{"product_id":"danfoss-t2-te2-orifice-assemblies","title":"Danfoss T2 and TE2 Replaceable Orifice Assemblies - No. 01 to No. 06","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003ch3\u003eDanfoss T2 and TE2 Orifice Assemblies\u003c\/h3\u003e\n\u003cp\u003eDanfoss replaceable orifice assemblies are designed for T2 and TE2 thermostatic expansion valves used in air-conditioning and commercial refrigeration systems.\u003c\/p\u003e\n\u003cp\u003eSix orifice sizes are available. Each size provides a different refrigerant capacity, allowing the T2 or TE2 valve to be matched to the refrigerant, evaporator capacity and operating conditions of the system.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for Danfoss T2 and TE2 thermostatic expansion valves\u003c\/li\u003e\n\u003cli\u003eReplaceable orifice assembly\u003c\/li\u003e\n\u003cli\u003eAvailable in sizes No. 01 through No. 06\u003c\/li\u003e\n\u003cli\u003eOfficial product type: ORF\u003c\/li\u003e\n\u003cli\u003eSAE flare design\u003c\/li\u003e\n\u003cli\u003eSuitable for multiple refrigerants\u003c\/li\u003e\n\u003cli\u003eTemperature range: -40°C to +10°C\u003c\/li\u003e\n\u003cli\u003eNet weight: approximately 0.013 kg per piece\u003c\/li\u003e\n\u003cli\u003eEasy identification by orifice number and Danfoss code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Refrigerants\u003c\/h3\u003e\n\u003cp\u003eAccording to the official Danfoss specifications, these orifice assemblies are listed for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eR1234yf\u003c\/li\u003e\n\u003cli\u003eR134a\/R513A\u003c\/li\u003e\n\u003cli\u003eR22\/R407C\u003c\/li\u003e\n\u003cli\u003eR23\u003c\/li\u003e\n\u003cli\u003eR236fa\u003c\/li\u003e\n\u003cli\u003eR404A\/R507A\u003c\/li\u003e\n\u003cli\u003eR407A\u003c\/li\u003e\n\u003cli\u003eR407C\u003c\/li\u003e\n\u003cli\u003eR448A\u003c\/li\u003e\n\u003cli\u003eR449A\u003c\/li\u003e\n\u003cli\u003eR452A\u003c\/li\u003e\n\u003cli\u003eR454C\u003c\/li\u003e\n\u003cli\u003eR455A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant Selection Information\u003c\/h3\u003e\n\u003cp\u003eThis listing is for the \u003cstrong\u003eorifice assembly only\u003c\/strong\u003e. The thermostatic element and valve body are not included.\u003c\/p\u003e\n\u003cp\u003eCooling capacity varies according to the refrigerant and operating conditions. Always select the orifice by confirming:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDanfoss code number\u003c\/li\u003e\n\u003cli\u003eOrifice number\u003c\/li\u003e\n\u003cli\u003eRefrigerant\u003c\/li\u003e\n\u003cli\u003eRequired refrigeration capacity\u003c\/li\u003e\n\u003cli\u003eEvaporating temperature\u003c\/li\u003e\n\u003cli\u003eCondensing temperature\u003c\/li\u003e\n\u003cli\u003eLiquid refrigerant temperature\u003c\/li\u003e\n\u003cli\u003ePressure drop across the valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe thermostatic element must also be suitable for the refrigerant used in the system.\u003c\/p\u003e\n\u003ch2\u003eRated Capacity Table\u003c\/h2\u003e\n\u003cp\u003eThe following values are Danfoss Range N rated capacities.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOrifice\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eR134a\u003c\/th\u003e\n\u003cth\u003eR22\u003c\/th\u003e\n\u003cth\u003eR404A\u003c\/th\u003e\n\u003cth\u003eR407C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 01\u003c\/td\u003e\n\u003ctd\u003e068-2010\u003c\/td\u003e\n\u003ctd\u003e2.10 kW \/ 0.59 TR\u003c\/td\u003e\n\u003ctd\u003e3.50 kW \/ 1.00 TR\u003c\/td\u003e\n\u003ctd\u003e2.60 kW \/ 0.75 TR\u003c\/td\u003e\n\u003ctd\u003e3.50 kW \/ 1.00 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 02\u003c\/td\u003e\n\u003ctd\u003e068-2015\u003c\/td\u003e\n\u003ctd\u003e2.60 kW \/ 0.73 TR\u003c\/td\u003e\n\u003ctd\u003e4.70 kW \/ 1.30 TR\u003c\/td\u003e\n\u003ctd\u003e3.70 kW \/ 1.00 TR\u003c\/td\u003e\n\u003ctd\u003e4.80 kW \/ 1.40 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 03\u003c\/td\u003e\n\u003ctd\u003e068-2006\u003c\/td\u003e\n\u003ctd\u003e4.30 kW \/ 1.20 TR\u003c\/td\u003e\n\u003ctd\u003e8.00 kW \/ 2.30 TR\u003c\/td\u003e\n\u003ctd\u003e6.30 kW \/ 1.80 TR\u003c\/td\u003e\n\u003ctd\u003e8.10 kW \/ 2.30 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 04\u003c\/td\u003e\n\u003ctd\u003e068-2007\u003c\/td\u003e\n\u003ctd\u003e6.40 kW \/ 1.80 TR\u003c\/td\u003e\n\u003ctd\u003e12.10 kW \/ 3.40 TR\u003c\/td\u003e\n\u003ctd\u003e9.90 kW \/ 2.80 TR\u003c\/td\u003e\n\u003ctd\u003e12.40 kW \/ 3.50 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 05\u003c\/td\u003e\n\u003ctd\u003e068-2008\u003c\/td\u003e\n\u003ctd\u003e8.40 kW \/ 2.40 TR\u003c\/td\u003e\n\u003ctd\u003e16.70 kW \/ 4.80 TR\u003c\/td\u003e\n\u003ctd\u003e13.00 kW \/ 3.70 TR\u003c\/td\u003e\n\u003ctd\u003e16.50 kW \/ 4.70 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. 06\u003c\/td\u003e\n\u003ctd\u003e068-2009\u003c\/td\u003e\n\u003ctd\u003e10.10 kW \/ 2.90 TR\u003c\/td\u003e\n\u003ctd\u003e19.70 kW \/ 5.60 TR\u003c\/td\u003e\n\u003ctd\u003e15.50 kW \/ 4.40 TR\u003c\/td\u003e\n\u003ctd\u003e19.70 kW \/ 5.60 TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eDanfoss Rating Conditions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEvaporating temperature: 4.4°C\u003c\/li\u003e\n\u003cli\u003eCondensing temperature: 38°C\u003c\/li\u003e\n\u003cli\u003eLiquid refrigerant temperature: 37°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActual capacity may differ under other operating conditions.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name\u003c\/td\u003e\n\u003ctd\u003eOrifice for expansion valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eORF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParts program\u003c\/td\u003e\n\u003ctd\u003eT2\/TE2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed with\u003c\/td\u003e\n\u003ctd\u003eDanfoss T2 and TE2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003eSAE flare only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable sizes\u003c\/td\u003e\n\u003ctd\u003eNo. 01 to No. 06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.013 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross weight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.017-0.018 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory packing format\u003c\/td\u003e\n\u003ctd\u003eMultipack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory packing quantity\u003c\/td\u003e\n\u003ctd\u003e25 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct line\u003c\/td\u003e\n\u003ctd\u003eAir Conditioning and Commercial Refrigeration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePED category\u003c\/td\u003e\n\u003ctd\u003eArticle 4, Paragraph 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Danfoss","offers":[{"title":"No. 01 - 068-2010","offer_id":43882419257403,"sku":null,"price":144.0,"currency_code":"USD","in_stock":true},{"title":"No. 02 - 068-2015","offer_id":43882419290171,"sku":null,"price":144.0,"currency_code":"USD","in_stock":true},{"title":"No. 03 - 068-2006","offer_id":43882419322939,"sku":null,"price":144.0,"currency_code":"USD","in_stock":true},{"title":"No. 04 - 068-2007","offer_id":43882419355707,"sku":null,"price":144.0,"currency_code":"USD","in_stock":true},{"title":"No. 05 - 068-2008","offer_id":43882419388475,"sku":null,"price":144.0,"currency_code":"USD","in_stock":true},{"title":"No. 06 - 068-2009","offer_id":43882419421243,"sku":null,"price":144.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/ChatGPT_Image_Aug_10_2026_10_08_15_AM.png?v=1786327826","url":"https:\/\/xiaxuecoldroom.com\/products\/danfoss-t2-te2-orifice-assemblies","provider":"XIAXUE Refrigeration","version":"1.0","type":"link"}