{"product_id":"kaideli-gudj-r-hot-gas-defrost-unit-cooler","title":"KAIDELI GUDJ-R Ceiling Unit Cooler with Hot Gas Defrost – 9.0 mm Fin Spacing","description":"\u003cp\u003e\u003cstrong\u003eGUDJ-R — Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe KAIDELI GUDJ-R model group brings together eleven options for refrigeration designs specifying 9.0 mm fin spacing. Selection should account for cooling duty, moisture conditions and the way the room operates between defrost cycles.\u003c\/p\u003e\n\u003cp\u003eFor product-cooling or freezing projects, provide the product type, batch quantity, incoming temperature and required processing time. A selection for holding stored products should not be assumed to meet a product-freezing duty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCeiling-mounted configuration.\u003c\/li\u003e\n\u003cli\u003eHot gas defrost designation.\u003c\/li\u003e\n\u003cli\u003eGU-series copper-tube\/aluminium-fin coil.\u003c\/li\u003e\n\u003cli\u003eCoated steel casing and hinged outer drain pan.\u003c\/li\u003e\n\u003cli\u003eEleven model options in this selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eKAIDELI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Group\u003c\/td\u003e\n\u003ctd\u003eGUDJ-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eUnit cooler \/ evaporator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eCeiling mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFin Spacing\u003c\/td\u003e\n\u003ctd\u003e9.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefrost Method\u003c\/td\u003e\n\u003ctd\u003eHot gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Options\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariant Selection\u003c\/td\u003e\n\u003ctd\u003eFull model code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinal Configuration\u003c\/td\u003e\n\u003ctd\u003eDefined by the approved technical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eModel Configuration Table\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFan quantities and nominal diameters below are decoded from the manufacturer’s model-naming rules. They identify the nominal configuration and require confirmation against the selected -R factory drawing.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eFin Spacing (mm)\u003c\/th\u003e\n\u003cth\u003eFan Quantity — Code\u003c\/th\u003e\n\u003cth\u003eNominal Fan Ø — Code (mm)\u003c\/th\u003e\n\u003cth\u003eCoil Code\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDJ452D-R\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e450\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDJ502D-R\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDJ552D-R\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDJ602D-R\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDJ602E-R\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDJ602F-R\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDJ632D-R\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDJ632E-R\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDJ603F-R\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDJ633F-R\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGUDJ633H-R\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003ePublished base-model fan entries conflict with the naming rules for 452D and 502D. The figures above show the naming-rule interpretation; factory confirmation is required.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance, Dimensions and Connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Status\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (kW)\u003c\/td\u003e\n\u003ctd\u003eConfirm for the selected -R model and rating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow (m³\/h)\u003c\/td\u003e\n\u003ctd\u003eModel-specific -R data required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan Power and Current\u003c\/td\u003e\n\u003ctd\u003eConfirm with the supplied motor configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \/ Phase \/ Frequency\u003c\/td\u003e\n\u003ctd\u003eConfirm with the order specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Dimensions (mm)\u003c\/td\u003e\n\u003ctd\u003eRefer to the current -R factory drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Dimensions\u003c\/td\u003e\n\u003ctd\u003eRefer to the current -R factory drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant and Defrost Connections\u003c\/td\u003e\n\u003ctd\u003eConfirm with the selected circuit arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Connection\u003c\/td\u003e\n\u003ctd\u003eConfirm with the selected drain-pan configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Weight (kg)\u003c\/td\u003e\n\u003ctd\u003eModel-specific -R data required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConsider this model group for projects whose design calls for a 9.0 mm coil, including suitable frozen-storage and cold-chain applications.\u003c\/p\u003e\n\u003cp\u003eA specific room-temperature range or freezing rate must be established through technical selection. Include the product load, airflow requirements and intended operating cycle in the enquiry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow to Select Your Model\u003c\/strong\u003e\u003c\/p\u003e\n\u003col start=\"1\"\u003e\n\u003cli\u003eIdentify whether the duty is storage, product cooling or product freezing.\u003c\/li\u003e\n\u003cli\u003eSpecify the required duty, refrigerant and design temperatures.\u003c\/li\u003e\n\u003cli\u003eInclude product quantity, starting temperature and processing time where relevant.\u003c\/li\u003e\n\u003cli\u003eProvide the room layout, rack arrangement and available installation space.\u003c\/li\u003e\n\u003cli\u003eConfirm power supply, defrost controls and drainage requirements.\u003c\/li\u003e\n\u003cli\u003eReview the model-specific technical sheet, drawing and scope of supply.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"KAIDELI","offers":[{"title":"GUDJ452D-R","offer_id":44197174378555,"sku":null,"price":850.0,"currency_code":"USD","in_stock":true},{"title":"GUDJ502D-R","offer_id":44197174411323,"sku":null,"price":969.0,"currency_code":"USD","in_stock":true},{"title":"GUDJ552D-R","offer_id":44197174444091,"sku":null,"price":1068.0,"currency_code":"USD","in_stock":true},{"title":"GUDJ602D-R","offer_id":44197174476859,"sku":null,"price":1117.0,"currency_code":"USD","in_stock":true},{"title":"GUDJ602E-R","offer_id":44197174509627,"sku":null,"price":1396.0,"currency_code":"USD","in_stock":true},{"title":"GUDJ602F-R","offer_id":44197174542395,"sku":null,"price":1515.0,"currency_code":"USD","in_stock":true},{"title":"GUDJ632D-R","offer_id":44197174575163,"sku":null,"price":1598.0,"currency_code":"USD","in_stock":true},{"title":"GUDJ632E-R","offer_id":44197174607931,"sku":null,"price":1756.0,"currency_code":"USD","in_stock":true},{"title":"GUDJ603F-R","offer_id":44197174640699,"sku":null,"price":2039.0,"currency_code":"USD","in_stock":true},{"title":"GUDJ633F-R","offer_id":44197174673467,"sku":null,"price":2298.0,"currency_code":"USD","in_stock":true},{"title":"GUDJ633H-R","offer_id":44197174706235,"sku":null,"price":2714.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/GUDD-R_2694d6e2-96af-4093-a63e-f85cf572ebfa.png?v=1789441484","url":"https:\/\/xiaxuecoldroom.com\/products\/kaideli-gudj-r-hot-gas-defrost-unit-cooler","provider":"XIAXUE Refrigeration","version":"1.0","type":"link"}