HONGSEN CVR Series Right-Angle Refrigeration Check Valves

Sale price $19.00

Go kalles this summer with this vintage navy and white striped v-neck t-shirt from the Nike. Perfect for pairing with denim and white kicks for a stylish kalles vibe.

Model: CVR-22 — 7/8 ODF
Add to Wishlist
Add to Compare

HONGSEN CVR Series Right-Angle Refrigeration Check Valves

HONGSEN CVR Series Right-Angle Refrigeration Check Valves

Description

Product Overview

HONGSEN CVR Series check valves are right-angle, one-way valves designed for refrigeration and air-conditioning piping systems where a 90-degree flow path is required.

The valve allows refrigerant to flow in one specified direction while helping prevent reverse flow. Its right-angle body configuration can simplify piping layouts in installations where straight-line space is limited.

CVR models use ODF solder connections and are suitable for liquid, suction-gas and hot-gas piping in refrigeration, cold-storage and air-conditioning equipment.

Key Features

  • Right-angle check-valve configuration
  • Prevents reverse refrigerant flow
  • ODF solder connections
  • Suitable for liquid, suction-gas and hot-gas piping
  • Low minimum opening-pressure differential
  • Reliable valve-seat and sealing performance
  • Suitable for applicable HCFC and HFC refrigerants
  • Connection sizes from 7/8 to 1-3/8 inch
  • Suitable for space-limited refrigeration piping layouts

Technical Specifications

Item Specification
Brand HONGSEN
Series CVR
Product Type Right-Angle Refrigeration Check Valve
Flow Pattern Right Angle
Connection Type ODF Solder
Applicable Refrigerants HCFC and HFC refrigerants
Medium Temperature Range −40°C to +120°C
Maximum Working Pressure 3.0 MPa
Maximum Test Pressure 4.5 MPa
Minimum Opening Differential 0.03 MPa

Model Selection

Official Model ODF Connection Internal Diameter Kv
CVR-22 7/8 ODF 19 mm 8.50 m³/h
CVR-28 1-1/8 ODF 25 mm 19.0 m³/h
CVR-35 1-3/8 ODF 32 mm 29.0 m³/h

 

Applications

  • Refrigeration liquid lines
  • Suction-gas piping
  • Hot-gas piping
  • Cold-room refrigeration systems
  • Commercial refrigeration equipment
  • Condensing units
  • Refrigerated warehouses
  • Space-limited piping installations

Installation Notes

  • Install according to the flow-direction arrow marked on the valve body.
  • Confirm that the right-angle flow direction matches the piping layout.
  • Do not exceed the stated pressure or temperature limits.
  • Protect the valve body from excessive brazing heat.
  • Confirm refrigerant compatibility before installation.
Model

CVR-22 — 7/8 ODF, CVR-28 — 1-1/8 ODF, CVR-35 — 1-3/8 ODF