{"title":"Thermostatic Expansion Valves","description":null,"products":[{"product_id":"stf-nrf-hw100-r22-thermostatic-expansion-valve","title":"STF NRF HW100 R22 Internally Equalized Thermostatic Expansion Valve","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe STF NRF HW100 Series thermostatic expansion valves regulate liquid refrigerant flow into the evaporator while maintaining stable superheat under changing refrigeration loads.\u003c\/p\u003e\n\u003cp\u003eThese internally equalized R22 valves are suitable for refrigeration, freezing, air-conditioning, commercial refrigeration and transport refrigeration systems. They feature adjustable static superheat, SAE external-thread connections and a replaceable inlet strainer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for R22 refrigeration systems\u003c\/li\u003e\n\u003cli\u003eInternally equalized configuration\u003c\/li\u003e\n\u003cli\u003eStable and adjustable superheat control\u003c\/li\u003e\n\u003cli\u003eFactory static superheat setting: 3.5 K\u003c\/li\u003e\n\u003cli\u003eStatic superheat adjustment range: 2–8 K\u003c\/li\u003e\n\u003cli\u003eEvaporating temperature range: -40°C to +10°C\u003c\/li\u003e\n\u003cli\u003eSafe working pressure: 3.0 MPa\u003c\/li\u003e\n\u003cli\u003eMaximum sensing-bulb temperature: 75°C\u003c\/li\u003e\n\u003cli\u003eCapillary tube length: 1 m\u003c\/li\u003e\n\u003cli\u003eSAE external-thread connections\u003c\/li\u003e\n\u003cli\u003eReplaceable inlet strainer\u003c\/li\u003e\n\u003cli\u003eMOP configurations available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSTF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eShanghai Thermostat Factory Co., Ltd.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eNRF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eThermostatic Expansion Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEqualization\u003c\/td\u003e\n\u003ctd\u003eInternal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostatic Charge\u003c\/td\u003e\n\u003ctd\u003eHW100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe Working Pressure\u003c\/td\u003e\n\u003ctd\u003e3.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Bulb Temperature\u003c\/td\u003e\n\u003ctd\u003e75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapillary Tube Length\u003c\/td\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eSAE External Thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Static Superheat\u003c\/td\u003e\n\u003ctd\u003e3.5 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic Superheat Adjustment Range\u003c\/td\u003e\n\u003ctd\u003e2–8 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Strainer\u003c\/td\u003e\n\u003ctd\u003eReplaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eModel and Nominal Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eNominal Capacity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNRF1-1\/2HW100\u003c\/td\u003e\n\u003ctd\u003e1.5 TR \/ 5.28 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNRF2HW100\u003c\/td\u003e\n\u003ctd\u003e2 TR \/ 7.04 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNRF3HW100\u003c\/td\u003e\n\u003ctd\u003e3 TR \/ 10.56 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNRF4HW100\u003c\/td\u003e\n\u003ctd\u003e4 TR \/ 14.08 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNRF5HW100\u003c\/td\u003e\n\u003ctd\u003e5 TR \/ 17.60 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNRF6HW100\u003c\/td\u003e\n\u003ctd\u003e6 TR \/ 21.12 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNRF7-1\/2HW100\u003c\/td\u003e\n\u003ctd\u003e7.5 TR \/ 26.40 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNRF12HW100\u003c\/td\u003e\n\u003ctd\u003e12 TR \/ 42.24 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSelection Notice\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease verify the refrigerant, cooling capacity, evaporating temperature, condensing temperature, liquid subcooling, pressure drop, MOP requirement and connection size before ordering.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"STF","offers":[{"title":"NRF1-1\/2HW100","offer_id":43911056228411,"sku":null,"price":23.0,"currency_code":"USD","in_stock":true},{"title":"NRF2HW100","offer_id":43911056261179,"sku":null,"price":23.0,"currency_code":"USD","in_stock":true},{"title":"NRF3HW100","offer_id":43911056293947,"sku":null,"price":23.0,"currency_code":"USD","in_stock":true},{"title":"NRF4HW100","offer_id":43911056326715,"sku":null,"price":23.0,"currency_code":"USD","in_stock":true},{"title":"NRF5HW100","offer_id":43911056359483,"sku":null,"price":27.0,"currency_code":"USD","in_stock":true},{"title":"NRF6HW100","offer_id":43911056392251,"sku":null,"price":27.0,"currency_code":"USD","in_stock":true},{"title":"NRF7-1\/2HW100","offer_id":43911056425019,"sku":null,"price":28.0,"currency_code":"USD","in_stock":true},{"title":"NRF12HW100","offer_id":43911056457787,"sku":null,"price":33.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-10_131804_504.png?v=1786342083"},{"product_id":"stf-rtbmt-series-thermostatic-expansion-valve","title":"STF RTBMT-HC Bi-Flow Thermostatic Expansion Valves for R22","description":"\u003ch3\u003e\u003cspan\u003ePRODUCT DESCRIPTION\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSTF RTBMT-HC thermostatic expansion valves are designed for refrigerant metering and superheat control in reversible R22 heat-pump and air-conditioning systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe bi-flow construction allows refrigerant flow in both directions, reducing the need for separate expansion valves and external check-valve bypass arrangements in compatible reversible circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe valve modulates refrigerant flow according to evaporator load and maintains controlled outlet superheat. Model selection must be based on refrigerant, evaporating temperature, condensing temperature, pressure drop, required capacity and connection configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKEY FEATURES\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e• Bi-flow thermostatic expansion-valve construction\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Designed for compatible reversible heat-pump circuits\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Superheat control in both operating directions\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Factory static-superheat setting of approximately 3.5 K\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Static-superheat adjustment range from 2 to 8 K\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Evaporating-temperature range from −40°C to +10°C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• ODF solder connections\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• External pressure equalization on applicable RTBMT configurations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• MOP configurations available by order\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Brass valve body with copper connections\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eGENERAL TECHNICAL DATA\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBi-flow thermostatic expansion valve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTBMT-HC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRefrigerant Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eR22 – confirm on nameplate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEvaporating-Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−40°C to +10°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFactory Static Superheat\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 3.5 K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStatic-Superheat Adjustment Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2–8 K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eODF solder\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEqualization\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExternal on applicable RTBMT models\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlow Direction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBi-flow\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMOP Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable by order\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShanghai Thermostat Factory Co., Ltd.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShangheng \/ STF Controls\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eMODEL OPTIONS\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Capacity Class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRTBMT14HC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14 TR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e49.3 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRTBMT18HC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 TR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63.4 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRTBMT22HC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 TR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e77.4 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRTBMT26HC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26 TR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e91.5 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCAPACITY NOTICE\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe values above identify nominal capacity classes. Actual valve capacity changes with refrigerant condition, evaporating temperature, condensing temperature, subcooling and pressure drop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDo not select the valve using refrigeration tonnage alone.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe exact refrigerant charge, MOP setting, inlet size, outlet size and external equalizer connection must be verified from the product nameplate or manufacturer’s order code before shipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAPPLICATIONS\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e• Reversible heat-pump systems\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Commercial air-conditioning equipment\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Reversible refrigeration circuits\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Packaged air-conditioning units\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Compatible liquid chillers\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Heating and cooling systems requiring bi-directional refrigerant flow\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eINSTALLATION NOTES\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e• Match the valve to the refrigerant and calculated system capacity.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Confirm the direction and piping arrangement before brazing.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Protect the valve body and power element from excessive brazing heat.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Mount the sensing bulb according to standard refrigeration practices.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Connect the external equalizer to the correct suction-line location.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Adjust superheat only after the system has reached stable operating conditions.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Installation must be performed by a qualified refrigeration technician.\u003c\/span\u003e\u003c\/p\u003e","brand":"STF","offers":[{"title":"RTBMT14HC","offer_id":43921763369019,"sku":null,"price":46.0,"currency_code":"USD","in_stock":true},{"title":"RTBMT18HC","offer_id":43921763401787,"sku":null,"price":48.0,"currency_code":"USD","in_stock":true},{"title":"RTBMT22HC","offer_id":43921763434555,"sku":null,"price":50.0,"currency_code":"USD","in_stock":true},{"title":"RTBMT26HC","offer_id":43921763467323,"sku":null,"price":52.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-11_154159_293.png?v=1786434234"},{"product_id":"hongsen-erf22-erf22w-r22-thermostatic-expansion-valves","title":"HONGSEN ERF22 and ERF22W R22 Thermostatic Expansion Valves","description":"\u003ch1\u003eProduct Description\u003c\/h1\u003e\n\u003cp\u003eThe HONGSEN ERF22 and ERF22W Series thermostatic expansion valves are designed to regulate the flow of R22 refrigerant into direct-expansion evaporators according to the evaporator outlet superheat.\u003c\/p\u003e\n\u003cp\u003eTwo connection and pressure-equalization configurations are available:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eERF22:\u003c\/strong\u003e internally equalized valve with metric flare connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eERF22W:\u003c\/strong\u003e externally equalized valve with inch SAE flare connections and a 1\/4 SAE external equalizer port\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMultiple orifice sizes are available to cover nominal refrigeration capacities from 3.5 to 52.7 kW under the manufacturer’s stated rating conditions. Selecting the correct model requires confirmation of the refrigerant, cooling capacity, evaporating temperature, condensing temperature, pressure drop and required connection sizes.\u003c\/p\u003e\n\u003cp\u003eThe complete valve model and connection configuration should be confirmed before ordering.\u003c\/p\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for R22 refrigeration systems\u003c\/li\u003e\n\u003cli\u003eAutomatic refrigerant-flow regulation according to superheat\u003c\/li\u003e\n\u003cli\u003eInternal and external equalization options\u003c\/li\u003e\n\u003cli\u003eMetric flare and inch SAE flare configurations\u003c\/li\u003e\n\u003cli\u003eMultiple orifice sizes from Ø1.0 to Ø9.0\u003c\/li\u003e\n\u003cli\u003eNominal capacities from 3.5 to 52.7 kW\u003c\/li\u003e\n\u003cli\u003eIntegrated inlet filtering component\u003c\/li\u003e\n\u003cli\u003eAdjustable valve mechanism\u003c\/li\u003e\n\u003cli\u003eSuitable for commercial refrigeration and cold-storage systems\u003c\/li\u003e\n\u003cli\u003eMultiple connection sizes for different system capacities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHONGSEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eERF Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eThermostatic Expansion Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERF22 Configuration\u003c\/td\u003e\n\u003ctd\u003eInternal equalization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERF22 Connection Type\u003c\/td\u003e\n\u003ctd\u003eMetric flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERF22W Configuration\u003c\/td\u003e\n\u003ctd\u003eExternal equalization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERF22W Connection Type\u003c\/td\u003e\n\u003ctd\u003eInch SAE flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Equalizer\u003c\/td\u003e\n\u003ctd\u003e1\/4 SAE on ERF22W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Orifice Sizes\u003c\/td\u003e\n\u003ctd\u003eØ1.0–Ø9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity Range\u003c\/td\u003e\n\u003ctd\u003e3.5–52.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity Range\u003c\/td\u003e\n\u003ctd\u003e1.0–15.0 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Rating Evaporating Temperature\u003c\/td\u003e\n\u003ctd\u003e+5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Rating Condensing Temperature\u003c\/td\u003e\n\u003ctd\u003e+40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Rating Subcooling\u003c\/td\u003e\n\u003ctd\u003e2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Application\u003c\/td\u003e\n\u003ctd\u003eRefrigerant flow control for direct-expansion evaporators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eAvailable Models\u003c\/h1\u003e\n\u003ch2\u003eERF22 Metric-Flare Models\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable style=\"width: 100%; height: 215.532px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 14.8502%; height: 19.5938px;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"width: 36.6682%; height: 19.5938px;\"\u003eStock Connection Reference\u003c\/th\u003e\n\u003cth style=\"width: 22.7159%; height: 19.5938px;\"\u003eNominal Capacity\u003c\/th\u003e\n\u003cth style=\"width: 21.1222%; height: 19.5938px;\"\u003eInventory SKU\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 14.8502%; height: 19.5938px;\"\u003eERF22-Ø1.0\u003c\/td\u003e\n\u003ctd style=\"width: 36.6682%; height: 19.5938px;\"\u003eDg8 × Dg10, metric\u003c\/td\u003e\n\u003ctd style=\"width: 22.7159%; height: 19.5938px;\"\u003e1.0 TR \/ 3.5 kW\u003c\/td\u003e\n\u003ctd style=\"width: 21.1222%; height: 19.5938px;\"\u003e5250-000A-Ø1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 14.8502%; height: 19.5938px;\"\u003eERF22-Ø1.5\u003c\/td\u003e\n\u003ctd style=\"width: 36.6682%; height: 19.5938px;\"\u003eDg8 × Dg10, metric\u003c\/td\u003e\n\u003ctd style=\"width: 22.7159%; height: 19.5938px;\"\u003e1.6 TR \/ 5.6 kW\u003c\/td\u003e\n\u003ctd style=\"width: 21.1222%; height: 19.5938px;\"\u003e5250-000A-Ø1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 14.8502%; height: 19.5938px;\"\u003eERF22-Ø2.0\u003c\/td\u003e\n\u003ctd style=\"width: 36.6682%; height: 19.5938px;\"\u003eDg8 × Dg10, metric\u003c\/td\u003e\n\u003ctd style=\"width: 22.7159%; height: 19.5938px;\"\u003e2.0 TR \/ 7.0 kW\u003c\/td\u003e\n\u003ctd style=\"width: 21.1222%; height: 19.5938px;\"\u003e5250-000A-Ø2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 14.8502%; height: 19.5938px;\"\u003eERF22-Ø3.0\u003c\/td\u003e\n\u003ctd style=\"width: 36.6682%; height: 19.5938px;\"\u003eDg8 × Dg10, metric\u003c\/td\u003e\n\u003ctd style=\"width: 22.7159%; height: 19.5938px;\"\u003e3.0 TR \/ 10.5 kW\u003c\/td\u003e\n\u003ctd style=\"width: 21.1222%; height: 19.5938px;\"\u003e5250-000B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 14.8502%; height: 19.5938px;\"\u003eERF22-Ø4.0\u003c\/td\u003e\n\u003ctd style=\"width: 36.6682%; height: 19.5938px;\"\u003eDg8 × Dg10, metric\u003c\/td\u003e\n\u003ctd style=\"width: 22.7159%; height: 19.5938px;\"\u003e5.0 TR \/ 17.6 kW\u003c\/td\u003e\n\u003ctd style=\"width: 21.1222%; height: 19.5938px;\"\u003e5250-000C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 14.8502%; height: 19.5938px;\"\u003eERF22-Ø5.0\u003c\/td\u003e\n\u003ctd style=\"width: 36.6682%; height: 19.5938px;\"\u003eDg8 × Dg13, metric\u003c\/td\u003e\n\u003ctd style=\"width: 22.7159%; height: 19.5938px;\"\u003e6.0 TR \/ 21.0 kW\u003c\/td\u003e\n\u003ctd style=\"width: 21.1222%; height: 19.5938px;\"\u003e5252-000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 14.8502%; height: 19.5938px;\"\u003eERF22-Ø6.0\u003c\/td\u003e\n\u003ctd style=\"width: 36.6682%; height: 19.5938px;\"\u003eDg8 × Dg13, metric\u003c\/td\u003e\n\u003ctd style=\"width: 22.7159%; height: 19.5938px;\"\u003e7.5 TR \/ 26.0 kW\u003c\/td\u003e\n\u003ctd style=\"width: 21.1222%; height: 19.5938px;\"\u003e5252-000B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 14.8502%; height: 19.5938px;\"\u003eERF22-Ø7.0\u003c\/td\u003e\n\u003ctd style=\"width: 36.6682%; height: 19.5938px;\"\u003eDg10 × Dg13, metric\u003c\/td\u003e\n\u003ctd style=\"width: 22.7159%; height: 19.5938px;\"\u003e8.5 TR \/ 29.9 kW\u003c\/td\u003e\n\u003ctd style=\"width: 21.1222%; height: 19.5938px;\"\u003eERF22-7-00G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 14.8502%; height: 19.5938px;\"\u003eERF22-Ø8.0\u003c\/td\u003e\n\u003ctd style=\"width: 36.6682%; height: 19.5938px;\"\u003eDg10 × Dg13, metric\u003c\/td\u003e\n\u003ctd style=\"width: 22.7159%; height: 19.5938px;\"\u003e12.0 TR \/ 42.2 kW\u003c\/td\u003e\n\u003ctd style=\"width: 21.1222%; height: 19.5938px;\"\u003eERF22-8-00G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 14.8502%; height: 19.5938px;\"\u003eERF22-Ø9.0\u003c\/td\u003e\n\u003ctd style=\"width: 36.6682%; height: 19.5938px;\"\u003eDg10 × Dg13, metric\u003c\/td\u003e\n\u003ctd style=\"width: 22.7159%; height: 19.5938px;\"\u003e15.0 TR \/ 52.7 kW\u003c\/td\u003e\n\u003ctd style=\"width: 21.1222%; height: 19.5938px;\"\u003eERF22-9-00G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eERF22W Inch-Flare Models\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eInlet × Outlet\u003c\/th\u003e\n\u003cth\u003eExternal Equalizer\u003c\/th\u003e\n\u003cth\u003eNominal Capacity\u003c\/th\u003e\n\u003cth\u003eInventory SKU\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eERF22W-Ø3.0\u003c\/td\u003e\n\u003ctd\u003e3\/8 × 1\/2 SAE\u003c\/td\u003e\n\u003ctd\u003e1\/4 SAE\u003c\/td\u003e\n\u003ctd\u003e3.0 TR \/ 10.5 kW\u003c\/td\u003e\n\u003ctd\u003e5261-000B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERF22W-Ø4.0\u003c\/td\u003e\n\u003ctd\u003e3\/8 × 1\/2 SAE\u003c\/td\u003e\n\u003ctd\u003e1\/4 SAE\u003c\/td\u003e\n\u003ctd\u003e5.0 TR \/ 17.6 kW\u003c\/td\u003e\n\u003ctd\u003e5261-000C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERF22W-Ø5.0\u003c\/td\u003e\n\u003ctd\u003e1\/2 × 5\/8 SAE\u003c\/td\u003e\n\u003ctd\u003e1\/4 SAE\u003c\/td\u003e\n\u003ctd\u003e6.0 TR \/ 21.0 kW\u003c\/td\u003e\n\u003ctd\u003e5263-000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERF22W-Ø6.0\u003c\/td\u003e\n\u003ctd\u003e1\/2 × 5\/8 SAE\u003c\/td\u003e\n\u003ctd\u003e1\/4 SAE\u003c\/td\u003e\n\u003ctd\u003e7.5 TR \/ 26.5 kW\u003c\/td\u003e\n\u003ctd\u003e5263-000B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERF22W-Ø7.0\u003c\/td\u003e\n\u003ctd\u003e1\/2 × 5\/8 SAE\u003c\/td\u003e\n\u003ctd\u003e1\/4 SAE\u003c\/td\u003e\n\u003ctd\u003e8.5 TR \/ 29.9 kW\u003c\/td\u003e\n\u003ctd\u003eERF22W-7-00Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERF22W-Ø9.0\u003c\/td\u003e\n\u003ctd\u003e1\/2 × 5\/8 SAE\u003c\/td\u003e\n\u003ctd\u003e1\/4 SAE\u003c\/td\u003e\n\u003ctd\u003e15.0 TR \/ 52.7 kW\u003c\/td\u003e\n\u003ctd\u003eERF22W-9-00Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eModel Selection Guidance\u003c\/h1\u003e\n\u003cp\u003eSelect the required valve according to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant type\u003c\/li\u003e\n\u003cli\u003eRequired nominal cooling capacity\u003c\/li\u003e\n\u003cli\u003eEvaporating and condensing temperatures\u003c\/li\u003e\n\u003cli\u003eLiquid-line pressure drop\u003c\/li\u003e\n\u003cli\u003eInternal or external equalization requirement\u003c\/li\u003e\n\u003cli\u003eInlet and outlet connection sizes\u003c\/li\u003e\n\u003cli\u003eEvaporator pressure drop\u003c\/li\u003e\n\u003cli\u003eRequired orifice size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eExternal equalization is recommended where the evaporator or distributor creates a significant pressure drop. Final selection should be completed by a qualified refrigeration technician.\u003c\/p\u003e\n\u003ch1\u003eApplications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eWalk-in cooler and freezer systems\u003c\/li\u003e\n\u003cli\u003eCommercial refrigeration equipment\u003c\/li\u003e\n\u003cli\u003eCold-storage condensing units\u003c\/li\u003e\n\u003cli\u003eDisplay cabinets\u003c\/li\u003e\n\u003cli\u003eRefrigerated warehouses\u003c\/li\u003e\n\u003cli\u003eFood-processing refrigeration systems\u003c\/li\u003e\n\u003cli\u003eDirect-expansion evaporators\u003c\/li\u003e\n\u003cli\u003eOther compatible R22 refrigeration systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eInstallation Notes\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the refrigerant and valve capacity before installation.\u003c\/li\u003e\n\u003cli\u003eCheck the flow-direction arrow on the valve body.\u003c\/li\u003e\n\u003cli\u003eInstall the sensing bulb securely on a clean horizontal suction line.\u003c\/li\u003e\n\u003cli\u003ePosition the bulb according to accepted refrigeration practice.\u003c\/li\u003e\n\u003cli\u003eConnect the external equalizer downstream of the sensing-bulb position.\u003c\/li\u003e\n\u003cli\u003ePrevent excessive installation heat from reaching the power element.\u003c\/li\u003e\n\u003cli\u003eLeak-test the system after installation.\u003c\/li\u003e\n\u003cli\u003eInstallation and adjustment must be performed by a qualified refrigeration technician.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HONGSEN","offers":[{"title":"ERF22 \/ ERF22-Ø1.0","offer_id":44023565254715,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"ERF22 \/ ERF22-Ø1.5","offer_id":44023565287483,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"ERF22 \/ ERF22-Ø2.0","offer_id":44023565320251,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"ERF22 \/ ERF22-Ø3.0","offer_id":44023565353019,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"ERF22 \/ ERF22-Ø4.0","offer_id":44023565385787,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"ERF22 \/ ERF22-Ø5.0","offer_id":44023565418555,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"ERF22 \/ ERF22-Ø6.0","offer_id":44023565451323,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"ERF22 \/ ERF22-Ø7.0","offer_id":44023565484091,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"ERF22 \/ ERF22-Ø8.0","offer_id":44023565516859,"sku":null,"price":22.0,"currency_code":"USD","in_stock":true},{"title":"ERF22 \/ ERF22-Ø9.0","offer_id":44023565549627,"sku":null,"price":23.0,"currency_code":"USD","in_stock":true},{"title":"ERF22W \/ ERF22W-Ø3.0","offer_id":44023565910075,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"ERF22W \/ ERF22W-Ø4.0","offer_id":44023565942843,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"ERF22W \/ ERF22W-Ø5.0","offer_id":44023565975611,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"ERF22W \/ ERF22W-Ø6.0","offer_id":44023566008379,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"ERF22W \/ ERF22W-Ø7.0","offer_id":44023566041147,"sku":null,"price":22.0,"currency_code":"USD","in_stock":true},{"title":"ERF22W \/ ERF22W-Ø9.0","offer_id":44023566073915,"sku":null,"price":26.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-21_112806_633.png?v=1787283374"},{"product_id":"hongsen-frf22w-r22-odf-thermostatic-expansion-valves","title":"HONGSEN FRF22W R22 External Equalized ODF Thermostatic Expansion Valves","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003ch4\u003eProduct Overview\u003c\/h4\u003e\n\u003cp\u003eThe HONGSEN FRF22W Series consists of externally equalized thermostatic expansion valves designed to regulate the flow of liquid R22 refrigerant entering an evaporator while maintaining stable superheat at the evaporator outlet.\u003c\/p\u003e\n\u003cp\u003eThe external equalizer connection allows the valve to compensate for pressure drop across the evaporator and suction line, making this series suitable for medium- and large-capacity evaporators. ODF solder connections provide a permanent, compact connection for commercial and industrial refrigeration piping.\u003c\/p\u003e\n\u003cp\u003eAvailable models cover nominal capacities from 3 to 38 TR, with multiple inlet and outlet connection combinations for cold rooms, refrigeration equipment, ice-making systems, dehumidifiers and commercial refrigeration installations.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for R22 refrigeration systems\u003c\/li\u003e\n\u003cli\u003eExternal pressure equalization\u003c\/li\u003e\n\u003cli\u003e1\/4-inch external equalizer connection\u003c\/li\u003e\n\u003cli\u003eODF solder inlet and outlet connections\u003c\/li\u003e\n\u003cli\u003eNominal capacities from 3 to 38 TR\u003c\/li\u003e\n\u003cli\u003eNominal refrigeration capacities from 10 to 134 kW\u003c\/li\u003e\n\u003cli\u003eAdjustable superheat range of 2°C to 8°C\u003c\/li\u003e\n\u003cli\u003eSuitable for medium temperatures from -40°C to +10°C\u003c\/li\u003e\n\u003cli\u003eMultiple inlet and outlet connection combinations\u003c\/li\u003e\n\u003cli\u003eSuitable for commercial and industrial refrigeration systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHONGSEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eFRF22W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eThermostatic Expansion Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEqualization\u003c\/td\u003e\n\u003ctd\u003eExternal Equalization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eODF Solder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Equalizer Connection\u003c\/td\u003e\n\u003ctd\u003e1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Medium Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable Superheat Range\u003c\/td\u003e\n\u003ctd\u003e2°C to 8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e2.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Test Pressure\u003c\/td\u003e\n\u003ctd\u003e3.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacity Range\u003c\/td\u003e\n\u003ctd\u003e3–38 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Refrigeration Capacity\u003c\/td\u003e\n\u003ctd\u003e10–134 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eZhejiang Hongsen Machinery Co., Ltd.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eManufacturer nominal capacities are stated at an evaporating temperature of +5°C, condensing temperature of +40°C and superheat of 2°C.\u003c\/p\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/www.zjhsjx.com\/en\/sys-pd\/36.html\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/a\u003eAvailable Models\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003eInlet\u003c\/th\u003e\n\u003cth\u003eOutlet\u003c\/th\u003e\n\u003cth\u003eNominal TR\u003c\/th\u003e\n\u003cth\u003eCapacity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-3-3-5\u003c\/td\u003e\n\u003ctd\u003e01.32.200\u003c\/td\u003e\n\u003ctd\u003e3\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e5\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e10 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-3-4-5\u003c\/td\u003e\n\u003ctd\u003e01.32.199\u003c\/td\u003e\n\u003ctd\u003e1\/2 in ODF\u003c\/td\u003e\n\u003ctd\u003e5\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e10 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-4-4-7\u003c\/td\u003e\n\u003ctd\u003e01.32.201\u003c\/td\u003e\n\u003ctd\u003e1\/2 in ODF\u003c\/td\u003e\n\u003ctd\u003e7\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e14 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-6-4-5\u003c\/td\u003e\n\u003ctd\u003e01.32.202\u003c\/td\u003e\n\u003ctd\u003e1\/2 in ODF\u003c\/td\u003e\n\u003ctd\u003e5\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e20 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-6-4-7\u003c\/td\u003e\n\u003ctd\u003e01.32.203\u003c\/td\u003e\n\u003ctd\u003e1\/2 in ODF\u003c\/td\u003e\n\u003ctd\u003e7\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e20 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-7.5-5-7\u003c\/td\u003e\n\u003ctd\u003e01.32.204\u003c\/td\u003e\n\u003ctd\u003e5\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e7\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003ctd\u003e27 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-11-5-7\u003c\/td\u003e\n\u003ctd\u003e01.32.205\u003c\/td\u003e\n\u003ctd\u003e5\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e7\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e38 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-11-5-9\u003c\/td\u003e\n\u003ctd\u003e01.32.206\u003c\/td\u003e\n\u003ctd\u003e5\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e1-1\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e38 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-12-5-7\u003c\/td\u003e\n\u003ctd\u003e01.32.207\u003c\/td\u003e\n\u003ctd\u003e5\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e7\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e43 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-12-5-9\u003c\/td\u003e\n\u003ctd\u003e01.32.208\u003c\/td\u003e\n\u003ctd\u003e5\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e1-1\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e43 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-15-5-9\u003c\/td\u003e\n\u003ctd\u003e01.32.209\u003c\/td\u003e\n\u003ctd\u003e5\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e1-1\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e54 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-15-7-9\u003c\/td\u003e\n\u003ctd\u003e01.32.210\u003c\/td\u003e\n\u003ctd\u003e7\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e1-1\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e54 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-18-7-9\u003c\/td\u003e\n\u003ctd\u003e01.32.211\u003c\/td\u003e\n\u003ctd\u003e7\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e1-1\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e63 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-18-7-11\u003c\/td\u003e\n\u003ctd\u003e01.32.212\u003c\/td\u003e\n\u003ctd\u003e7\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e1-3\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e63 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-26-7-11\u003c\/td\u003e\n\u003ctd\u003e01.32.213\u003c\/td\u003e\n\u003ctd\u003e7\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e1-3\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e92 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-26-9-11\u003c\/td\u003e\n\u003ctd\u003e01.32.214\u003c\/td\u003e\n\u003ctd\u003e1-1\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e1-3\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e92 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-30-7-11\u003c\/td\u003e\n\u003ctd\u003e01.32.215\u003c\/td\u003e\n\u003ctd\u003e7\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e1-3\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e104 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-30-9-11\u003c\/td\u003e\n\u003ctd\u003e01.32.216\u003c\/td\u003e\n\u003ctd\u003e1-1\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e1-3\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e104 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRF22W-38-9-11\u003c\/td\u003e\n\u003ctd\u003e01.32.217\u003c\/td\u003e\n\u003ctd\u003e1-1\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e1-3\/8 in ODF\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003e134 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eInstallation Notice\u003c\/h4\u003e\n\u003cp\u003eProtect the valve body with a wet cloth during brazing and direct the torch flame away from the valve body. Use an appropriate low-temperature silver brazing alloy. Installation, adjustment and maintenance should be performed by qualified refrigeration technicians.\u003c\/p\u003e\n\u003ch4\u003eApplications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial cold rooms\u003c\/li\u003e\n\u003cli\u003eWalk-in coolers and freezers\u003c\/li\u003e\n\u003cli\u003eRefrigerated warehouses\u003c\/li\u003e\n\u003cli\u003eIce-making equipment\u003c\/li\u003e\n\u003cli\u003eDehumidification equipment\u003c\/li\u003e\n\u003cli\u003eCommercial refrigeration systems\u003c\/li\u003e\n\u003cli\u003eMedium- and large-capacity evaporators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSelection Information\u003c\/h4\u003e\n\u003cp\u003ePlease provide the following information before ordering:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant\u003c\/li\u003e\n\u003cli\u003eRequired refrigeration capacity\u003c\/li\u003e\n\u003cli\u003eEvaporating temperature\u003c\/li\u003e\n\u003cli\u003eCondensing temperature\u003c\/li\u003e\n\u003cli\u003eInlet and outlet connection sizes\u003c\/li\u003e\n\u003cli\u003eEvaporator pressure drop\u003c\/li\u003e\n\u003cli\u003eRequired model and quantity\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HONGSEN","offers":[{"title":"FRF22W-3-3-5","offer_id":44023906959419,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-3-4-5","offer_id":44023906992187,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-4-4-7","offer_id":44023907024955,"sku":null,"price":18.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-6-4-5","offer_id":44023907057723,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-6-4-7","offer_id":44023907090491,"sku":null,"price":19.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-7.5-5-7","offer_id":44023907123259,"sku":null,"price":20.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-11-5-7","offer_id":44023907156027,"sku":null,"price":22.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-11-5-9","offer_id":44023907188795,"sku":null,"price":22.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-12-5-7","offer_id":44023907221563,"sku":null,"price":23.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-12-5-9","offer_id":44023907254331,"sku":null,"price":23.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-15-5-9","offer_id":44023907287099,"sku":null,"price":26.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-15-7-9","offer_id":44023907319867,"sku":null,"price":26.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-18-7-9","offer_id":44023907352635,"sku":null,"price":35.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-18-7-11","offer_id":44023907385403,"sku":null,"price":35.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-26-7-11","offer_id":44023907418171,"sku":null,"price":43.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-26-9-11","offer_id":44023907450939,"sku":null,"price":43.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-30-7-11","offer_id":44023907483707,"sku":null,"price":52.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-30-9-11","offer_id":44023907516475,"sku":null,"price":52.0,"currency_code":"USD","in_stock":true},{"title":"FRF22W-38-9-11","offer_id":44023907549243,"sku":null,"price":64.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-21_134756_658.png?v=1787291721"},{"product_id":"hongsen-rf22-r22-extended-flare-expansion-valves","title":"HONGSEN RF22 R22 Internal Equalized Extended Flare Thermostatic Expansion Valves","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003ch4\u003eProduct Overview\u003c\/h4\u003e\n\u003cp\u003eThe HONGSEN RF22 Series consists of internally equalized thermostatic expansion valves designed for R22 refrigeration systems. These extended-type models use SAE flare inlet and outlet connections, providing a serviceable threaded installation for cold rooms and commercial refrigeration equipment.\u003c\/p\u003e\n\u003cp\u003eThe valve regulates liquid refrigerant flow entering the evaporator according to the superheat detected by the sensing bulb. This helps maintain stable evaporator operation and reduces the risk of excessive liquid refrigerant returning to the compressor.\u003c\/p\u003e\n\u003cp\u003eThe available models cover multiple orifice sizes from Ø1.0 to Ø5.0. Model selection must be based on refrigeration capacity, operating temperatures, refrigerant pressure drop and connection size—not on orifice size alone.\u003c\/p\u003e\n\u003cp\u003eHONGSEN states that its thermostatic expansion valves are intended for evaporator refrigerant-flow control in cold storage, ice-making, dehumidification, refrigeration and air-conditioning applications. \u003ca href=\"https:\/\/www.zjhsjx.com\/en\/sys-pd\/35.html\"\u003e\u003cspan\u003eHONGSEN official expansion-valve information\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for R22 refrigeration systems\u003c\/li\u003e\n\u003cli\u003eInternal pressure equalization\u003c\/li\u003e\n\u003cli\u003eExtended-type valve construction\u003c\/li\u003e\n\u003cli\u003eSAE flare inlet and outlet connections\u003c\/li\u003e\n\u003cli\u003eMultiple orifice sizes from Ø1.0 to Ø5.0\u003c\/li\u003e\n\u003cli\u003eServiceable threaded installation\u003c\/li\u003e\n\u003cli\u003eSuitable for small- and medium-capacity refrigeration systems\u003c\/li\u003e\n\u003cli\u003eSuperheat-controlled refrigerant flow\u003c\/li\u003e\n\u003cli\u003eSuitable for cold rooms and commercial refrigeration equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHONGSEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eRF22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eThermostatic Expansion Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEqualization\u003c\/td\u003e\n\u003ctd\u003eInternal Equalization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eSAE Flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eExtended Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Orifice Sizes\u003c\/td\u003e\n\u003ctd\u003eØ1.0, Ø1.5, Ø2.0, Ø2.5, Ø3.0, Ø4.0, Ø5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eZhejiang Hongsen Machinery Co., Ltd.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eAvailable Models\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003eInlet × Outlet\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF22-Ø1.0\u003c\/td\u003e\n\u003ctd\u003e01.32.378\u003c\/td\u003e\n\u003ctd\u003e3\/8 × 1\/2 in SAE\u003c\/td\u003e\n\u003ctd\u003eExtended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF22-Ø1.5\u003c\/td\u003e\n\u003ctd\u003e01.32.379\u003c\/td\u003e\n\u003ctd\u003e3\/8 × 1\/2 in SAE\u003c\/td\u003e\n\u003ctd\u003eExtended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF22-Ø2.0\u003c\/td\u003e\n\u003ctd\u003e01.32.380\u003c\/td\u003e\n\u003ctd\u003e3\/8 × 1\/2 in SAE\u003c\/td\u003e\n\u003ctd\u003eExtended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF22-Ø2.5\u003c\/td\u003e\n\u003ctd\u003e01.32.381\u003c\/td\u003e\n\u003ctd\u003e3\/8 × 1\/2 in SAE\u003c\/td\u003e\n\u003ctd\u003eExtended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF22-Ø3.0\u003c\/td\u003e\n\u003ctd\u003e01.32.382\u003c\/td\u003e\n\u003ctd\u003e3\/8 × 1\/2 in SAE\u003c\/td\u003e\n\u003ctd\u003eExtended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF22-Ø4.0\u003c\/td\u003e\n\u003ctd\u003e01.32.383\u003c\/td\u003e\n\u003ctd\u003e3\/8 × 1\/2 in SAE\u003c\/td\u003e\n\u003ctd\u003eExtended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF22-Ø5.0\u003c\/td\u003e\n\u003ctd\u003e01.32.384\u003c\/td\u003e\n\u003ctd\u003e3\/8 × 5\/8 in SAE\u003c\/td\u003e\n\u003ctd\u003eExtended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eApplications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCold room refrigeration systems\u003c\/li\u003e\n\u003cli\u003eCommercial display refrigeration\u003c\/li\u003e\n\u003cli\u003eRefrigerated cabinets\u003c\/li\u003e\n\u003cli\u003eIce-making equipment\u003c\/li\u003e\n\u003cli\u003eDehumidification equipment\u003c\/li\u003e\n\u003cli\u003eSmall- and medium-capacity evaporators\u003c\/li\u003e\n\u003cli\u003eRefrigeration maintenance and replacement projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eModel Selection Notice\u003c\/h4\u003e\n\u003cp\u003eBefore ordering, confirm:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant is R22\u003c\/li\u003e\n\u003cli\u003eRequired refrigeration capacity\u003c\/li\u003e\n\u003cli\u003eEvaporating and condensing temperatures\u003c\/li\u003e\n\u003cli\u003eInlet and outlet flare sizes\u003c\/li\u003e\n\u003cli\u003eAvailable installation space\u003c\/li\u003e\n\u003cli\u003eRequired orifice size\u003c\/li\u003e\n\u003cli\u003eExisting valve model or nameplate information\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HONGSEN","offers":[{"title":"RF22-Ø1.0","offer_id":44023913709627,"sku":null,"price":12.0,"currency_code":"USD","in_stock":true},{"title":"RF22-Ø1.5","offer_id":44023913742395,"sku":null,"price":12.0,"currency_code":"USD","in_stock":true},{"title":"RF22-Ø2.0","offer_id":44023913775163,"sku":null,"price":12.0,"currency_code":"USD","in_stock":true},{"title":"RF22-Ø2.5","offer_id":44023913807931,"sku":null,"price":12.0,"currency_code":"USD","in_stock":true},{"title":"RF22-Ø3.0","offer_id":44023913840699,"sku":null,"price":12.0,"currency_code":"USD","in_stock":true},{"title":"RF22-Ø4.0","offer_id":44023913873467,"sku":null,"price":12.0,"currency_code":"USD","in_stock":true},{"title":"RF22-Ø5.0","offer_id":44023913906235,"sku":null,"price":12.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-21_141141_659.png?v=1787292721"},{"product_id":"danfoss-tgex-r22-range-k-with-mop","title":"Danfoss TGEX \/ TGE Thermostatic Expansion Valves for R22 – Range K, With MOP","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDanfoss TGEX \/ TGE thermostatic expansion valves regulate liquid refrigerant flow into evaporators using a sensing bulb and capillary tube. This R22 selection features a fixed orifice, external pressure equalization, balanced-port construction and adjustable superheat.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Range K selection covers evaporating temperatures from −25°C to +10°C and includes a Maximum Operating Pressure charge. Twenty-one Danfoss codes are available, with manufacturer nominal R22 capacities from 10 to 134 kW and listed ratings from 3 to 38 TR.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRange K and MOP Function\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe K charge has a MOP point of +15°C saturation temperature. For R22, Danfoss lists the corresponding MOP point as 100 psig \/ 6.9 bar.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMOP is a control characteristic of the thermostatic charge. Maximum working pressure, or MWP, is the separate pressure rating of the valve. Select the charge according to the system’s operating requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCapacity and Connection Selection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNominal R22 capacities are based on an evaporating temperature of 4.4°C, condensing temperature of 38°C, liquid temperature ahead of the valve of 37°C and opening superheat of 4 K. Actual capacity requires selection at the operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAll selected codes use inch-size ODF solder connections and a 1\/4-inch ODF external equalization connection. Different codes can have the same nominal capacity but different inlet or outlet sizes, so the complete Danfoss code should be specified when ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eConstruction and Sensing Assembly\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe valves feature a brass body, copper connections and a stainless-steel power element, sensing bulb and capillary tube. TGE 10 and TGE 20 selections have 1.5 m capillary tubes; TGE 40 selections have 3 m capillary tubes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe standard static superheat setting is 4 K, with a published adjustment range of 0–8 K. The balanced-port design helps reduce the influence of changing pressure drop. Bi-flow performance should be checked for the intended operating direction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePacking and Ordering\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSupplier-listed carton quantities are 12 valves for TGE 10, 8 valves for TGE 20 and 6 valves for TGE 40. These quantities describe packing rather than minimum order requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSend XIAXUE Refrigeration the required Danfoss code, quantity, refrigerant, cooling duty, operating temperatures and copper tube sizes. Include the existing valve identification for replacement enquiries.\u003c\/span\u003e\u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"TGEX3 - 067N2000 - 3\/8 x 5\/8 in ODF","offer_id":44777730211899,"sku":null,"price":51.0,"currency_code":"USD","in_stock":true},{"title":"TGEX3 - 067N2001 - 1\/2 x 5\/8 in ODF","offer_id":44777730244667,"sku":null,"price":51.0,"currency_code":"USD","in_stock":true},{"title":"TGEX4 - 067N2002 - 1\/2 x 7\/8 in ODF","offer_id":44777730277435,"sku":null,"price":51.0,"currency_code":"USD","in_stock":true},{"title":"TGEX6 - 067N2003 - 1\/2 x 5\/8 in ODF","offer_id":44777730310203,"sku":null,"price":57.0,"currency_code":"USD","in_stock":true},{"title":"TGEX6 - 067N2004 - 1\/2 x 7\/8 in ODF","offer_id":44777730342971,"sku":null,"price":60.0,"currency_code":"USD","in_stock":true},{"title":"TGEX6 - 067N2005 - 5\/8 x 7\/8 in ODF","offer_id":44777730375739,"sku":null,"price":60.0,"currency_code":"USD","in_stock":true},{"title":"TGEX7.5 - 067N2006 - 5\/8 x 7\/8 in ODF","offer_id":44777730408507,"sku":null,"price":57.0,"currency_code":"USD","in_stock":true},{"title":"TGEX9 - 067N2415 - 5\/8 x 7\/8 in ODF","offer_id":44777730441275,"sku":null,"price":62.0,"currency_code":"USD","in_stock":true},{"title":"TGEX11 - 067N2007 - 5\/8 x 7\/8 in ODF","offer_id":44777730474043,"sku":null,"price":60.0,"currency_code":"USD","in_stock":true},{"title":"TGEX11 - 067N2008 - 5\/8 x 1 1\/8 in ODF","offer_id":44777730506811,"sku":null,"price":62.0,"currency_code":"USD","in_stock":true},{"title":"TGEX12 - 067N2009 - 5\/8 x 7\/8 in ODF","offer_id":44777730539579,"sku":null,"price":71.0,"currency_code":"USD","in_stock":true},{"title":"TGEX12 - 067N2010 - 5\/8 x 1 1\/8 in ODF","offer_id":44777730572347,"sku":null,"price":75.0,"currency_code":"USD","in_stock":true},{"title":"TGEX15 - 067N2011 - 5\/8 x 1 1\/8 in ODF","offer_id":44777730605115,"sku":null,"price":71.0,"currency_code":"USD","in_stock":true},{"title":"TGEX15 - 067N2012 - 7\/8 x 1 1\/8 in ODF","offer_id":44777730637883,"sku":null,"price":73.0,"currency_code":"USD","in_stock":true},{"title":"TGEX18 - 067N2013 - 7\/8 x 1 1\/8 in ODF","offer_id":44777730670651,"sku":null,"price":73.0,"currency_code":"USD","in_stock":true},{"title":"TGEX18 - 067N2014 - 7\/8 x 1 3\/8 in ODF","offer_id":44777730703419,"sku":null,"price":75.0,"currency_code":"USD","in_stock":true},{"title":"TGEX26 - 067N2015 - 7\/8 x 1 3\/8 in ODF","offer_id":44777730736187,"sku":null,"price":111.0,"currency_code":"USD","in_stock":true},{"title":"TGEX26 - 067N2016 - 1 1\/8 x 1 3\/8 in ODF","offer_id":44777730768955,"sku":null,"price":111.0,"currency_code":"USD","in_stock":true},{"title":"TGEX30 - 067N2017 - 7\/8 x 1 3\/8 in ODF","offer_id":44777730801723,"sku":null,"price":111.0,"currency_code":"USD","in_stock":true},{"title":"TGEX30 - 067N2018 - 1 1\/8 x 1 3\/8 in ODF","offer_id":44777730834491,"sku":null,"price":111.0,"currency_code":"USD","in_stock":true},{"title":"TGEX38 - 067N2019 - 1 1\/8 x 1 3\/8 in ODF","offer_id":44777730867259,"sku":null,"price":111.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/ChatGPTImageAug10_2026_10_14_11AM.png?v=1793070488"},{"product_id":"danfoss-tgex-r22-range-n-without-mop","title":"Danfoss TGEX \/ TGE Thermostatic Expansion Valves for R22 – Range N, Without MOP","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDanfoss TGEX \/ TGE thermostatic expansion valves use a sensing bulb and capillary tube to regulate liquid refrigerant flow to the evaporator. This R22 range combines a fixed orifice with external pressure equalization, balanced-port construction and adjustable superheat.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Range N selection covers evaporating temperatures from −40°C to +10°C and is supplied without MOP. Twenty-one Danfoss codes are included, covering manufacturer nominal R22 capacities from 10 to 134 kW, with listed ratings from 3 to 38 TR.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOperating Range and Application\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe −40°C figure is the lower limit of the published evaporating-temperature range. It is not a fixed operating point or a cold-room temperature setpoint.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eChoose the valve according to the refrigerant, evaporator load, evaporating temperature, condensing conditions and pressure losses. Applications requiring a MOP charge should be checked against the appropriate charge and code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCapacity and Model Identification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe nominal capacities are rated at an evaporating temperature of 4.4°C, condensing temperature of 38°C, liquid temperature ahead of the valve of 37°C and opening superheat of 4 K.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTGEX3, for example, corresponds to the listed 10 kW \/ 3 TR selection. The model suffix should not be interpreted as a kW value. TGE 10, TGE 20 and TGE 40 identify the manufacturer body families.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eConnections and Control Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe selected codes use inch-size ODF solder inlet and outlet connections, with a 1\/4-inch ODF external equalization connection. Inlet and outlet sizes must be checked against the exact code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTGE 10 and TGE 20 selections have 1.5 m capillary tubes, while TGE 40 selections have 3 m capillary tubes. Construction includes a brass body, copper connections and a stainless-steel power element, sensing bulb and capillary tube.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePublished family data specifies a standard static superheat setting of 4 K, adjustable from 0 to 8 K, and an opening superheat of 4 K. Bi-flow duty should be selected using the manufacturer’s performance data for the intended direction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePacking and Ordering\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSupplier-listed carton quantities are 12 valves for TGE 10, 8 for TGE 20 and 6 for TGE 40.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor a quotation from XIAXUE Refrigeration, provide the complete Danfoss code, quantity, refrigerant, cooling duty, operating temperatures and tube sizes. For replacement enquiries, include the existing valve code and nameplate information.\u003c\/span\u003e\u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"TGEX3 - 067N2150 - 3\/8 x 5\/8 in ODF","offer_id":44778650828859,"sku":null,"price":51.0,"currency_code":"USD","in_stock":true},{"title":"TGEX3 - 067N2151 - 1\/2 x 5\/8 in ODF","offer_id":44778650861627,"sku":null,"price":51.0,"currency_code":"USD","in_stock":true},{"title":"TGEX4 - 067N2152 - 1\/2 x 7\/8 in ODF","offer_id":44778650894395,"sku":null,"price":49.0,"currency_code":"USD","in_stock":true},{"title":"TGEX6 - 067N2153 - 1\/2 x 5\/8 in ODF","offer_id":44778650927163,"sku":null,"price":56.0,"currency_code":"USD","in_stock":true},{"title":"TGEX6 - 067N2154 - 1\/2 x 7\/8 in ODF","offer_id":44778650959931,"sku":null,"price":59.0,"currency_code":"USD","in_stock":true},{"title":"TGEX6 - 067N2155 - 5\/8 x 7\/8 in ODF","offer_id":44778650992699,"sku":null,"price":57.0,"currency_code":"USD","in_stock":true},{"title":"TGEX7.5 - 067N2156 - 5\/8 x 7\/8 in ODF","offer_id":44778651025467,"sku":null,"price":56.0,"currency_code":"USD","in_stock":true},{"title":"TGEX9 - 067N2460 - 5\/8 x 7\/8 in ODF","offer_id":44778651058235,"sku":null,"price":62.0,"currency_code":"USD","in_stock":true},{"title":"TGEX11 - 067N2157 - 5\/8 x 7\/8 in ODF","offer_id":44778651091003,"sku":null,"price":60.0,"currency_code":"USD","in_stock":true},{"title":"TGEX11 - 067N2158 - 5\/8 x 1 1\/8 in ODF","offer_id":44778651123771,"sku":null,"price":60.0,"currency_code":"USD","in_stock":true},{"title":"TGEX12 - 067N2159 - 5\/8 x 7\/8 in ODF","offer_id":44778651156539,"sku":null,"price":71.0,"currency_code":"USD","in_stock":true},{"title":"TGEX12 - 067N2160 - 5\/8 x 1 1\/8 in ODF","offer_id":44778651189307,"sku":null,"price":71.0,"currency_code":"USD","in_stock":true},{"title":"TGEX15 - 067N2161 - 5\/8 x 1 1\/8 in ODF","offer_id":44778651222075,"sku":null,"price":71.0,"currency_code":"USD","in_stock":true},{"title":"TGEX15 - 067N2162 - 7\/8 x 1 1\/8 in ODF","offer_id":44778651254843,"sku":null,"price":71.0,"currency_code":"USD","in_stock":true},{"title":"TGEX18 - 067N2163 - 7\/8 x 1 1\/8 in ODF","offer_id":44778651287611,"sku":null,"price":71.0,"currency_code":"USD","in_stock":true},{"title":"TGEX18 - 067N2164 - 7\/8 x 1 3\/8 in ODF","offer_id":44778651320379,"sku":null,"price":75.0,"currency_code":"USD","in_stock":true},{"title":"TGEX26 - 067N2165 - 7\/8 x 1 3\/8 in ODF","offer_id":44778651353147,"sku":null,"price":107.0,"currency_code":"USD","in_stock":true},{"title":"TGEX26 - 067N2166 - 1 1\/8 x 1 3\/8 in ODF","offer_id":44778651385915,"sku":null,"price":110.0,"currency_code":"USD","in_stock":true},{"title":"TGEX30 - 067N2167 - 7\/8 x 1 3\/8 in ODF","offer_id":44778651418683,"sku":null,"price":111.0,"currency_code":"USD","in_stock":true},{"title":"TGEX30 - 067N2168 - 1 1\/8 x 1 3\/8 in ODF","offer_id":44778651451451,"sku":null,"price":110.0,"currency_code":"USD","in_stock":true},{"title":"TGEX38 - 067N2169 - 1 1\/8 x 1 3\/8 in ODF","offer_id":44778651484219,"sku":null,"price":110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/ChatGPTImageAug10_2026_10_14_11AM.png?v=1793070488"}],"url":"https:\/\/xiaxuecoldroom.com\/collections\/thermostatic-expansion-valves.oembed","provider":"XIAXUE Refrigeration","version":"1.0","type":"link"}