{"title":"Discharge Mufflers","description":null,"products":[{"product_id":"hpeok-pkx-compressor-discharge-mufflers","title":"HPEOK PKX Refrigeration Discharge Mufflers – PKX-4022 and PKX-4026","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHPEOK PKX discharge mufflers help reduce pressure pulsations and the associated noise in refrigeration compressor discharge lines. Installed downstream of the compressor, the muffler uses internal baffles and expansion chambers to dampen pulsating refrigerant gas flow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis selection includes PKX-4022 with a 1-3\/8-inch ODF connection and PKX-4026 with a 1-5\/8-inch ODF connection. Both models have a catalogue body diameter of 102 mm and body-length dimension B of 280 mm. Their connection sizes and overall lengths differ, so the complete model code should be retained when ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePulsation and Noise Reduction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe internal baffles and chambers allow the discharge gas to expand and change its flow velocity, helping dampen low- and high-frequency gas pulsations. The series is designed to provide this damping with a low pressure drop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA discharge muffler addresses noise caused by gas pulsation. Mechanical vibration transmitted through the pipework requires suitable vibration isolation as part of the system design. The manufacturer recommends installing a vibration absorber between the compressor and muffler.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe referenced catalogue does not publish a guaranteed decibel-reduction figure, acoustic frequency-response curve or numerical pressure-drop curve. Selection should therefore consider the compressor and discharge-piping arrangement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eModel Selection and Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eODF Connection\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eCorresponding Tube OD*\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eOverall Length A\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBody Length B\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBody Diameter D\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKX-4022\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1-3\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e34.925 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e368 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e280 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e102 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePKX-4026\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1-5\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e41.275 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e280 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e102 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eThe millimetre tube-OD values are mathematical conversions of the inch sizes, rather than separately published metric socket-bore dimensions.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe ODF connections are intended for brazed copper-tube installation. Use the original factory drawing to interpret dimensions A, B and D and check the available installation space.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer recommends selecting a muffler connection size that matches or exceeds the compressor discharge-line size. The catalogue does not provide a compressor-horsepower or refrigeration-capacity selection table for these two models.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePressure Rating and Operating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe exact-model specification table lists a pressure rating of 3.2 MPa, equivalent to 32 bar, for both PKX-4022 and PKX-4026.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe general series introduction in the same catalogue states 34 bar. Because these entries differ, this listing uses the model-table value of 32 bar. Confirm the current supplied-unit rating against its nameplate or manufacturer documentation before final selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe allowable operating temperature in the 2020 catalogue is −40°C to +130°C. The source provides this operating range without separate fluid and ambient temperature limits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRefrigerant and Oil Applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer identifies HCFC and HFC refrigerants and their associated oils. It also refers to other industrial fluids that are non-corrosive to steel and copper.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProvide the actual refrigerant, oil and operating conditions when requesting a quotation so that application suitability can be checked. Compatibility with another refrigerant family must be confirmed separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFlow and Installation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe catalogue identifies bi-directional flow for the PKX series. Mounting orientation must still allow oil drainage and limit oil collection inside the muffler.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFollow these manufacturer installation recommendations:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eInstall close to the compressor and before the oil separator.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFor horizontal or angled installation, keep the labelled side at the top centre.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eA slight slope with the outlet below the inlet helps oil drainage.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVertical installation is also permitted in the catalogue notes.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall a vibration absorber between the compressor and muffler.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOn parallel compressor racks, a muffler may be installed in the common discharge line or individually for each compressor, depending on system design.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFollow the instructions supplied with the actual unit and provide suitable pipe support and vibration isolation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHPEOK\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePKX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefrigeration Discharge Muffler\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Models\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePKX-4022 and PKX-4026\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMain Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReduction of discharge-gas pressure pulsations and associated noise\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Operating Principle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBaffles and expansion chambers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation Location\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompressor discharge line, before the oil separator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eODF brazed connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Sizes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1-3\/8 inch and 1-5\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlow\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBi-directional, according to the catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel-Table Pressure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.2 MPa \/ 32 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAllowable Operating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−40°C to +130°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCatalogue Refrigerant Applications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHCFC and HFC refrigerants and associated oils\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBody Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e102 mm for both models\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBody-Length Dimension B\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e280 mm for both models\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverall-Length Dimension A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e368 mm \/ 380 mm, depending on model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Positions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHorizontal, angled or vertical, following installation requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGuaranteed Sound Attenuation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot published on the referenced pages\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight and Internal Volume\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot published on the referenced pages\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Material Grade and Wall Thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot published on the referenced pages\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOrdering Information\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePlease provide the required model, quantity, compressor model, refrigerant, oil type, discharge-line size, operating pressure and temperature, installation orientation and delivery destination.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor replacement applications, include photographs and measurements of the existing unit and available installation space.\u003c\/span\u003e\u003c\/p\u003e","brand":"HPEOK","offers":[{"title":"PKX-4022 - 1-3\/8 in ODF","offer_id":44650716463163,"sku":null,"price":46.0,"currency_code":"USD","in_stock":true},{"title":"PKX-4026 - 1-5\/8 in ODF","offer_id":44650716495931,"sku":null,"price":53.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/8920\/8123\/files\/ChatGPT_2026_10_21_09_55_32.png?v=1792547759"}],"url":"https:\/\/xiaxuecoldroom.com\/ru\/collections\/discharge-mufflers\/odf-connection.oembed","provider":"XIAXUE Refrigeration","version":"1.0","type":"link"}