{"title":"Valve Parts \u0026 Accessories","description":null,"products":[{"product_id":"danfoss-t2-te2-orifice-assemblies","title":"Danfoss T2 and TE2 Replaceable Orifice Assemblies - No. 01 to No. 06","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003ch3\u003eDanfoss T2 and TE2 Orifice Assemblies\u003c\/h3\u003e\n\u003cp\u003eDanfoss replaceable orifice assemblies are designed for T2 and TE2 thermostatic expansion valves used in air-conditioning and commercial refrigeration systems.\u003c\/p\u003e\n\u003cp\u003eSix orifice sizes are available. Each size provides a different refrigerant capacity, allowing the T2 or TE2 valve to be matched to the refrigerant, evaporator capacity and operating conditions of the system.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for Danfoss T2 and TE2 thermostatic expansion valves\u003c\/li\u003e\n\u003cli\u003eReplaceable orifice assembly\u003c\/li\u003e\n\u003cli\u003eAvailable in sizes No. 01 through No. 06\u003c\/li\u003e\n\u003cli\u003eOfficial product type: ORF\u003c\/li\u003e\n\u003cli\u003eSAE flare design\u003c\/li\u003e\n\u003cli\u003eSuitable for multiple refrigerants\u003c\/li\u003e\n\u003cli\u003eTemperature range: -40°C to +10°C\u003c\/li\u003e\n\u003cli\u003eNet weight: approximately 0.013 kg per piece\u003c\/li\u003e\n\u003cli\u003eEasy identification by orifice number and Danfoss code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Refrigerants\u003c\/h3\u003e\n\u003cp\u003eAccording to the official Danfoss specifications, these orifice assemblies are listed for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eR1234yf\u003c\/li\u003e\n\u003cli\u003eR134a\/R513A\u003c\/li\u003e\n\u003cli\u003eR22\/R407C\u003c\/li\u003e\n\u003cli\u003eR23\u003c\/li\u003e\n\u003cli\u003eR236fa\u003c\/li\u003e\n\u003cli\u003eR404A\/R507A\u003c\/li\u003e\n\u003cli\u003eR407A\u003c\/li\u003e\n\u003cli\u003eR407C\u003c\/li\u003e\n\u003cli\u003eR448A\u003c\/li\u003e\n\u003cli\u003eR449A\u003c\/li\u003e\n\u003cli\u003eR452A\u003c\/li\u003e\n\u003cli\u003eR454C\u003c\/li\u003e\n\u003cli\u003eR455A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant Selection Information\u003c\/h3\u003e\n\u003cp\u003eThis listing is for the \u003cstrong\u003eorifice assembly only\u003c\/strong\u003e. The thermostatic element and valve body are not included.\u003c\/p\u003e\n\u003cp\u003eCooling capacity varies according to the refrigerant and operating conditions. Always select the orifice by confirming:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDanfoss code number\u003c\/li\u003e\n\u003cli\u003eOrifice number\u003c\/li\u003e\n\u003cli\u003eRefrigerant\u003c\/li\u003e\n\u003cli\u003eRequired refrigeration capacity\u003c\/li\u003e\n\u003cli\u003eEvaporating temperature\u003c\/li\u003e\n\u003cli\u003eCondensing temperature\u003c\/li\u003e\n\u003cli\u003eLiquid refrigerant temperature\u003c\/li\u003e\n\u003cli\u003ePressure drop across the valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe thermostatic element must also be suitable for the refrigerant used in the system.\u003c\/p\u003e\n\u003ch2\u003eRated Capacity Table\u003c\/h2\u003e\n\u003cp\u003eThe following values are Danfoss Range N rated capacities.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOrifice\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eR134a\u003c\/th\u003e\n\u003cth\u003eR22\u003c\/th\u003e\n\u003cth\u003eR404A\u003c\/th\u003e\n\u003cth\u003eR407C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 01\u003c\/td\u003e\n\u003ctd\u003e068-2010\u003c\/td\u003e\n\u003ctd\u003e2.10 kW \/ 0.59 TR\u003c\/td\u003e\n\u003ctd\u003e3.50 kW \/ 1.00 TR\u003c\/td\u003e\n\u003ctd\u003e2.60 kW \/ 0.75 TR\u003c\/td\u003e\n\u003ctd\u003e3.50 kW \/ 1.00 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 02\u003c\/td\u003e\n\u003ctd\u003e068-2015\u003c\/td\u003e\n\u003ctd\u003e2.60 kW \/ 0.73 TR\u003c\/td\u003e\n\u003ctd\u003e4.70 kW \/ 1.30 TR\u003c\/td\u003e\n\u003ctd\u003e3.70 kW \/ 1.00 TR\u003c\/td\u003e\n\u003ctd\u003e4.80 kW \/ 1.40 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 03\u003c\/td\u003e\n\u003ctd\u003e068-2006\u003c\/td\u003e\n\u003ctd\u003e4.30 kW \/ 1.20 TR\u003c\/td\u003e\n\u003ctd\u003e8.00 kW \/ 2.30 TR\u003c\/td\u003e\n\u003ctd\u003e6.30 kW \/ 1.80 TR\u003c\/td\u003e\n\u003ctd\u003e8.10 kW \/ 2.30 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 04\u003c\/td\u003e\n\u003ctd\u003e068-2007\u003c\/td\u003e\n\u003ctd\u003e6.40 kW \/ 1.80 TR\u003c\/td\u003e\n\u003ctd\u003e12.10 kW \/ 3.40 TR\u003c\/td\u003e\n\u003ctd\u003e9.90 kW \/ 2.80 TR\u003c\/td\u003e\n\u003ctd\u003e12.40 kW \/ 3.50 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 05\u003c\/td\u003e\n\u003ctd\u003e068-2008\u003c\/td\u003e\n\u003ctd\u003e8.40 kW \/ 2.40 TR\u003c\/td\u003e\n\u003ctd\u003e16.70 kW \/ 4.80 TR\u003c\/td\u003e\n\u003ctd\u003e13.00 kW \/ 3.70 TR\u003c\/td\u003e\n\u003ctd\u003e16.50 kW \/ 4.70 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 06\u003c\/td\u003e\n\u003ctd\u003e068-2009\u003c\/td\u003e\n\u003ctd\u003e10.10 kW \/ 2.90 TR\u003c\/td\u003e\n\u003ctd\u003e19.70 kW \/ 5.60 TR\u003c\/td\u003e\n\u003ctd\u003e15.50 kW \/ 4.40 TR\u003c\/td\u003e\n\u003ctd\u003e19.70 kW \/ 5.60 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eDanfoss Rating Conditions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEvaporating temperature: 4.4°C\u003c\/li\u003e\n\u003cli\u003eCondensing temperature: 38°C\u003c\/li\u003e\n\u003cli\u003eLiquid refrigerant temperature: 37°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActual capacity may differ under other operating conditions.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name\u003c\/td\u003e\n\u003ctd\u003eOrifice for expansion valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eORF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParts program\u003c\/td\u003e\n\u003ctd\u003eT2\/TE2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed with\u003c\/td\u003e\n\u003ctd\u003eDanfoss T2 and TE2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003eSAE flare only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable sizes\u003c\/td\u003e\n\u003ctd\u003eNo. 01 to No. 06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.013 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross weight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.017-0.018 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory packing format\u003c\/td\u003e\n\u003ctd\u003eMultipack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory packing quantity\u003c\/td\u003e\n\u003ctd\u003e25 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct line\u003c\/td\u003e\n\u003ctd\u003eAir Conditioning and Commercial Refrigeration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePED category\u003c\/td\u003e\n\u003ctd\u003eArticle 4, Paragraph 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Danfoss","offers":[{"title":"No. 01 - 068-2010","offer_id":43882419257403,"sku":null,"price":137.0,"currency_code":"USD","in_stock":true},{"title":"No. 02 - 068-2015","offer_id":43882419290171,"sku":null,"price":137.0,"currency_code":"USD","in_stock":true},{"title":"No. 03 - 068-2006","offer_id":43882419322939,"sku":null,"price":137.0,"currency_code":"USD","in_stock":true},{"title":"No. 04 - 068-2007","offer_id":43882419355707,"sku":null,"price":137.0,"currency_code":"USD","in_stock":true},{"title":"No. 05 - 068-2008","offer_id":43882419388475,"sku":null,"price":137.0,"currency_code":"USD","in_stock":true},{"title":"No. 06 - 068-2009","offer_id":43882419421243,"sku":null,"price":137.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/ChatGPT_Image_Aug_10_2026_10_08_15_AM.png?v=1786327826"},{"product_id":"hongsen-th-replaceable-expansion-valve-orifices","title":"HONGSEN TH Series Replaceable Orifice Assemblies No. 1 to No. 6","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch4\u003eProduct Overview\u003c\/h4\u003e\n\u003cp\u003eHONGSEN TH Series replaceable orifice assemblies are designed for use with compatible HONGSEN TH and THW thermostatic expansion valve bodies.\u003c\/p\u003e\n\u003cp\u003eSix orifice sizes are available. Each size provides different nominal refrigeration capacities depending on whether the valve is used with R22, R134a or R404A.\u003c\/p\u003e\n\u003cp\u003eThe replaceable design allows the valve capacity to be adapted without replacing the complete thermostatic expansion valve body.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eReplaceable valve orifice assembly\u003c\/li\u003e\n\u003cli\u003eAvailable in No. 1 to No. 6 sizes\u003c\/li\u003e\n\u003cli\u003eSuitable for HONGSEN TH and THW valve bodies\u003c\/li\u003e\n\u003cli\u003eCapacity selection for R22, R134a and R404A\u003c\/li\u003e\n\u003cli\u003eIntegrated filter component\u003c\/li\u003e\n\u003cli\u003eSimplifies maintenance and capacity adjustment\u003c\/li\u003e\n\u003cli\u003eOrifice selected according to refrigerant and operating capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable Variants\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOrifice\u003c\/th\u003e\n\u003cth\u003eStock No.\u003c\/th\u003e\n\u003cth\u003eModel Code\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 1\u003c\/td\u003e\n\u003ctd\u003e01.32.239\u003c\/td\u003e\n\u003ctd\u003eTH22-09-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 2\u003c\/td\u003e\n\u003ctd\u003e01.32.240\u003c\/td\u003e\n\u003ctd\u003eTH22-09-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 3\u003c\/td\u003e\n\u003ctd\u003e01.32.241\u003c\/td\u003e\n\u003ctd\u003eTH22-09-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 4\u003c\/td\u003e\n\u003ctd\u003e01.32.242\u003c\/td\u003e\n\u003ctd\u003eTH22-09-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 5\u003c\/td\u003e\n\u003ctd\u003e01.32.243\u003c\/td\u003e\n\u003ctd\u003eTH22-09-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 6\u003c\/td\u003e\n\u003ctd\u003e01.32.244\u003c\/td\u003e\n\u003ctd\u003eTH22-09-06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eNominal Refrigeration Capacity\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOrifice\u003c\/th\u003e\n\u003cth\u003eR22 TR\u003c\/th\u003e\n\u003cth\u003eR22 kW\u003c\/th\u003e\n\u003cth\u003eR134a TR\u003c\/th\u003e\n\u003cth\u003eR134a kW\u003c\/th\u003e\n\u003cth\u003eR404A TR\u003c\/th\u003e\n\u003cth\u003eR404A kW\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 1\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e1.8\u003c\/td\u003e\n\u003ctd\u003e0.45\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 2\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003ctd\u003e0.8\u003c\/td\u003e\n\u003ctd\u003e2.6\u003c\/td\u003e\n\u003ctd\u003e0.6\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 3\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003e4.6\u003c\/td\u003e\n\u003ctd\u003e1.2\u003c\/td\u003e\n\u003ctd\u003e4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 4\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003ctd\u003e8.0\u003c\/td\u003e\n\u003ctd\u003e1.9\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003ctd\u003e1.7\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 5\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003e8.6\u003c\/td\u003e\n\u003ctd\u003e2.2\u003c\/td\u003e\n\u003ctd\u003e7.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 6\u003c\/td\u003e\n\u003ctd\u003e4.5\u003c\/td\u003e\n\u003ctd\u003e15.5\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003ctd\u003e2.6\u003c\/td\u003e\n\u003ctd\u003e9.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the following HONGSEN valve bodies:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTH22 and TH22W\u003c\/li\u003e\n\u003cli\u003eTH134 and TH134W\u003c\/li\u003e\n\u003cli\u003eTH404 and TH404W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe model codes use the \u003ccode dir=\"ltr\"\u003eTH22-09\u003c\/code\u003e prefix, but the numbered orifices are selected across the TH family according to refrigerant and required capacity.\u003c\/p\u003e\n\u003ch3\u003eImportant Selection Notice\u003c\/h3\u003e\n\u003cp\u003eNominal capacities are reference values under the manufacturer’s stated rating conditions. The final orifice must be selected according to refrigerant, evaporating temperature, condensing temperature, superheat, subcooling and required system capacity.\u003c\/p\u003e","brand":"HONGSEN","offers":[{"title":"No. 1","offer_id":44024254332987,"sku":null,"price":3.0,"currency_code":"USD","in_stock":true},{"title":"No. 2","offer_id":44024254365755,"sku":null,"price":3.0,"currency_code":"USD","in_stock":true},{"title":"No. 3","offer_id":44024254398523,"sku":null,"price":3.0,"currency_code":"USD","in_stock":true},{"title":"No. 4","offer_id":44024254431291,"sku":null,"price":3.0,"currency_code":"USD","in_stock":true},{"title":"No. 5","offer_id":44024254464059,"sku":null,"price":3.0,"currency_code":"USD","in_stock":true},{"title":"No. 6","offer_id":44024254496827,"sku":null,"price":3.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-21_144959_082.png?v=1787297080"},{"product_id":"hongsen-hv-series-refrigeration-solenoid-valve-coils","title":"HONGSEN HV Series 9W Refrigeration Solenoid Valve Coils","description":"\u003ch2\u003ePRODUCT DESCRIPTION\u003c\/h2\u003e\n\u003cp\u003eHONGSEN HV Series replacement solenoid coils are designed for compatible HONGSEN HV refrigeration solenoid valves.\u003c\/p\u003e\n\u003cp\u003eThe coils use a standard three-wire insert-type connector and may be supplied separately from the valve body. Multiple AC and DC voltage versions are available for replacement, servicing and system configuration.\u003c\/p\u003e\n\u003cp\u003eThe coil voltage and frequency must match the electrical supply and the compatible valve assembly. Verify the original coil label and valve model before ordering.\u003c\/p\u003e\n\u003ch2\u003eKEY FEATURES\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReplacement coil for compatible HONGSEN HV solenoid valves\u003c\/li\u003e\n\u003cli\u003eCan be supplied separately from the valve body\u003c\/li\u003e\n\u003cli\u003eNominal coil power of 9 W\u003c\/li\u003e\n\u003cli\u003eStandard three-wire insert connector\u003c\/li\u003e\n\u003cli\u003eAC and DC voltage options\u003c\/li\u003e\n\u003cli\u003eCoil ambient temperature range from −40°C to +65°C\u003c\/li\u003e\n\u003cli\u003eDesigned for refrigeration and air-conditioning applications\u003c\/li\u003e\n\u003cli\u003eSuitable for maintenance and replacement requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTECHNICAL SPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 41.3735%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 58.2915%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.3735%;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"width: 58.2915%;\"\u003eRefrigeration Solenoid Valve Coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.3735%;\"\u003eCompatible Series\u003c\/td\u003e\n\u003ctd style=\"width: 58.2915%;\"\u003eHONGSEN HV Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.3735%;\"\u003eNominal Power\u003c\/td\u003e\n\u003ctd style=\"width: 58.2915%;\"\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.3735%;\"\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 58.2915%;\"\u003e−40°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.3735%;\"\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"width: 58.2915%;\"\u003eStandard three-wire insert connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.3735%;\"\u003eAllowable Voltage Variation\u003c\/td\u003e\n\u003ctd style=\"width: 58.2915%;\"\u003e+10% \/ −10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.3735%;\"\u003ePublished AC Frequencies\u003c\/td\u003e\n\u003ctd style=\"width: 58.2915%;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.3735%;\"\u003eApproximate Coil Weight\u003c\/td\u003e\n\u003ctd style=\"width: 58.2915%;\"\u003e220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.3735%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 58.2915%;\"\u003eZhejiang Hongsen Machinery Co., Ltd.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.3735%;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 58.2915%;\"\u003eHONGSEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCONFIRMED VARIANTS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\u003ccode\u003eAC220V 50\/60Hz\n\u003c\/code\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\u003ccode\u003eAC380V 50\/60Hz\n\u003c\/code\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\u003ccode\u003eAC110V 50\/60Hz\n\u003c\/code\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003ccode\u003eDC24V\u003c\/code\u003e\u003ccode\u003e\u003c\/code\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch2\u003eINSTALLATION NOTES\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect the electrical supply before installation.\u003c\/li\u003e\n\u003cli\u003eMatch the coil voltage and frequency to the control circuit.\u003c\/li\u003e\n\u003cli\u003eConfirm compatibility with the installed HV valve body.\u003c\/li\u003e\n\u003cli\u003eDo not energize a loose coil unless permitted by the manufacturer.\u003c\/li\u003e\n\u003cli\u003eInstallation should be performed by a qualified refrigeration technician.\u003c\/li\u003e\n\u003cli\u003eCheck the original product label before replacing an existing coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"HONGSEN","offers":[{"title":"AC220V 50\/60Hz","offer_id":44044417826875,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"AC380V 50\/60Hz","offer_id":44044417859643,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"AC110V 50\/60Hz","offer_id":44044417892411,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true},{"title":"DC24V","offer_id":44044417925179,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-26_165538_793.png?v=1787734686"},{"product_id":"hongsen-model-10-solenoid-valve-coils","title":"HONGSEN Model 10 Replacement Solenoid Valve Coils","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eReplacement solenoid coils designed for compatible HONGSEN Model 10 refrigeration solenoid valves.\u003c\/p\u003e\n\u003cp\u003eHONGSEN Model 10 valve bodies and coils can be supplied separately, allowing the coil to be replaced without purchasing a complete valve assembly.\u003c\/p\u003e\n\u003cp\u003eThese coils are available in AC220V and AC380V, 50 Hz configurations. The valve series, voltage, frequency and electrical connection must be confirmed before ordering.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for HONGSEN Model 10 solenoid valves\u003c\/li\u003e\n\u003cli\u003e8 W rated coil\u003c\/li\u003e\n\u003cli\u003eAC220V and AC380V options\u003c\/li\u003e\n\u003cli\u003eStandard 50 Hz configuration\u003c\/li\u003e\n\u003cli\u003eStandard three-wire plug-in connector\u003c\/li\u003e\n\u003cli\u003eSuitable for replacement and maintenance\u003c\/li\u003e\n\u003cli\u003eCoil supplied separately from the valve body\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAvailable Variants\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eRated Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC220V\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003ctd\u003e8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC380V\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003ctd\u003e8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Series\u003c\/td\u003e\n\u003ctd\u003eHONGSEN Model 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Voltage\u003c\/td\u003e\n\u003ctd\u003eAC220V or AC380V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Tolerance\u003c\/td\u003e\n\u003ctd\u003e+10% \/ −15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eStandard three-wire plug-in connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eSolenoid coil only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eCompatibility Notice\u003c\/h2\u003e\n\u003cp\u003eConfirm the complete valve model and the original coil voltage before ordering. Voltage alone must not be used to determine compatibility.\u003c\/p\u003e","brand":"HONGSEN","offers":[{"title":"AC220V","offer_id":44048524935227,"sku":null,"price":5.0,"currency_code":"USD","in_stock":true},{"title":"AC380V","offer_id":44048524967995,"sku":null,"price":5.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/2026-08-27_100736_309.png?v=1787796504"},{"product_id":"hengsen-air-conditioning-service-valve-caps","title":"HENGSEN Replacement Caps for Air Conditioning Service Valves","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese \u003cstrong\u003eHENGSEN replacement valve caps\u003c\/strong\u003e are available for matching air conditioning service valves. They provide a replacement for a missing or damaged cap and cover the valve access area.\u003c\/p\u003e\n\u003cp\u003eFour fitment options are listed: a \u003cstrong\u003eshared cap for matching 1\/4\" and 3\/8\" valves\u003c\/strong\u003e, plus separate options for \u003cstrong\u003e1\/2\", 5\/8\" and 3\/4\" valves\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe size labels refer to the \u003cstrong\u003eassociated valve connection size\u003c\/strong\u003e, not the cap’s thread diameter. Match the replacement cap to the original valve’s thread and seating dimensions before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Valve Cap\u003c\/strong\u003e\u003cbr\u003eSupplied as a separate accessory for matching HENGSEN air conditioning service valves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFour Fitment Options\u003c\/strong\u003e\u003cbr\u003eChoose the shared 1\/4\"–3\/8\" valve option, or the 1\/2\", 5\/8\" or 3\/4\" valve option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMetal Construction\u003c\/strong\u003e\u003cbr\u003eA metal cap with a hexagonal exterior, as shown in the product images.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFitment-Based Selection\u003c\/strong\u003e\u003cbr\u003eSelect according to the matching valve size and confirm the original cap dimensions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHENGSEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eReplacement Air Conditioning Service Valve Cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Scope\u003c\/td\u003e\n\u003ctd\u003eCap Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Fitment Options\u003c\/td\u003e\n\u003ctd\u003eFor 1\/4\"–3\/8\" \/ 1\/2\" \/ 5\/8\" \/ 3\/4\" Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShared Fitment Option\u003c\/td\u003e\n\u003ctd\u003eOne Listed Cap Option for Matching 1\/4\" and 3\/8\" Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior Form\u003c\/td\u003e\n\u003ctd\u003eHexagonal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility Check\u003c\/td\u003e\n\u003ctd\u003eOriginal Valve Thread and Cap Seating Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable Sizes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eMatching Valve Connection Size\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFor 1\/4\" \u0026amp; 3\/8\" Valves\u003c\/td\u003e\n\u003ctd\u003eShared Listed Fitment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFor 1\/2\" Valves\u003c\/td\u003e\n\u003ctd\u003e1\/2\" Valve Fitment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFor 5\/8\" Valves\u003c\/td\u003e\n\u003ctd\u003e5\/8\" Valve Fitment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFor 3\/4\" Valves\u003c\/td\u003e\n\u003ctd\u003e3\/4\" Valve Fitment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSelection Guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the valve connection size to identify the listed cap option, then compare the replacement with the original cap’s thread diameter, pitch, depth and seating arrangement.\u003c\/p\u003e\n\u003cp\u003eThe shared 1\/4\"–3\/8\" option applies to the matching valves in this range. It does not establish universal compatibility with every valve of those pipe sizes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest a Quotation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSend the matching valve size, required quantity and a photo or dimensions of the original cap. We can review the fitment information before confirming the order.\u003c\/p\u003e","brand":"HENGSEN","offers":[{"title":"For 1\/4\" \u0026 3\/8\" Valves","offer_id":44212360937531,"sku":null,"price":1.0,"currency_code":"USD","in_stock":true},{"title":"For 1\/2\" Valves","offer_id":44212360970299,"sku":null,"price":1.0,"currency_code":"USD","in_stock":true},{"title":"For 5\/8\" Valves","offer_id":44212361003067,"sku":null,"price":1.0,"currency_code":"USD","in_stock":true},{"title":"For 3\/4\" Valves","offer_id":44212361035835,"sku":null,"price":2.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/Codex_2026_9_18_08_59_42.png?v=1789693498"}],"url":"https:\/\/xiaxuecoldroom.com\/collections\/valve-parts-accessories\/hengsen.oembed","provider":"XIAXUE Refrigeration","version":"1.0","type":"link"}