{"title":"Liquid Receiver Valves","description":null,"products":[{"product_id":"hpeok-pk-6110-liquid-receiver-valves","title":"HPEOK PK-6110 Liquid Receiver Valves - SAE Flare and NPT","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHPEOK PK-6110 liquid receiver valves provide threaded valve connections for commercial refrigeration and air-conditioning systems. This selection includes PK-6110\/22 and PK-6110\/32, both listed as vertical-type receiver valves in the manufacturer’s catalogue.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach model combines a brass valve body, a side SAE flare line connection and a bottom NPT connection shown in the factory drawing. Select the complete model by checking both connection standards, the required flow coefficient and the available installation space.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSAE Flare and NPT Connections\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePK-6110\/22 has a 1\/4-inch SAE flare inlet connection and a 1\/4-inch NPT connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePK-6110\/32 has a 3\/8-inch SAE flare inlet connection and a 1\/4-inch NPT connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBoth models therefore have the same nominal NPT receiver-connection size. The SAE flare line connection is the connection that changes between these two models.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSAE flare and NPT identify different connection standards and sealing arrangements. A connection described only as “1\/4 inch” is insufficient to establish fitment. Check the flare connection and receiver thread separately when selecting a replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe SAE flare sizes correspond to nominal tube outside diameters of 6.35 mm for 1\/4 inch and 9.525 mm for 3\/8 inch. These values describe the corresponding tube sizes, not the threaded-end outside diameters. The 1\/4 NPT designation is a nominal pipe-thread size and should not be treated as a 6.35 mm thread diameter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBrass Valve Body\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer specifies a brass valve body for this receiver-valve series. The factory photograph and drawing show threaded connections and a capped stem arrangement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe referenced catalogue page does not identify the exact brass alloy, seal compound, spindle material or cap material. Any material requirements for a specific application should be confirmed against the supplied product specification.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWorking Pressure and Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe maximum working pressure is 4.8 MPa, equivalent to 48 bar.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe published working-temperature range is −40°C to +130°C. Check these limits together with the actual refrigerant and system operating conditions when selecting the valve.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRefrigerant Applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer lists CFC, HCFC and HFC refrigerants, including R410A, for commercial refrigeration and civil and industrial air-conditioning installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor a refrigerant outside the manufacturer’s stated groups, provide the exact refrigerant designation and operating conditions for application confirmation. The referenced page does not provide a separate detailed oil-compatibility list.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eKv Flow Coefficient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe catalogue Kv factor is:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePK-6110\/22:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0.44 m³\/h\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePK-6110\/32:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1.35 m³\/h\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eKv is a valve flow coefficient used in sizing. These entries are not guaranteed refrigerant flow rates, compressor capacities or cooling outputs. Actual flow and pressure drop depend on the fluid and operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDimensions and Installation Clearance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSAE Flare Connection\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eNPT Connection\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eKv Factor\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eL1\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eL2\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eL\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePK-6110\/22\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.44 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e72 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e48 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e27.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePK-6110\/32\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.35 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e77 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eThe factory drawing defines the dimensions as follows:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eL1:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Overall valve height.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eL2:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Distance from the top of the cap to the side-connection centreline.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eL:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Distance from the bottom NPT-connection axis to the end of the side connection.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eDimension L is not the complete valve width.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUse the original drawing to check receiver clearance and access to the connections and stem. The catalogue’s “vertical type” designation identifies the PK-6110 design; final mounting should follow the instructions for the supplied valve and receiver assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHPEOK\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePK-6110\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLiquid Receiver Valve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCatalogue Design\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Models\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePK-6110\/22 and PK-6110\/32\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eValve Body Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBrass\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Working Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.8 MPa \/ 48 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWorking Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−40°C to +130°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommercial refrigeration and civil\/industrial air conditioning\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCatalogue Refrigerants\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCFC, HCFC and HFC, including R410A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLine Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSAE flare, labelled “Inlet” in the catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReceiver Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNPT, shown at the bottom of the factory drawing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNPT Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4 inch on both models\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSAE Flare Sizes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4 inch or 3\/8 inch, depending on model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKv Factors\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.44 or 1.35 m³\/h, depending on model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensional Units\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMillimetres\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight and Installation Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot published on the referenced page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSelection and Ordering\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePlease provide the complete model, quantity, required SAE flare size, required NPT thread, receiver details, refrigerant, working pressure, working temperature and delivery destination.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor replacement enquiries, include the existing valve code, photographs and dimensions. Confirm any required flare nuts or other accessories as part of the quotation, since their inclusion is not established by the referenced catalogue page.\u003c\/span\u003e\u003c\/p\u003e","brand":"HPEOK","offers":[{"title":"PK-6110\/22 - 1\/4 in SAE x 1\/4 in NPT","offer_id":44651382472763,"sku":null,"price":6.0,"currency_code":"USD","in_stock":true},{"title":"PK-6110\/32 - 3\/8 in SAE x 1\/4 in NPT","offer_id":44651382505531,"sku":null,"price":7.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/ChatGPT_2026_10_21_10_41_19.png?v=1792550496"}],"url":"https:\/\/xiaxuecoldroom.com\/ja\/collections\/liquid-receiver-valves.oembed","provider":"XIAXUE Refrigeration","version":"1.0","type":"link"}