{"title":"Oil Management Components","description":null,"products":[{"product_id":"hpeok-pkw-filter-type-oil-separator","title":"Separador de óleo por filtragem HPEOK PKW","description":"\u003cp\u003e\u003cstrong\u003eDescrição do produto\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOs separadores de óleo por filtragem HPEOK PKW são projetados para separar o óleo transportado pelo gás de descarga do compressor e auxiliar o gerenciamento de óleo em sistemas de refrigeração. Esta linha de produtos inclui 11 modelos PKW selecionados, com medidas de conexão de 3\/8 a 2-1\/8 polegadas e volumes dos vasos de catálogo de 1.8 a 7.8 litros.\u003c\/p\u003e\n\u003cp\u003eO separador utiliza uma tela filtrante para auxiliar a separação do óleo e uma válvula de agulha acionada por boia para controlar o retorno do óleo coletado. Ele é instalado na linha de descarga do compressor, entre o compressor e o condensador, seguindo as instruções de instalação do fabricante do equipamento.\u003c\/p\u003e\n\u003cp\u003eO catálogo especifica uma pressão de trabalho de projeto de 4.8 MPa (48 bar) e uma faixa de temperatura de operação de -10°C a +120°C. Ao selecionar um modelo, considere a medida das conexões, o volume do vaso, as dimensões de instalação e os requisitos do sistema de refrigeração.\u003c\/p\u003e\n\u003cp\u003eModelos com a mesma medida de conexão não são necessariamente intercambiáveis. Por exemplo, PKW-55855A e PKW-55855 têm conexão de 5\/8 polegada, mas suas dimensões B são de 338 mm e 378 mm, e seus volumes de vaso são de 2.2 litros e 2.5 litros, respectivamente. Mantenha sempre o número completo do modelo, incluindo o sufixo A quando aplicável.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrincipais características\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\nProjeto por filtragem para separar o óleo do gás de descarga do compressor.\n\u003c\/li\u003e\n\u003cli\u003e\nVálvula de agulha acionada por boia para retorno do óleo coletado.\n\u003c\/li\u003e\n\u003cli\u003e\nOnze opções de modelos com conexões de 3\/8 a 2-1\/8 polegadas.\n\u003c\/li\u003e\n\u003cli\u003e\nVolumes dos vasos de catálogo de 1.8 a 7.8 litros.\n\u003c\/li\u003e\n\u003cli\u003e\nPressão de trabalho de projeto: 4.8 MPa (48 bar).\n\u003c\/li\u003e\n\u003cli\u003e\nFaixa de temperatura de operação: -10°C a +120°C.\n\u003c\/li\u003e\n\u003cli\u003e\nDimensões e quantidades de carga inicial de óleo específicas por modelo.\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEspecificações técnicas\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModelo\u003c\/th\u003e\n\u003cth\u003e\nMedida da conexão\n\u003c\/th\u003e\n\u003cth\u003e\nØA (mm)\n\u003c\/th\u003e\n\u003cth\u003e\nB (mm)\n\u003c\/th\u003e\n\u003cth\u003e\nC (mm)\n\u003c\/th\u003e\n\u003cth\u003e\nVolume do vaso (L)\n\u003c\/th\u003e\n\u003cth\u003e\nCarga inicial de óleo (L)\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nPKW-55833\n\u003c\/td\u003e\n\u003ctd\u003e\n3\/8 in\n\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e279\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e\n1.8\n\u003c\/td\u003e\n\u003ctd\u003e\n0.6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nPKW-55824\n\u003c\/td\u003e\n\u003ctd\u003e\n1\/2 in\n\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e279\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e\n1.8\n\u003c\/td\u003e\n\u003ctd\u003e\n0.6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nPKW-55855A\n\u003c\/td\u003e\n\u003ctd\u003e\n5\/8 in\n\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e338\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e\n2.2\n\u003c\/td\u003e\n\u003ctd\u003e\n0.6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nPKW-55855\n\u003c\/td\u003e\n\u003ctd\u003e\n5\/8 in\n\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e378\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e\n2.5\n\u003c\/td\u003e\n\u003ctd\u003e\n0.6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nPKW-55877A\n\u003c\/td\u003e\n\u003ctd\u003e\n7\/8 in\n\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e384\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e\n2.6\n\u003c\/td\u003e\n\u003ctd\u003e\n0.6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nPKW-55877\n\u003c\/td\u003e\n\u003ctd\u003e\n7\/8 in\n\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e460\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e\n3.1\n\u003c\/td\u003e\n\u003ctd\u003e\n0.6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nPKW-55889A\n\u003c\/td\u003e\n\u003ctd\u003e\n1-1\/8 in\n\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e414\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e\n2.8\n\u003c\/td\u003e\n\u003ctd\u003e\n0.6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nPKW-55889\n\u003c\/td\u003e\n\u003ctd\u003e\n1-1\/8 in\n\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e494\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e\n3.4\n\u003c\/td\u003e\n\u003ctd\u003e\n0.6\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nPKW-569011\n\u003c\/td\u003e\n\u003ctd\u003e\n1-3\/8 in\n\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003ctd\u003e394\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e\n6.4\n\u003c\/td\u003e\n\u003ctd\u003e\n0.8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nPKW-569213\n\u003c\/td\u003e\n\u003ctd\u003e\n1-5\/8 in\n\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003ctd\u003e480\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e\n7.8\n\u003c\/td\u003e\n\u003ctd\u003e\n0.8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nPKW-569417\n\u003c\/td\u003e\n\u003ctd\u003e\n2-1\/8 in\n\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003ctd\u003e485\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e\n7.8\n\u003c\/td\u003e\n\u003ctd\u003e\n0.8\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eAs letras das dimensões correspondem ao desenho do fabricante. ØA indica o diâmetro do corpo. Consulte o desenho para as posições das dimensões B e C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeleção e instalação\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSelecione o separador de acordo com o projeto do sistema de refrigeração e os requisitos do compressor. A medida da conexão por si só não determina a adequação. Confirme a compatibilidade com o refrigerante e o lubrificante, as condições de operação e o espaço disponível para instalação.\u003c\/p\u003e\n\u003cp\u003eInstale o separador verticalmente. Verifique a orientação de entrada e saída, a disposição de montagem e o acesso para manutenção antes de conectar a tubulação.\u003c\/p\u003e\n\u003cp\u003eOs valores de carga inicial de óleo apresentados acima são quantidades de carga de catálogo. Eles não confirmam que o separador seja fornecido previamente abastecido. Utilize o lubrificante especificado para o compressor e siga as instruções de abastecimento e entrada em operação do fabricante.\u003c\/p\u003e","brand":"HPEOK","offers":[{"title":"PKW-55833","offer_id":44314194608187,"sku":null,"price":26.0,"currency_code":"USD","in_stock":true},{"title":"PKW-55824","offer_id":44314194640955,"sku":null,"price":24.0,"currency_code":"USD","in_stock":true},{"title":"PKW-55855A","offer_id":44314194673723,"sku":null,"price":34.0,"currency_code":"USD","in_stock":true},{"title":"PKW-55855","offer_id":44314194706491,"sku":null,"price":24.0,"currency_code":"USD","in_stock":true},{"title":"PKW-55877A","offer_id":44314194739259,"sku":null,"price":36.0,"currency_code":"USD","in_stock":true},{"title":"PKW-55877","offer_id":44314194772027,"sku":null,"price":31.0,"currency_code":"USD","in_stock":true},{"title":"PKW-55889A","offer_id":44314194804795,"sku":null,"price":40.0,"currency_code":"USD","in_stock":true},{"title":"PKW-55889","offer_id":44314194837563,"sku":null,"price":34.0,"currency_code":"USD","in_stock":true},{"title":"PKW-569011","offer_id":44314194870331,"sku":null,"price":54.0,"currency_code":"USD","in_stock":true},{"title":"PKW-569213","offer_id":44314194903099,"sku":null,"price":59.0,"currency_code":"USD","in_stock":true},{"title":"PKW-569417","offer_id":44314194935867,"sku":null,"price":65.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/04.png?v=1790569072"},{"product_id":"hpeok-pkw-helical-oil-separator","title":"Separador de óleo helicoidal HPEOK PKW","description":"\u003cp\u003e\u003cstrong\u003eTítulo do produto\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSeparador de óleo helicoidal HPEOK PKW\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescrição do produto\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOs separadores de óleo helicoidais HPEOK PKW utilizam um projeto de separação helicoidal para separar o óleo transportado pelo gás de descarga do compressor e auxiliar o gerenciamento de óleo do sistema de refrigeração. Esta linha de produtos inclui 13 modelos selecionados, abrangendo medidas de conexão ODF de 1\/2 a 2-5\/8 polegadas e volumes dos vasos de catálogo de 2.4 a 15.2 litros.\u003c\/p\u003e\n\u003cp\u003eO projeto helicoidal direciona o gás de descarga com óleo por um trajeto de fluxo em espiral para auxiliar a separação. O separador é instalado na linha de descarga do compressor, sendo o modelo exato selecionado conforme as condições de operação do sistema, os requisitos das conexões e o espaço disponível para instalação.\u003c\/p\u003e\n\u003cp\u003eO catálogo especifica uma pressão de trabalho de projeto de 4.7 MPa (47 bar) e uma faixa de temperatura de operação de -10°C a +120°C. A seleção do modelo deve considerar as dimensões do corpo, o volume do vaso e os requisitos de carga inicial de óleo, além da medida das conexões.\u003c\/p\u003e\n\u003cp\u003eModelos com números semelhantes podem ter especificações diferentes. Por exemplo, PKW-0611 e PKW-0611F têm conexão ODF de 1-3\/8 polegadas e diâmetro do corpo de 159 mm. No entanto, suas dimensões B são de 476 mm e 611 mm, seus volumes de vaso são de 7.8 litros e 7.5 litros, e suas quantidades de carga inicial de óleo são de 1.1 litros e 0.7 litros, respectivamente. Selecione e peça sempre o número completo do modelo, incluindo o sufixo F quando aplicável.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrincipais características\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProjeto de separação helicoidal para gerenciamento de óleo do sistema de refrigeração.\u003c\/li\u003e\n\u003cli\u003eTreze opções de modelos com conexões ODF de 1\/2 a 2-5\/8 polegadas.\u003c\/li\u003e\n\u003cli\u003eVolumes dos vasos de catálogo de 2.4 a 15.2 litros.\u003c\/li\u003e\n\u003cli\u003ePressão de trabalho de projeto: 4.7 MPa (47 bar).\u003c\/li\u003e\n\u003cli\u003eFaixa de temperatura de operação: -10°C a +120°C.\u003c\/li\u003e\n\u003cli\u003eDiversas dimensões de corpo para atender a diferentes disposições de instalação.\u003c\/li\u003e\n\u003cli\u003eVolumes de vaso e quantidades de carga inicial de óleo específicos por modelo.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEspecificações técnicas\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModelo\u003c\/th\u003e\n\u003cth\u003eConexão ODF\u003c\/th\u003e\n\u003cth\u003eØA (mm)\u003c\/th\u003e\n\u003cth\u003eB (mm)\u003c\/th\u003e\n\u003cth\u003eVolume do vaso (L)\u003c\/th\u003e\n\u003cth\u003eCarga inicial de óleo (L)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePKW-0404\u003c\/td\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e359\u003c\/td\u003e\n\u003ctd\u003e2.4\u003c\/td\u003e\n\u003ctd\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePKW-0405\u003c\/td\u003e\n\u003ctd\u003e5\/8 in\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e377\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePKW-0407\u003c\/td\u003e\n\u003ctd\u003e7\/8 in\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e434\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003ctd\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePKW-0409\u003c\/td\u003e\n\u003ctd\u003e1-1\/8 in\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e481\u003c\/td\u003e\n\u003ctd\u003e3.2\u003c\/td\u003e\n\u003ctd\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePKW-0611\u003c\/td\u003e\n\u003ctd\u003e1-3\/8 in\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003ctd\u003e476\u003c\/td\u003e\n\u003ctd\u003e7.8\u003c\/td\u003e\n\u003ctd\u003e1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePKW-0611F\u003c\/td\u003e\n\u003ctd\u003e1-3\/8 in\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003ctd\u003e611\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePKW-0613\u003c\/td\u003e\n\u003ctd\u003e1-5\/8 in\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003ctd\u003e476\u003c\/td\u003e\n\u003ctd\u003e7.8\u003c\/td\u003e\n\u003ctd\u003e1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePKW-0613F\u003c\/td\u003e\n\u003ctd\u003e1-5\/8 in\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003ctd\u003e611\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePKW-0813F\u003c\/td\u003e\n\u003ctd\u003e1-5\/8 in\u003c\/td\u003e\n\u003ctd\u003e219\u003c\/td\u003e\n\u003ctd\u003e671\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePKW-0617\u003c\/td\u003e\n\u003ctd\u003e2-1\/8 in\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003ctd\u003e482\u003c\/td\u003e\n\u003ctd\u003e7.8\u003c\/td\u003e\n\u003ctd\u003e1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePKW-0617F\u003c\/td\u003e\n\u003ctd\u003e2-1\/8 in\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003ctd\u003e617\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePKW-0817F\u003c\/td\u003e\n\u003ctd\u003e2-1\/8 in\u003c\/td\u003e\n\u003ctd\u003e219\u003c\/td\u003e\n\u003ctd\u003e678\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePKW-0821F\u003c\/td\u003e\n\u003ctd\u003e2-5\/8 in\u003c\/td\u003e\n\u003ctd\u003e219\u003c\/td\u003e\n\u003ctd\u003e678\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eAs letras das dimensões correspondem ao desenho do fabricante. ØA indica o diâmetro do corpo. Consulte o desenho original para a dimensão B e as dimensões adicionais de conexão e montagem aplicáveis a cada modelo.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeleção e instalação\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirme a adequação do separador selecionado ao refrigerante, ao lubrificante do compressor e à carga de operação. Compare a especificação completa do modelo com o projeto do sistema antes do pedido.\u003c\/p\u003e\n\u003cp\u003eInstale o separador verticalmente na linha de descarga do compressor, seguindo as instruções do fabricante do equipamento. Verifique a orientação das conexões, a disposição de montagem, as folgas da tubulação e o acesso para manutenção.\u003c\/p\u003e\n\u003cp\u003eA coluna de carga inicial de óleo indica a quantidade de carga de catálogo de cada modelo. Ela não confirma que o óleo esteja incluído no produto. Utilize o lubrificante especificado pelo fabricante do compressor e siga as instruções aplicáveis de abastecimento e entrada em operação.\u003c\/p\u003e","brand":"HPEOK","offers":[{"title":"PKW-0404","offer_id":44314236256315,"sku":null,"price":40.0,"currency_code":"USD","in_stock":true},{"title":"PKW-0405","offer_id":44314236289083,"sku":null,"price":45.0,"currency_code":"USD","in_stock":true},{"title":"PKW-0407","offer_id":44314236321851,"sku":null,"price":50.0,"currency_code":"USD","in_stock":true},{"title":"PKW-0409","offer_id":44314236354619,"sku":null,"price":58.0,"currency_code":"USD","in_stock":true},{"title":"PKW-0611","offer_id":44314236387387,"sku":null,"price":70.0,"currency_code":"USD","in_stock":true},{"title":"PKW-0611F","offer_id":44314236420155,"sku":null,"price":102.0,"currency_code":"USD","in_stock":true},{"title":"PKW-0613","offer_id":44314236452923,"sku":null,"price":76.0,"currency_code":"USD","in_stock":true},{"title":"PKW-0613F","offer_id":44314236485691,"sku":null,"price":107.0,"currency_code":"USD","in_stock":true},{"title":"PKW-0813F","offer_id":44314236518459,"sku":null,"price":196.0,"currency_code":"USD","in_stock":true},{"title":"PKW-0617","offer_id":44314236551227,"sku":null,"price":84.0,"currency_code":"USD","in_stock":true},{"title":"PKW-0617F","offer_id":44314236583995,"sku":null,"price":112.0,"currency_code":"USD","in_stock":true},{"title":"PKW-0817F","offer_id":44314236616763,"sku":null,"price":206.0,"currency_code":"USD","in_stock":true},{"title":"PKW-0821F","offer_id":44314236649531,"sku":null,"price":229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/Codex_2026_9_28_11_56_02.png?v=1790567805"},{"product_id":"hpeok-pkg-refrigeration-oil-filters-sae-flare","title":"HPEOK PKG Refrigeration Oil Filters – SAE Flare Connections","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHPEOK PKG series oil filters are designed for refrigeration oil-management circuits, helping remove suspended particles from oil returning through the system. This selection includes PKG-083, PKG-084 and PKG-085 with SAE flare connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSelect the complete model and connection size to match the oil line. The three models share the catalogue’s B and diameter dimensions, while their overall A dimensions differ.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eParticle Filtration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer states that PKG filters retain 99% of 3-micrometre particles. This is a manufacturer-stated filtration performance figure; the referenced catalogue page does not provide an absolute or nominal filter classification or a test standard.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe filtration function helps support oil cleanliness in circuits supplying oil-management components and compressors. The catalogue describes a design intended to provide filtration while maintaining flow with a low pressure drop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOil and Refrigerant Applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe HPEOK catalogue identifies HFC and HCFC refrigerants and their associated oils. It specifically discusses PKG use in POE-oil systems, while the manufacturer’s earlier product information also identifies mineral oil.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProvide the actual oil, refrigerant and system operating conditions when requesting a filter so the required application can be checked. Oil grade, viscosity and operating conditions should be considered during equipment selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSAE Flare Connections\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePKG-083 has a 3\/8-inch SAE flare connection, PKG-084 has a 1\/2-inch SAE flare connection, and PKG-085 has a 5\/8-inch SAE flare connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese sizes identify the nominal flare tube connections. They are separate from the filter-body diameter and do not describe a BSP or NPT pipe-thread size.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe selected models do not carry an S suffix. Retain the complete product code when ordering to identify the required connection version.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eConstruction and Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer catalogue states that the pressure-bearing components, including the shell, caps and connection fittings, are carbon steel. The internal spring is steel.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstallation dimensions are provided as A, B and diameter D. Use these values together with the factory drawing when checking installation space and replacement compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConnection size alone does not determine overall length. PKG-083, PKG-084 and PKG-085 have different A dimensions despite sharing the same listed B and diameter D values.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWorking Pressure and Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe maximum working pressure is 35 bar, equivalent to 3.5 MPa. The catalogue also lists this as 507 PSI.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe allowable operating temperature is −10°C to +100°C. The referenced page provides this operating range without separate ambient and fluid temperature ratings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation and Service\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstall the filter according to its marked flow-direction arrow. For low-pressure oil-management systems, the manufacturer identifies the arrangement as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOil Separator → PKG Oil Filter → Oil Receiver\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe catalogue recommends isolation valves on either side to ease replacement. Valves and associated installation components are supplied only where included in the quotation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer’s replacement criterion is a pressure drop of 15 PSI, approximately 1 bar, across the filter. This differential-pressure criterion is separate from the maximum working-pressure rating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eModel Selection and Quotation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCheck the connection size, installation dimensions, oil and refrigerant application, and operating conditions before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePlease provide your required model, quantity, delivery destination and application details when requesting a quotation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHPEOK\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePKG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefrigeration Oil Filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSelected Models\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePKG-083, PKG-084, PKG-085\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSAE Flare\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Sizes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8″, 1\/2″ and 5\/8″\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer-Stated Filtration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e99% of 3 μm particles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFiltration Test Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot stated on the referenced catalogue page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Working Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 bar \/ 3.5 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCatalogue Pressure in PSI\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e507 PSI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAllowable Operating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−10°C to +100°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRefrigerant Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHFC and HCFC refrigerants and associated oils\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOil Applications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOE; mineral oil also identified in earlier manufacturer information\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure-Bearing Components\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCarbon steel shell, caps and connection fittings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Spring\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSteel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation Direction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccording to the marked flow arrow\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLow-Pressure System Location\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBetween oil separator and oil receiver\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer Replacement Criterion\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePressure drop of approximately 1 bar \/ 15 PSI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimension Units\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003emm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eModel Connections and Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSAE Flare Connection\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eA\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eB\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eØD\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKG-083\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8″\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e155 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e98 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKG-084\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2″\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e163 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e98 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKG-085\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5\/8″\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e146 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e98 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eA, B and ØD correspond to the positions shown in the manufacturer’s dimension drawing.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCatalogue Refrigeration-Capacity Reference\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eR404A \/ R507\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eR22 \/ R407C\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eR134a\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eR410A\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKG-083\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.7 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23.7 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21.8 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36.0 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKG-084\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.7 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23.7 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21.8 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36.0 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKG-085\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.8 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.8 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e27.4 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45.2 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eThese are manufacturer catalogue refrigeration-capacity references. They do not describe cooling output produced by the filter or oil flow in L\/min. Rating conditions are not stated on the referenced page; confirm application before using these values for selection.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"HPEOK","offers":[{"title":"PKG-083 - 3\/8 in SAE Flare","offer_id":44641042956347,"sku":null,"price":11.0,"currency_code":"USD","in_stock":true},{"title":"PKG-084 - 1\/2 in SAE Flare","offer_id":44641042989115,"sku":null,"price":12.0,"currency_code":"USD","in_stock":true},{"title":"PKG-085 - 5\/8 in SAE Flare","offer_id":44641043021883,"sku":null,"price":13.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/ChatGPT_2026_10_20_14_16_52.png?v=1792477060"},{"product_id":"hpeok-pkolc-mechanical-oil-level-regulators","title":"HPEOK PKOLC Mechanical Oil Level Regulators – Fixed and Adjustable","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHPEOK PKOLC mechanical oil level regulators control the oil level in refrigeration compressor crankcases. Designed for low-pressure oil-management systems on parallel compressor racks, the regulators mount directly to a compatible compressor sight-glass housing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe range includes the fixed-level PKOLC-2 and the adjustable PKOLC-2-5 and PKOLC-2-5E. Model selection depends on the required crankcase oil level, operating oil-pressure differential, compressor flange and equalization requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAdapters are available for different compressor models. The required adapter and its inclusion in the supply must be confirmed when ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePKOLC-2: Fixed Oil Level\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePKOLC-2 maintains a fixed oil level at one-half of the sight glass. The manufacturer describes a float-operated valve that admits oil from the oil receiver when the level falls and closes when the required level is restored.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts specified operating differential pressure is 0.35–2.0 bar. The catalogue lists no equalization connection and identifies the connection designation as “5 bolts”.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe one-half value describes the oil level in the sight glass. It does not indicate a half-inch pipe connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePKOLC-2-5: Adjustable Oil Level\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePKOLC-2-5 provides an adjustable oil level from one-quarter to five-eighths of the sight glass, equivalent to 25%–62.5% of the sight-glass level.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe adjustable setting allows the regulator to be commissioned according to the compressor manufacturer’s oil-level requirement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts specified operating differential pressure is 0.35–6.2 bar. The catalogue lists no equalization connection and gives the connection designation as “7 bolts”.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePKOLC-2-5E: Adjustable Oil Level with Equalization\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePKOLC-2-5E provides the same one-quarter to five-eighths adjustable oil-level range and 0.35–6.2 bar operating differential-pressure range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer’s model table identifies an equalization connection for this version. It also marks PKOLC-2-5E as YES under the column “Suitable with R717 \u0026amp; HP”, while the other two models are marked NO.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHP is not defined on the referenced catalogue page. Confirm the actual refrigerant, oil and application during selection. This entry does not establish a working-pressure rating above the stated 32 bar maximum.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAll three selected models are classified as mechanical oil level regulators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWorking Pressure and Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe maximum working pressure is 32 bar, equivalent to 3.2 MPa. The catalogue also expresses this rating as 464 PSI.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe allowable operating temperature is −10°C to +120°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMaximum working pressure and operating differential pressure are separate limits. System pressure must remain within the maximum working-pressure rating, while the operating oil-pressure differential must remain within the range specified for the selected model.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eConnections and Compressor Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe factory drawings identify a 3\/8 SAE oil-line connection. The catalogue describes SAE flare oil connections and flange mounting at the compressor crankcase sight-glass housing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCheck the compressor model, flange geometry, installation space and adapter requirements before ordering a replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe catalogue’s “5 bolts” and “7 bolts” designations do not provide complete flange-hole dimensions or establish compatibility with every compressor. Send the existing flange dimensions or photographs when requesting replacement assistance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePKOLC-2 has a body diameter of 102 mm, an overall height of 148.5 ±3 mm and a body height of 118 ±2 mm. Its sight-glass centre is shown 55 ±2 mm above the base.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe shared catalogue drawing beside PKOLC-2-5 and PKOLC-2-5E shows a body diameter of 100 mm, an overall height of 180.5 mm and a body height of 122 mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUse the original drawing to check connection clearances and local dimensions. The adjustable-model dimensions come from one shared catalogue drawing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation and Maintenance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer recommends an oil strainer, oil filter or oil filter drier to protect the regulator from system debris.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvoid excessive vibration and keep the operating differential oil pressure within the selected model’s specified range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFollow the supplied installation sheet for mounting and commissioning. The catalogue instructs installers to keep the body horizontal. Confirm the required orientation and oil level against the instructions supplied with the actual unit and the compressor manufacturer’s requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOrdering Information\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePlease provide the required model, quantity, compressor make and model, refrigerant, oil type, working pressure, operating oil-pressure differential and delivery destination.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor replacement applications, include photographs and dimensions of the existing regulator and compressor flange so that model selection and adapter requirements can be checked.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHPEOK\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePKOLC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Oil Level Regulator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-pressure oil-management systems on parallel compressor racks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Location\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompatible compressor crankcase sight-glass housing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Working Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 bar \/ 3.2 MPa \/ 464 PSI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAllowable Operating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−10°C to +120°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOil-Line Connection Shown\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8 SAE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOil-Line Connection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSAE flare\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFixed-Level Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePKOLC-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable-Level Models\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePKOLC-2-5 and PKOLC-2-5E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEqualization Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePKOLC-2-5E, according to the model table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompressor Adapters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable; exact adapter and inclusion to be confirmed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaterial, Weight and Oil Flow Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot stated on the referenced catalogue page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eModel Comparison\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eOil-Level Setting\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eOperating Differential Pressure\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eEqualization Connection\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eCatalogue Connection\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKOLC-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFixed at 1\/2 sight glass\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35–2.0 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bolts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKOLC-2-5\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable, 1\/4–5\/8 sight glass\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35–6.2 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 bolts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKOLC-2-5E\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable, 1\/4–5\/8 sight glass\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35–6.2 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 bolts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDimensions in Millimetres\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBody Diameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eOverall Height\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBody Height\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKOLC-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e102\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e148.5 ±3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e118 ±2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKOLC-2-5\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e180.5\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e122\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKOLC-2-5E\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e180.5\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e122\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003ePKOLC-2-5 and PKOLC-2-5E follow the shared adjustable-model drawing in the 2020 catalogue.\u003c\/span\u003e\u003c\/p\u003e","brand":"HPEOK","offers":[{"title":"PKOLC-2 - Fixed Oil Level","offer_id":44643151151163,"sku":null,"price":49.0,"currency_code":"USD","in_stock":true},{"title":"PKOLC-2-5 - Adjustable Oil Level","offer_id":44643151183931,"sku":null,"price":57.0,"currency_code":"USD","in_stock":true},{"title":"PKOLC-2-5E - Adjustable with Equalization","offer_id":44643151216699,"sku":null,"price":64.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/ChatGPT_2026_10_20_17_03_13.png?v=1792487261"}],"url":"https:\/\/xiaxuecoldroom.com\/pt\/collections\/oil-management-components.oembed","provider":"XIAXUE Refrigeration","version":"1.0","type":"link"}