquid\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV20 \/ SV28\u003c\/td\u003e\n\u003ctd\u003e5.10 kW\u003c\/td\u003e\n\u003ctd\u003e5.00 kW\u003c\/td\u003e\n\u003ctd\u003e3.80 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV64 \/ SV68\u003c\/td\u003e\n\u003ctd\u003e16.10 kW\u003c\/td\u003e\n\u003ctd\u003e14.80 kW\u003c\/td\u003e\n\u003ctd\u003e11.20 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV70 \/ SV78\u003c\/td\u003e\n\u003ctd\u003e38.20 kW\u003c\/td\u003e\n\u003ctd\u003e35.30 kW\u003c\/td\u003e\n\u003ctd\u003e26.70 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV98\u003c\/td\u003e\n\u003ctd\u003e52.30 kW\u003c\/td\u003e\n\u003ctd\u003e48.30 kW\u003c\/td\u003e\n\u003ctd\u003e36.50 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Direction\u003c\/td\u003e\n\u003ctd\u003eOne way\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Refrigerants\u003c\/td\u003e\n\u003ctd\u003eHCFC, HFC and related approved media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium Temperature\u003c\/td\u003e\n\u003ctd\u003e−30°C to +105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e45 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid MOPD\u003c\/td\u003e\n\u003ctd\u003e31 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard AC Coil Voltages\u003c\/td\u003e\n\u003ctd\u003eAC24V, AC110V, AC220V and AC380V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard AC Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard DC Coil Voltage\u003c\/td\u003e\n\u003ctd\u003eDC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Tolerance\u003c\/td\u003e\n\u003ctd\u003e±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Connection\u003c\/td\u003e\n\u003ctd\u003eStandard three-wire plug-in connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigeration liquid lines\u003c\/li\u003e\n\u003cli\u003eCompressor suction lines\u003c\/li\u003e\n\u003cli\u003eHot-gas lines\u003c\/li\u003e\n\u003cli\u003eCold-room refrigeration systems\u003c\/li\u003e\n\u003cli\u003eRefrigerated storage equipment\u003c\/li\u003e\n\u003cli\u003eCommercial refrigeration systems\u003c\/li\u003e\n\u003cli\u003eAir-conditioning equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to Select\u003c\/h2\u003e\n\u003cp\u003ePlease provide:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eValve model\u003c\/li\u003e\n\u003cli\u003ePipe size\u003c\/li\u003e\n\u003cli\u003eSAE flare or ODF solder connection\u003c\/li\u003e\n\u003cli\u003eRefrigerant\u003c\/li\u003e\n\u003cli\u003eCoil voltage and frequency\u003c\/li\u003e\n\u003cli\u003eApplication line\u003c\/li\u003e\n\u003cli\u003eRequired refrigeration capacity\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HONGSEN","offers":[{"title":"SV20-2","offer_id":44048525623355,"sku":null,"price":14.0,"currency_code":"USD","in_stock":true},{"title":"SV28-2","offer_id":44048525656123,"sku":null,"price":14.0,"currency_code":"USD","in_stock":true},{"title":"SV64-3","offer_id":44048525688891,"sku":null,"price":15.0,"currency_code":"USD","in_stock":true},{"title":"SV68-3","offer_id":44048525721659,"sku":null,"price":15.0,"currency_code":"USD","in_stock":true},{"title":"SV64-4","offer_id":44048525754427,"sku":null,"price":16.0,"currency_code":"USD","in_stock":true},{"title":"SV68-4","offer_id":44048525787195,"sku":null,"price":16.0,"currency_code":"USD","in_stock":true},{"title":"SV70-5","offer_id":44048525819963,"sku":null,"price":20.0,"currency_code":"USD","in_stock":true},{"title":"SV78-5","offer_id":44048525852731,"sku":null,"price":20.0,"currency_code":"USD","in_stock":true},{"title":"SV70-6","offer_id":44048525885499,"sku":null,"price":22.0,"currency_code":"USD","in_stock":true},{"title":"SV78-6","offer_id":44048525918267,"sku":null,"price":22.0,"currency_code":"USD","in_stock":true},{"title":"SV98-7","offer_id":44048525951035,"sku":null,"price":32.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-27_095029_173.png?v=1787796111"}],"url":"https:\/\/xiaxuecoldroom.com\/collections\/refrigeration-solenoid-valves.oembed","provider":"XIAXUE Refrigeration","version":"1.0","type":"link"}