KAIDELI GUSD Double-Side Blow Unit Cooler – 6 mm Fin Spacing

Sale price $366.00

Go kalles this summer with this vintage navy and white striped v-neck t-shirt from the Nike. Perfect for pairing with denim and white kicks for a stylish kalles vibe.

Model: GUSD401B
Add to Wishlist
Add to Compare

Availability: In stock
KAIDELI GUSD Double-Side Blow Unit Cooler – 6 mm Fin Spacing

KAIDELI GUSD Double-Side Blow Unit Cooler – 6 mm Fin Spacing

Description

KAIDELI GUSD Series Double-Side Blow Unit Coolers

The KAIDELI GUSD series provides a 6 mm fin-spacing option for cold-room projects requiring ceiling-mounted, double-side air discharge and electric defrost.

The range includes nine models, from GUSD401B to GUSD454EC. Published capacities at SC1, SC2 and SC3 allow you to compare performance across different reference conditions. Choose the model around the application’s cooling load and room layout, then confirm the final selection for your refrigerant and temperatures.

Key Features

  • Double-side airflow with ceiling mounting.
  • 6 mm fin spacing.
  • Electric coil and drain pan defrost.
  • Copper tubes with aluminium fins.
  • Hinged drain pan for maintenance access.

Applications

Consider the GUSD series for chilled or frozen storage projects where the selected operating conditions, moisture load and defrost strategy suit a 6 mm fin-spacing evaporator. Review air paths around shelving, stored products and work areas when planning the installation.

Cooling Performance and Airflow

Model SC1 (kW) SC2 (kW) SC3 (kW) Tube Volume (L) Catalog Fan Power (qty × W) Airflow (m³/h) Air Throw (m)
GUSD401B 2.74 1.93 1.40 2.2 1 × 180 3,420 8
GUSD451D 5.70 4.01 2.93 4.3 1 × 250 3,818 9
GUSD402C 8.32 5.86 4.28 6.5 2 × 180 6,420 8
GUSD452D 11.42 8.05 5.88 8.6 2 × 250 7,600 9
GUSD452E 13.29 9.36 6.83 10.8 2 × 250 7,380 9
GUSD453E 17.64 12.42 9.06 13.5 3 × 250 9,900 9
GUSD453EC 20.80 14.65 10.62 16.2 3 × 250 11,500 9
GUSD454E 24.41 17.19 12.52 18.9 4 × 250 13,300 9
GUSD454EC 27.09 19.08 13.93 21.5 4 × 250 14,200 9

Fan power is reproduced from the manufacturer’s power column. Confirm the final fan quantity and diameter against the approved model specification.

Capacity Rating Conditions

Rating Inlet Air Temperature Evaporating Temperature Relative Humidity Superheat
SC1 +10°C 0°C 85% 6.5 K
SC2 0°C −8°C 85% 5.2 K
SC3 −18°C −25°C 95% 4.6 K

These values describe reference test conditions. They do not establish a continuous operating-temperature range. Request a capacity selection for the actual refrigerant, room temperature and evaporating temperature.

Electric Defrost Specifications

Model Coil Heaters (kW × qty) Drain Pan Heaters (kW × qty) Total Installed Heater Load (kW)
GUSD401B 0.30 × 4 0.30 × 4 2.40
GUSD451D 0.30 × 8 0.30 × 4 3.60
GUSD402C 0.45 × 8 0.45 × 4 5.40
GUSD452D 0.50 × 8 0.50 × 4 6.00
GUSD452E 0.50 × 12 0.50 × 4 8.00
GUSD453E 0.65 × 12 0.65 × 4 10.40
GUSD453EC 0.70 × 12 0.70 × 4 11.20
GUSD454E 0.90 × 12 0.90 × 4 14.40
GUSD454EC 1.00 × 12 1.00 × 4 16.00

Published fan supply: 380 V / 3-phase / 50 Hz.
Published defrost heater supply: 220 V / single-phase / 50 Hz.

Total installed heater load is the calculated sum of the coil and drain pan heaters. It excludes fan power and does not represent continuous operating consumption.

Dimensions and Connections

Model Overall B × T × H (mm) Liquid / Suction Connection Ø (mm) Drain Connection Weight (kg)
GUSD401B 955 × 1160 × 421 12 / 22 G3/4 53
GUSD451D 955 × 1160 × 421 12 / 22 G3/4 58
GUSD402C 1555 × 1160 × 421 12 / 28 G3/4 87
GUSD452D 1555 × 1160 × 421 22 / 35 G3/4 92
GUSD452E 1555 × 1160 × 421 22 / 42 G1 97
GUSD453E 1855 × 1160 × 421 12 / 28* G1 120
GUSD453EC 2155 × 1160 × 421 22 / 35 G1 132
GUSD454E 2455 × 1160 × 421 22 / 42 G1 156
GUSD454EC 2755 × 1160 × 421 22 / 42 G1 169

Dimensions follow the manufacturer’s B × T × H convention. Check mounting positions, service access and drain routing against the installation drawing.

The GUSD453E connection sizes follow the published table; obtain factory confirmation before preparing the pipework.

How to Select Your Model

  1. Calculate the cooling load for the room and stored products.
  2. Define the refrigerant, room temperature and evaporating temperature.
  3. Compare capacity under the appropriate SC condition.
  4. Review humidity, door-opening frequency and the planned defrost schedule.
  5. Confirm airflow distribution, electrical requirements and installation dimensions.
Model

GUSD401B, GUSD451D, GUSD402C, GUSD452D, GUSD452E, GUSD453E, GUSD453EC, GUSD454E, GUSD454EC

Recently viewed products