{"product_id":"kaideli-gudd-r-hot-gas-defrost-unit-cooler","title":"KAIDELI GUDD-R Ceiling Unit Cooler with Hot Gas Defrost – 6.0 mm Fin Spacing","description":"\u003cp\u003e\u003cstrong\u003eGUDD-R — Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe KAIDELI GUDD-R model group provides eleven options for refrigeration projects specifying 6.0 mm fin spacing. Select the evaporator as part of the complete refrigeration system, considering both normal cooling operation and the proposed defrost arrangement.\u003c\/p\u003e\n\u003cp\u003eThe required duty depends on the room’s operating pattern. Daily loading, incoming product temperature, door openings and installation layout should all be included in the equipment enquiry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCeiling-mounted configuration.\u003c\/li\u003e\n\u003cli\u003eHot gas defrost designation.\u003c\/li\u003e\n\u003cli\u003eGU-series copper\/aluminium heat exchanger.\u003c\/li\u003e\n\u003cli\u003eCoated steel enclosure and hinged outer drain pan.\u003c\/li\u003e\n\u003cli\u003eEleven model options for project selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eKAIDELI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Group\u003c\/td\u003e\n\u003ctd\u003eGUDD-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eUnit cooler \/ evaporator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eCeiling mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFin Spacing\u003c\/td\u003e\n\u003ctd\u003e6.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefrost Method\u003c\/td\u003e\n\u003ctd\u003eHot gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Options\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariant Selection\u003c\/td\u003e\n\u003ctd\u003eFull model code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinal Configuration\u003c\/td\u003e\n\u003ctd\u003eDefined by the approved technical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eModel Configuration Table\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFan quantities and nominal diameters below are decoded from the manufacturer’s model-naming rules. Confirm the actual fan specification with the selected -R configuration.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eFin Spacing (mm)\u003c\/th\u003e\n\u003cth\u003eFan Quantity — Code\u003c\/th\u003e\n\u003cth\u003eNominal Fan Ø — Code (mm)\u003c\/th\u003e\n\u003cth\u003eCoil Code\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDD452D-R\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e450\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDD502D-R\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDD552D-R\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDD602D-R\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDD602E-R\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDD602F-R\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDD632D-R\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDD632E-R\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDD603F-R\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDD633F-R\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDD633H-R\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eThe published base-model table contains a conflicting fan entry for 452D. The figures above show the naming-rule interpretation; factory confirmation is required.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance, Dimensions and Connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Status\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (kW)\u003c\/td\u003e\n\u003ctd\u003eConfirm for the selected -R model and rating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow (m³\/h)\u003c\/td\u003e\n\u003ctd\u003eModel-specific -R data required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan Power and Current\u003c\/td\u003e\n\u003ctd\u003eConfirm with the supplied motor configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \/ Phase \/ Frequency\u003c\/td\u003e\n\u003ctd\u003eConfirm with the order specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Dimensions (mm)\u003c\/td\u003e\n\u003ctd\u003eRefer to the current -R factory drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Dimensions\u003c\/td\u003e\n\u003ctd\u003eRefer to the current -R factory drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant and Defrost Connections\u003c\/td\u003e\n\u003ctd\u003eConfirm with the selected circuit arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Connection\u003c\/td\u003e\n\u003ctd\u003eConfirm with the selected drain-pan configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight (kg)\u003c\/td\u003e\n\u003ctd\u003eModel-specific -R data required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConsider this model group for cold-storage installations, food-production support storage and refrigerated distribution projects where the design specifies a 6.0 mm coil.\u003c\/p\u003e\n\u003cp\u003eIdentify storage duty and product-cooling duty separately. Products entering above their storage temperature create an additional load that must be included in the selection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow to Select Your Model\u003c\/strong\u003e\u003c\/p\u003e\n\u003col start=\"1\"\u003e\n\u003cli\u003eEstablish the room and product cooling loads.\u003c\/li\u003e\n\u003cli\u003eSpecify the refrigerant and design temperatures.\u003c\/li\u003e\n\u003cli\u003eProvide loading quantities, incoming product temperatures and operating hours.\u003c\/li\u003e\n\u003cli\u003eInclude the room layout and available installation space.\u003c\/li\u003e\n\u003cli\u003eConfirm the electrical supply and proposed hot gas defrost system.\u003c\/li\u003e\n\u003cli\u003eReview the technical selection, factory drawing and scope of supply.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"KAIDELI","offers":[{"title":"GUDD452D-R","offer_id":44197131976763,"sku":null,"price":850.0,"currency_code":"USD","in_stock":true},{"title":"GUDD502D-R","offer_id":44197132009531,"sku":null,"price":969.0,"currency_code":"USD","in_stock":true},{"title":"GUDD552D-R","offer_id":44197132042299,"sku":null,"price":1068.0,"currency_code":"USD","in_stock":true},{"title":"GUDD602D-R","offer_id":44197132075067,"sku":null,"price":1117.0,"currency_code":"USD","in_stock":true},{"title":"GUDD602E-R","offer_id":44197132107835,"sku":null,"price":1396.0,"currency_code":"USD","in_stock":true},{"title":"GUDD602F-R","offer_id":44197132140603,"sku":null,"price":1515.0,"currency_code":"USD","in_stock":true},{"title":"GUDD632D-R","offer_id":44197132173371,"sku":null,"price":1598.0,"currency_code":"USD","in_stock":true},{"title":"GUDD632E-R","offer_id":44197132206139,"sku":null,"price":1756.0,"currency_code":"USD","in_stock":true},{"title":"GUDD603F-R","offer_id":44197132238907,"sku":null,"price":2039.0,"currency_code":"USD","in_stock":true},{"title":"GUDD633F-R","offer_id":44197132271675,"sku":null,"price":2298.0,"currency_code":"USD","in_stock":true},{"title":"GUDD633H-R","offer_id":44197132304443,"sku":null,"price":2714.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/GUDD-R_2694d6e2-96af-4093-a63e-f85cf572ebfa.png?v=1789441484","url":"https:\/\/xiaxuecoldroom.com\/products\/kaideli-gudd-r-hot-gas-defrost-unit-cooler","provider":"XIAXUE Refrigeration","version":"1.0","type":"link"}