Kaidi GU Series High-Efficiency Ceiling-Mounted Evaporators with Water Defrost

Sale price $836.00

Go kalles this summer with this vintage navy and white striped v-neck t-shirt from the Nike. Perfect for pairing with denim and white kicks for a stylish kalles vibe.

GU Series: GUDL502D-W – 4.5 mm Fin Spacing
Add to Wishlist
Add to Compare

Kaidi GU Series High-Efficiency Ceiling-Mounted Evaporators with Water Defrost

Kaidi GU Series High-Efficiency Ceiling-Mounted Evaporators with Water Defrost

Product Description

Kaidi GU Series Water-Defrost Evaporators

The Kaidi GU Series consists of high-efficiency ceiling-mounted evaporators designed for cold rooms, freezer rooms, food-processing facilities and cold-chain refrigeration applications.

All models supplied on this product page are equipped with water defrost. The water-distribution system delivers defrost water across the heat exchanger to remove frost effectively, while the large drain-pan connections support rapid discharge of defrost water.

The available models use 500 mm, 600 mm or 630 mm fan configurations, with two, three or four fans depending on the selected model. Fin spacings of 4.5 mm, 6.0 mm and 9.0 mm are available for different operating temperatures and frost conditions.

As a Kaidi distributor, we supply the GUDL-W, GUDD-W and GUDJ-W ranges. Model-selection support is available according to cooling load, room temperature, refrigerant, power supply, defrost-water supply and drainage conditions.

Key Features

  • High-efficiency ceiling-mounted evaporator
  • Water-defrost system included as standard
  • Uniform water distribution across the heat exchanger
  • Dedicated defrost-water inlet
  • Large drain connection for rapid water discharge
  • 500 mm, 600 mm and 630 mm fan configurations
  • Two-, three- or four-fan arrangements
  • 4.5 mm, 6.0 mm and 9.0 mm fin-spacing options
  • Long air throw for medium and large cold rooms
  • Powder-coated steel casing
  • Optional aluminium or stainless-steel casing
  • Alloy-aluminium tube plates
  • Internally grooved heat-exchange tubes
  • Corrugated aluminium fins
  • External-rotor fan motors with Class F insulation
  • Angled drain-pan design
  • Factory assembled and tested
  • Suitable for medium- and low-temperature refrigeration

Technical Overview

Specification Series Data
Product type High-efficiency ceiling-mounted evaporator / unit cooler
Installation Ceiling-mounted
Available series GUDL-W, GUDD-W and GUDJ-W
Defrost method Water defrost
Fan diameter 500 mm, 600 mm or 630 mm
Fan quantity 2, 3 or 4
Air volume Approximately 11,500–27,000 m³/h
Air throw Approximately 13–20 m
Cooling-capacity range Approximately 6.3–75.1 kW, depending on model and rating condition
Fin spacing 4.5 mm, 6.0 mm or 9.0 mm
Fan motor supply 3-phase, 380 V, 50 Hz – catalogue standard
Defrost-water flow Approximately 1.8–7.7 m³/h
Defrost-water inlet G1-1/2 – standard catalogue models
Drain connection G3 – standard catalogue models
Refrigerants R404A, R507A, R134a and R22
Unit weight Approximately 115–286 kg
Unit length Approximately 2,000–2,758 mm
Unit width Approximately 542–682 mm
Unit height Approximately 835–1,142 mm
Standard casing Powder-coated steel
Optional casing Aluminium or stainless steel

Important Technical Notice

Cooling capacity, airflow, dimensions, weight, water flow, water-inlet size, drainage connection and refrigerant pipe connections vary by model.

Final selection must be confirmed according to cooling load, room temperature, evaporating temperature, refrigerant, power supply, available defrost-water pressure, water flow and drainage capacity.

Series and Fin Spacing

Series Fin Spacing General Application
GUDL-W 4.5 mm Higher-temperature and fresh-storage applications
GUDD-W 6.0 mm Medium-temperature cold-storage applications
GUDJ-W 9.0 mm Low-temperature and freezer applications

Fin spacing must be selected according to room temperature, humidity, product load and expected frost accumulation.

Model Code Explanation

Example: GUDJ633H-W

Code Meaning
G G product series
U Unit cooler / air cooler code
D Ceiling-mounted installation
J 9.0 mm fin spacing
63 630 mm fan diameter
3 Three fans
H Coil specification code
W Water defrost

Other fin-spacing codes:

L = 4.5 mm
D = 6.0 mm
J = 9.0 mm

The -W suffix must be retained because it identifies the water-defrost configuration.

Standard Rating Conditions

Condition Inlet Air Temperature Evaporating Temperature Relative Humidity Superheat
SC1 10°C 0°C 85% 6.5 K
SC2 0°C −8°C 85% 5.2 K
SC3 −18°C −25°C 95% 4.6 K
SC4 −25°C −31°C 95% 3.9 K
SC5 −34°C −40°C 95% 3.9 K

Cooling-capacity values must be compared under the same rating condition and refrigerant basis.

Construction and Components

Casing

The casing is manufactured from high-quality powder-coated steel for corrosion resistance. Aluminium and stainless-steel casing materials are available for special installation environments.

Heat Exchanger

The heat exchanger uses internally grooved tubes and an optimised refrigerant-circuit layout. Alloy-aluminium tube plates help protect the copper tubes against wear caused by thermal expansion and contraction.

Aluminium Fins

Corrugated aluminium fins are used to improve air turbulence and heat-transfer performance. Fin spacings of 4.5 mm, 6.0 mm and 9.0 mm are available for different operating temperatures and frost conditions.

Fans

External-rotor fans provide stable airflow and long air throw. The standard fan motors use Class F insulation and are suitable for low-temperature refrigeration environments.

Water-Defrost System

The water-defrost system distributes water across the heat exchanger to remove frost from the coil surface. Water-inlet size and required flow depend on the selected model.

The water supply must provide sufficient pressure and flow throughout the complete defrost cycle.

Drain Pan

The drain-pan structure is designed to collect and discharge condensate and defrost water efficiently. The drainage system must be sized to handle the maximum water flow during defrosting.

Refrigerant Compatibility

R404A
R507A
R134a
R22

Actual cooling capacity must be corrected according to the selected refrigerant and operating condition.

Applications

  • Fresh-storage cold rooms
  • Chilled-food storage rooms
  • Frozen-food storage rooms
  • Walk-in coolers
  • Walk-in freezers
  • Food-processing facilities
  • Cold-chain logistics centres
  • Distribution warehouses
  • Industrial refrigeration systems
  • Applications requiring rapid removal of accumulated frost

Model Selection Information

Please provide the following information before ordering:

1. Cold-room dimensions
2. Required room temperature
3. Ambient temperature
4. Product type
5. Daily product loading quantity
6. Required cooling capacity
7. Refrigerant
8. Evaporating temperature
9. Local voltage, phase and frequency
10. Available defrost-water pressure
11. Available defrost-water flow
12. Drainage capacity
13. Maximum permitted unit dimensions

Ordering Notice

All models listed on this product page are supplied with water defrost.

Please confirm the required model, refrigerant, operating temperature, cooling capacity, electrical power supply, defrost-water pressure, water flow and drainage conditions before ordering.

Contact us if technical model-selection assistance is required.
GU Series

GUDL502D-W – 4.5 mm Fin Spacing, GUDL602D-W – 4.5 mm Fin Spacing, GUDL602E-W – 4.5 mm Fin Spacing, GUDL602F-W – 4.5 mm Fin Spacing, GUDL632D-W – 4.5 mm Fin Spacing, GUDL632E-W – 4.5 mm Fin Spacing, GUDL603F-W – 4.5 mm Fin Spacing, GUDL633F-W – 4.5 mm Fin Spacing, GUDL633H-W – 4.5 mm Fin Spacing, GUDL503D-W – 4.5 mm Fin Spacing, GUDL503E-W – 4.5 mm Fin Spacing, GUDL503F-W – 4.5 mm Fin Spacing, GUDL503EA-W – 4.5 mm Fin Spacing, GUDL503EB-W – 4.5 mm Fin Spacing, GUDL504F-W – 4.5 mm Fin Spacing, GUDL633FA-W – 4.5 mm Fin Spacing, GUDL633HA-W – 4.5 mm Fin Spacing, GUDD502D-W – 6.0 mm Fin Spacing, GUDD602D-W – 6.0 mm Fin Spacing, GUDD602E-W – 6.0 mm Fin Spacing, GUDD602F-W – 6.0 mm Fin Spacing, GUDD632D-W – 6.0 mm Fin Spacing, GUDD632E-W – 6.0 mm Fin Spacing, GUDD603F-W – 6.0 mm Fin Spacing, GUDD633F-W – 6.0 mm Fin Spacing, GUDD633H-W – 6.0 mm Fin Spacing, GUDD503D-W – 6.0 mm Fin Spacing, GUDD503E-W – 6.0 mm Fin Spacing, GUDD503F-W – 6.0 mm Fin Spacing, GUDD503EA-W – 6.0 mm Fin Spacing, GUDD503EB-W – 6.0 mm Fin Spacing, GUDD504F-W – 6.0 mm Fin Spacing, GUDD633FA-W – 6.0 mm Fin Spacing, GUDD633HA-W – 6.0 mm Fin Spacing, GUDJ502D-W – 9.0 mm Fin Spacing, GUDJ602D-W – 9.0 mm Fin Spacing, GUDJ602E-W – 9.0 mm Fin Spacing, GUDJ602F-W – 9.0 mm Fin Spacing, GUDJ632D-W – 9.0 mm Fin Spacing, GUDJ632E-W – 9.0 mm Fin Spacing, GUDJ603F-W – 9.0 mm Fin Spacing, GUDJ633F-W – 9.0 mm Fin Spacing, GUDJ633H-W – 9.0 mm Fin Spacing, GUDJ503D-W – 9.0 mm Fin Spacing, GUDJ503E-W – 9.0 mm Fin Spacing, GUDJ503F-W – 9.0 mm Fin Spacing, GUDJ503EA-W – 9.0 mm Fin Spacing, GUDJ503EB-W – 9.0 mm Fin Spacing, GUDJ504F-W – 9.0 mm Fin Spacing, GUDJ633FA-W – 9.0 mm Fin Spacing, GUDJ633HA-W – 9.0 mm Fin Spacing